ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (2)
  • 1995-1999  (2)
  • 1
    ISSN: 0947-3440
    Keywords: Epoxides, C2-symmetrical ; Bisepoxides ; Butenolide, polyhydroxylated ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The enantiopure epoxides 2-6 were synthesized from 1,2;5,6-di-O-isopropylidene-D-mannitol (1). The terminal epoxides 2 and 3 are available from the desoxy mannitol 9 in three steps. The C2-symmetrical epoxides 4 and 5 were generated via the C-4-inverted alcohol 15. The C2-symmetrical bisepoxide 6 was prepared in a short sequence maintaining the symmetry throughout the entire synthesis. The crystalline butenolide 44 was prepared in five steps from 1 by Wittig olefination and lactonization.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Applied Organometallic Chemistry 12 (1998), S. 59-65 
    ISSN: 0268-2605
    Keywords: cobaltocenium ; ferrocene ; Nafion ; phenytoin ; phenobarbital ; square-wave voltammetry ; Chemistry ; Industrial Chemistry and Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two different cationic redox labels, i.e. a ferroceneammonium ion and a cobaltocenium ion, were covalently attached to two antiepileptics, phenytoin and phenobarbital, respectively. The two labeled drugs possess distinct standard redox potentials of 0.39 V for the phenytoin derivative and -0.92 V for phenobarbital derivative (vs Ag/AgCl, Cl- 0.05 M) at a carbon paste electrode. After preconcentration in a polyanionic Nafion-loaded carbon paste electrode the positively charged labeled phenytoin and phenobarbital derivatives could be simultaneously detected in concentration ranges which were relevant to the therapeutic ranges of the antiepileptics, with a view to a future dual-analyte immuno- assay. Square-wave voltammetry permitted detection limits of 5×10-8 M (for the phenytoin derivative) and 2.5×10-8 M (for the phenobarbital derivative) for non-simultaneous detection. © 1998 John Wiley & Sons, Ltd.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...