ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 12 (1979), S. 693-703 
    ISSN: 1612-1112
    Keywords: Detector characteristics ; Detector linearity ; Detection limit ; Dynamic range ; Sensitivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 12 (1979), S. 757-767 
    ISSN: 1612-1112
    Keywords: Detector characteristics ; Detector linearity ; Detection limit ; Dynamic range ; Sensitivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 25-27 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Instrumental modification to multidimensional separation ; Application with packed columns on complex sample composition ; Indene to pyrene range in coal tar ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 70-71 
    ISSN: 0935-6304
    Keywords: Statistically correct data treatment in chromatography, GC, LC, TLC ; Quantitative analysis ; Error propagation on peak area measurements and data pair technique ; Peak height evaluation is preferable, precise read out tools needed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 436-440 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; „bo“ data (starting peak width) in valveless multidimensional operation studied ; Heart cutting, trapping, re-injection effects measured ; Band broadening caused by connections small (160 ms2) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In order to permit valveless MDSS operation and easy column change, the hardware designed contains several connections. These can give rise to extra-column band broadening effects. In order to quantitate such effects, the packed-capillary column configuration (without trap) was used. The band broadening caused by the connections was found to be small: 120 ms2. A more practical approach was used to check the performance of the trap (re-injection) in the capillary-trap-capillary column configuration. Here the results obtained with re-injection from the trap were compared with results obtained in transfer and heart-cutting modes while the trap was heated. Re-injection was tested with n-alkanes ranging from n-C6 to n-C28. A starting peak width of 1.6 s was found.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 86-89 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed columns ; Multidimensional switching, MDSS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A multidimensional switching system with two packed columns has been used for the analysis of volatiles. Use of a high-boiling solvent and the backflush mode permitted total resolution of the mixture discussed in a short analysis time.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 166-168 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed columns ; Single compounds of special interest accurately analysed in multicompound mixtures ; Separation efficiency in MDSS separation multiplied, therefore often comparable to capillary GC separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methanol, 2-Me-propanol-2, propanol-2, benzene, toluene and xylenes in gasoline blends were determined using a valveless multi-dimensional switching system (MDSS) with two packed columns and temperature programming.Compounds of interest, interfering with paraffins and naphthenes, were in a sequence of four heart cuts transferred onto the second column. The resulting baseline separation enabled precise quantitative measurement within a short analysis time. Instrument settings, times of switching and integration parameters were stored in an instrument memory file (user table) and thus high precision in the measurements was achieved.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 206-207 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...