ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • ENGINEERING (GENERAL)  (3)
  • DNA replication  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Plant molecular biology 15 (1990), S. 457-464 
    ISSN: 1573-5028
    Keywords: chloroplasts ; DNA helicase ; DNA replication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract A DNA helicase activity was detected in extracts of purified chloroplasts from the SB-1 cell line of Glycine max and partially purified by column chromatography on DEAE cellulose, phosphocellulose, and single-stranded DNA cellulose. The chloroplast helicase has a DNA-dependent ATPase activity, and its strand displacement activity is strictly dependent upon the presence of a nucleoside triphosphate and Mg2+ or Mn2+. Strand displacement activity does not require a free unannealed single-strand or replication fork-like structure.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-5028
    Keywords: chloroplast ; DNA replication ; origin ; soybean ; two-dimensional gel electrophoresis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Chloroplast DNA replication was studied in the green, autotrophic suspension culture line SB-1 of Glycine max. Three regions (restriction fragments Sac I 14.5, Pvu II 4.1 and Pvu II 14.8) on the plastome were identified that displayed significantly higher template activity in in vitro DNA replication assays than all other cloned restriction fragments of the organelle genome, suggesting that these clones contain sequences that are able to direct initiation of DNA replication in vitro. In order to confirm that the potential in vitro origin sites are functional in vivo as well, replication intermediates were analyzed by two-dimensional gel electrophoresis using cloned restriction fragments as probes. The two Pvu II fragments that supported deoxynucleotide incorporation in vitro apparently do not contain a functional in vivo replication origin since replication intermediates from these areas of the plastome represent only fork structures. The Sac I 14.5 chloroplast DNA fragment, on the other hand, showed intermediates consistent with a replication bubble originating within its borders, which is indicative of an active in vivo origin. Closer examination of cloned Sac I 14.5 sub-fragments confirmed high template activity in vitro for two, S/B 5 and S/B 3, which also seem to contain origin sites utilized in vivo as determined by two-dimensional gel electrophoresis. The types of replication intermediate patterns obtained for these sub-fragments are consistent with the double D-loop model for chloroplast DNA replication with both origins being located in the large unique region of the plastome [17, 18]. This is the first report of a chloroplast DNA replication origin in higher plants that has been directly tested for in vivo function.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-13
    Description: A thermal model of the dewar and optical system of the Cryogenic Optical Test Facility at NASA-Ames Research Center was developed using the computer codes SINDA and MONTE CARLO. The model was based on the geometry, boundary conditions, and physical properties of the test facility and was developed to investigate heat transfer mechanisms and temperatures in the facility and in test mirrors during cryogenic optical tests. A single-arch, fused-natural-quartz mirror was the first mirror whose thermal loads and temperature distributions were modeled. From the temperature distribution, the thermal gradients in the mirror were obtained. The model predicted that a small gradient should exist for the single arch mirror. This was later verified by the measurement of mirror temperatures. The temperatures, predicted by the model at various locations within the dewar, were in relatively good agreement with the measured temperatures. The model is applicable to both steady-state and transient cooldown operations.
    Keywords: ENGINEERING (GENERAL)
    Type: Cryogenic Optical Systems and Instruments IV; Jul 10, 1990 - Jul 12, 1990; San Diego, CA; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.
    Keywords: ENGINEERING (GENERAL)
    Type: Cryogenic Optical Systems and Instruments IV; Jul 10, 1990 - Jul 12, 1990; San Diego, CA; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Description: A summary of the cryogenic testing of glass and metal mirrors performed at NASA Ames Research Center (ARC) and two other places is presented. Recent improvements to the ARC Cryogenic Optics Test Facility are described. The purposes of the tests were to determine: (1) how glass mirrors would perform at cryogenic temperatures compared with metal mirrors and (2) how various mirror mounts would affect the cryogenic performance of mirrors. Details of a cryogenic test of a 50 cm 'double arch', fused-silica mirror with a three-point mount and with a radially-compliant, flexured mount are given. Within the accuracy of the measurements, it was determined that the flexured mount did not induce appreciable distortion in the double arch mirror. Results of the cryogenic tests of a number of glass mirrors and two beryllium mirrors are included. The cryogenic distortion of the glass mirrors was found to be less than that for the beryllium mirrors. Within the accuracy of the measurements, no hysteresis was found in the glass mirrors. It was possible to measure hysteresis in one of the beryllium mirrors.
    Keywords: ENGINEERING (GENERAL)
    Type: Cryogenic Optical Systems and Instruments III; Aug 17, 1988 - Aug 19, 1988; San Diego, CA; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...