ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 16 (1977), S. 231-246 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The interaction of water with collagenous tissue was investigated using dynamic mechanical spectroscopy and cryogenic X-ray techniques. The loss spectrum was found to be very sensitive to water which is highly associated with the macromolecule. Two water-sensitive loss peaks were observed below 0°C: the β2 or “water dispersion” at 150°K and the β1 at 200°K which is attributed to motion of polar side chains. Changes in peak temperature and intensity were not continuous with water content, but exhibited regimes in behavior which were associated with two types of nonfreezable water, structural and bound water. In cryogenic X-ray experiments, specimens which contained some freezable water exhibited reflections identified with the cubic form of ice. These ice crystals underwent an irreversible transition to the more common hexagonal form when warmed above 200°K. On the basis of these experiments, a model for the hydration of native collagenous tissue was proposed.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 16 (1990), S. 105-108 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A new type of SIMS instrument has been developed for submicron microarea analysis. The instrument is incorporated with an electron beam, which provides scanning electron microscopy (SEM) images of a sample. The operator determines the area to be analysed by observing the SEM image without damaging the sample, then switches the electron beam to an ion beam and carries out a SIMS analysis of that area. Electron and ion Beams with diameters of 〈20 nm and 〈70 nm, respectively, are focused on the sample. Some application data of the micro-area elemental analysis are presented.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...