ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Cutaneous thermoreceptor  (1)
  • Springer  (1)
  • Hindawi
  • Molecular Diversity Preservation International (MDPI)
  • MDPI Publishing
Collection
Publisher
  • Springer  (1)
  • Hindawi
  • Molecular Diversity Preservation International (MDPI)
  • MDPI Publishing
Years
  • 1
    ISSN: 1432-1254
    Keywords: Sweating ; Infrared irradiation ; Spectral region ; Cutaneous thermoreceptor ; Skin temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geography , Physics
    Notes: Abstract In an attempt to detect differences in the thermal effect of infrared irradiation of different wavelengths, transient sweating response to infrared irradiation in various spectral regions was examined. In Series 1, the ventral or dorsal surface of the nude subject was irradiated repetitively for a period of 4 min (2 min on, 2 min off) by each of three kinds of infrared heaters with main emissivity in ‘near-infrared’ (NIR; 0.7–2.8 μm), ‘intermediate-infrared’ (MIR; 1.5–5.8 μm), and ‘far-infrared’ (FIR; 2.8–25 μm) regions. The sweating response on a non-irradiated area tended to be the greatest with MIR, while the magnitude of the sweating response on the irradiated area showed no consistent differences among various wavelengths. The results infer that MIR stimulated cutaneous thomoreceptors most effectively, while its direct effect on local sweat gland activity was minimal. In Series 2, the effects of 9–12 min irradiations in more restricted ranges of wavelength were compared by the combination of the three kinds of heaters with filters (translucent to wavelength ranges of 1.3–2.7, 2.7–3.5, 3.6–8.0 μm, respectively). The sweating response on a remote area was predominantly greater with the range of 2.7–3.5 μm than with the other wavelength ranges, while the local effect on sweating was minimal with this range. The results of Series 2 reinforce those of Series 1, indicating that the degree of stimulation of cutaneous thermoreceptors and of direct thermal effect on sweat gland activity differ with spectral regions incident on the skin, thus affecting local and remote effects on the sweating response.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...