    Medical & biological engineering & computing 27 (1989), S. 365-370 
    ISSN: 1741-0444
    Keywords: EEG ; Epileptiform activity ; Expert system ; Production system ; Spike detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An expert system for the automated detection of spikes and sharp waves in the EEG has been developed. The system consists of two distinct stages. The first is a feature extractor, written in the conventional procedural language Fortran, which uses parts of previously published spike-detection, algorithms to produce a list of all spike-like occurrences in the EEG. The second stage, written in the production system language OPS5, reads the list and uses rules incorporating knowledge elicited from an electroencephalographer (EEGer) to confirm or exclude each of the possible spikes. Information such as the time of occurrence, polarity and channel relationship are used in this process. A summary of thedetected epileptiform events is produced which is available to the EEGer in interpreting the EEG. The performance of the expert system is compared with an EEGer using a 320s segment from an EEG containing epileptiform activity. The system detected 19 events and missed seven (false negative) which the EEGer considered epileptiform. There were no false positive detections.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...