ISSN:
0001-1541
Keywords:
Chemistry
;
Chemical Engineering
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
An investigation of the continuous chromatographic separation of an equimolar mixture of 1,3,5-trimethylcyclohexane and 1,3,5-trimethylbenzene with a 2.4 m × 1.37 cm ID vertical countercurrent moving bed is reported. The solid adsorbent was 30 mesh Al2O3, and the separation was carried out at 200°C. Steady-state axial concentration profiles of each species were determined by withdrawing vapor samples for analysis by gas chromatography. The binary mixture was continuously fed through a port located at approximately the midpoint of the column. The relative solids and carrier gas flow rates could be adjusted so that the more strongly adsorbed trimethylbenzene was transported downward, and less strongly adsorbed trimethylcyclohexane moved upward. For low feed rates, high-purity product streams of each were obtained at the bottom and top of the separator. For sufficiently high feed rates, trimethylbenzene was transported upward as well as downward, and top product purity deteriorated. This behavior is in qualitative accord with the predictions of a dispersionless, one-dimensional flow, adsorption equilibrium model incorporating a Langmuir isotherm.
Additional Material:
16 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/aic.690350505
Permalink