ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2011-08-24
    Description: A comprehensive characterization program is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80 K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precise individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heatsink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stroke, drive frequency, and piston-displacer dc offset.
    Keywords: ENGINEERING (GENERAL)
    Type: In: IECEC '92; Proceedings of the 27th Intersociety Energy Conversion Engineering Conference, San Diego, CA, Aug. 3-7, 1992. Vol. 5 (A93-25851 09-44); p. 5.101-5.107.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: This paper provides a summary overview of the vibration characteristics of split Stirling cryocoolers of the Oxford type and describes means being developed to achieve vibration levels consistent with the exacting requirements of sensitive infrared spectrometer instruments currently under development for NASA applications. A key emphasis of the paper is on exploring both active and passive means of reducing the residual upper harmonics of the drive frequency that remain with nulled back-to-back compressor and displacer units. Vibration supression results, measured with JPL's unique six-DOF force dynamometer, are presented for an 80 K Stirling cooler.
    Keywords: ENGINEERING (GENERAL)
    Type: In: Advances in cryogenic engineering. Vol. 37B - Proceedings of the 1991 Cryogenic Engineering Conference, Univ. of Alabama, Huntsville, June 11-14, 1991 (A93-48578 20-37); p. 1019-1027.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: For redundant miniature Stirling-cycle cryocoolers in space applications, the off-state heat conduction down the coldfinger of one cooler is a parasitic heat load on the other coolers. At JPL, a heat flow transducer specifically designed to measure this load has been developed, and measurements have been performed on the coldfinger of a British Aerospace 80 K Stirling cooler with the tip temperature ranging between 40 and 170 K. Measurements have also been made using a transient warmup technique, where the warmup rates of the coldtip under various applied heat loads are used to determine the static conduction load. There is a difference between the results of these two methods, and these differences are discussed with regard to the applicability of the transient warmup method to a nonoperating coldfinger.
    Keywords: ENGINEERING (GENERAL)
    Type: In: Advances in cryogenic engineering. Vol. 37B - Proceedings of the 1991 Cryogenic Engineering Conference, Univ. of Alabama, Huntsville, June 11-14, 1991 (A93-48578 20-37); p. 1037-1043.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-19
    Description: The growing demand for long wavelength infrared and submillimeter imaging instruments for space observational applications, together with the emergence of the multiyear life Oxford University Stirling cycle cooler, has led to a rapidly expanding near term commitment to mechanical cryocoolers throughout the subkelvin to 150 K temperature range for long-life space missions. To satisfy this growing commitment, emerging cryocoolers must successfully address not only the input power, cooling power, and mass constraints of the spacecraft and instruments, but also the broad array of complex interface requirements that critically affect successful integration to the sensitive instrument detectors. Generic requirements are presented for each of the cryocooler requirement areas, which are then contrasted with the projected capabilities of emerging space cryocoolers. The degree of match is used to highlight both the strengths of existing technologies and the areas in need of increased development.
    Keywords: ENGINEERING (GENERAL)
    Type: Cryogenics (ISSN 0011-2275); 30; 233-238
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...