ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (5)
  • Cell & Developmental Biology  (1)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 133 (1987), S. 27-30 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Platelet-derived growth factor (PDGF) and PDGF-like polypeptides stimulate cell proliferation through paracrine and autocrine pathways. Each of these pathways is mediated by the PDGF receptor. Recently, cDNA clones for the receptor have been isolated and sequenced. The receptor gene on chromosome 5 is transcribed into a single 5.2 kb mRNA. The translated product, which is processed through at least one identifiable precursor, is expressed at the cell surface and is rapidly degraded. When activated by PDGF, the receptor mediates a group of diverse intracellular reactions. The receptor domains that mediate tyrosine kinase activity can be identified in the amino acid sequence of the receptor. However, the domains that mediate other PDGF-stimulated responses, such as turnover of phosphatidylinositol and enhanced expression of the c-myc and c-fos genes, have not been determined. Recently, a full-length receptor cDNA clone has been expressed in cells that normally lack PDGF receptors. This expression system should provide an approach to studies of the function of specific receptor domains and should help determine the relationship among the intracellular reactions stimulated by PDGF.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2005-11-13
    Description: Clean room air contamination monitoring techniques at Marshall Space Flight Center Manufacturing Engineering Laboratory
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: SANDIA CORP. CONTAMINATION CONTROL- CURRENT AND ADVANCED CONCEPTS IN INSTRUMENTATION AND AUTOMATION SEP. 1967; P 188-197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-05-29
    Description: Automatic aerosol particle counter for measuring airborne contamination level in controlled environment
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-X-53416
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-06-27
    Description: An acoustical transducer calibrating system includes a differential pressure actuating device having an inner chamber for applying differential pressures to the transducer, and an outer chamber for vacuum sealing. Mounted within the inner chamber is an electrostatic actuator for exciting the transducer at selected frequencies so that its sensitivity can be determined for different operating ambient pressures.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-27
    Description: The turbulent boundary layer on the wall of a 9 by 7 foot wind tunnel was measured with 12 different transducers at Mach numbers of 1.6, 2.0, and 2.5. The results indicated that the wall surface-pressure-fluctuation field was more homogeneous at a Mach number of 2.5 than at Mach numbers of 1.6 or 2.0. A comparison of power-spectral-density data at Mach 2.5 with a summary of similar data (Mach 0.1 to 3.45) showed good agreement. The measurement uncertainty was greatest when frequencies were low and the surface-pressure-fluctuation field was homogeneous. The uncertainty at higher frequencies increased as the surface-pressure-fluctuation field became more inhomogeneous. Since transducer mounting effects and system noise levels were determined not to have contributed appreciably to measurement uncertainties, the result was attributed to an interaction between the surface-pressure-fluctuation field and the transducers. Corcos' correction for size effects improved the comparison between transducers at the high frequencies, but did not eliminate an apparent size effect at the lower frequencies.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TN-D-7087 , H-700
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-06-27
    Description: Test program for electronic monitoring of airborne particule contamination in clean rooms
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-X-53881 , MSFC-R-ME-IN-67-1
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...