ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 15 (1994), S. 483-487 
    ISSN: 0197-8462
    Keywords: ELF magnetic field ; dosimetry ; electric field probe ; tissue conductivity ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Measuring internal induced electric fields in animals with a miniaturized probe involves a potential error related to the difference between the hole conductivity (σh) and the surrounding tissue conductivity (σt). Theory was developed to describe this phenomenon and checked by probe measurements in agar-filled petri dishes. The value measured in the hole is 2σt/(σh + σt) times the actual field in the tissue. For example, a probe hole in muscle, which is filled with blood, could yield a measurement only about 22% of the true value in the muscle. This potential source of error can be mitigated to some extent by not actually cutting a hole, by using a low-conductivity (e.g., 0.2 S/m) coupling medium in the hole, or by ensuring contact between the probe's electrodes and the tissue. © 1994 Wiley-Liss, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...