ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 13 (1973), S. 73-82 
    ISSN: 1432-0827
    Keywords: Bone ; Apatite ; Hydroxide ; Carbonate ; Infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé L'étude de spectres infra-rouges montre que le minéral osseux de jeune rat et les apatites synthétiques, formés à des pH, force ionique et température physiologiques sont très déficients en ion OH; ces apatites biologiques et synthétiques présentent d'importants défauts internes de maille. En outre, une proportion significative des ions CO3 2- de mineral osseux de rat est structurée de façon lâche dans un environnement amorphe ou superficiel. Les ions carbonate dans l'os chauffé sous vide ou dans les apatites synthétiques formés à pH physiologique paraissent être situés dans des environnements locaux multiples. Le CO3 2- contenu dans ces structures peut se substituer dans des positions PO4 3- et (à un degré moindre) OH−, bien que des variations importantes de ou dans ces positions sont dues à des défauts de maille. Les carbonato-apatites, formés par transformation thermique (600o) de phosphates calciques amorphes et contenant 4–9% de CO3 2-, présentent surtout du CO3 2- dans des environnements OH−. Une recristallisation thermique des apatites biologiques et synthétiques, dans une atmosphère d'air, augmente le contenu en OH− et redispose les positions CO3 2-. Cependant, de telles formations bien cristallisées sont différentes des précurseurs apatitiques.
    Abstract: Zusammenfassung Die Infrarotspektroskopie ergab, daß sowohl natives Rattenknochenmineral als auch synthetische Apatite, welche bei physiologischem pH, Ionenstärke und Temperatur gebildet wurden, an Hydroxydionen stark defizient sind. Es ist ebenfalls ersichtlich, daß diese biologischen und synthetischen Apatitkristalle beträchtliche innere Verzerrungen aufweisen (Gitterdefekte). Weiterhin zeigt ein bedeutender Anteil der CO3 2--Ionen im Rattenknochenmineral eine lockere Struktur in amorpher Umgebung oder an der Oberfläche. In Vakuumerhitzem Knochen oder in synthetischen Apatit (mit physiologischem pH), welches in der Lösung gebildet wurde, scheinen sich die Carbonationen in verschiedenen Umgebungen zu finden. CO3 2- im Inneren dieser Stoffe kann in PO4 3--und (in viel kleineren Mengen) OH−-Positionen ausgetauscht werden, obwohl eine beträchtliche Abweichung von und innerhalb dieser Stellen wahrscheinlich auf Gitterdefekte zurückzuführen ist. Carbonat-Apatite, welche durch die thermische Umwandlung (600°C) von 4–9% CO3 2- enthaltendem amorphem Calciumphosphat gebildet wurden, zeigen in erster Linie in OH−-Umgebung CO3 2-. Die thermische Umkristallisierung von biologischen und synthetischen Apatiten in einer Luftatmosphäre erhöht den OH−-Gehalt und verteilt die CO3 2--Lokalisationen neu. Solche sehr schön kristallisierten Produkte spiegeln jedoch durchaus nicht ihre nativen Apatitvorbilder wider.
    Notes: Abstract Infrared spectral data indicate that both native rat bone mineral and synthetic apatites formed at physiological pH, ionic strength and temperature are extensively deficient in hydroxide ion content; the data also indicate that these biological and synthetic apatites contain considerable internal distortions (lattice defects). In addition, a significant portion of the CO3 2- ions in rat bone mineral is loosely-structured in either an amorphous or surface environment. Carbonate ions in vacuum-heated bone or solution-ripened synthetic (physiological pH) apatites appear to be in multiple local environments. Internal CO3 2- in these materials may be substituted in PO4 3- and (in much lesser amounts) OH− positions, although considerable deviation from or within these sites is probable due to lattice defects. Carbonateapatites produced by thermal conversion (600o) of amorphous calcium phosphates containing 4–9% CO3 2- exhibit CO3 2- mainly in OH− environments. Thermal recrystallization of biological and synthetic apatites in an air atmosphere increases OH− content and reorganizes CO3 2- locales. However, such extremely well-crystallized products are not at all representative of their native apatitic precursors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0827
    Keywords: Acid phosphate ; Apatite ; Carbonate ; Pyrophosphate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Le rapport molaire Ca/P, % CO 3 2− et % HPO 4 2− sont déterminés pour un certain nombre d'apatites préparés par hydrolyse de phosphate de calcium amorphe en présence de solution de carbonate. Le rapport molaire Ca/P pour chaque apatite est significativement plus élevé que celui du précurseur amorphe correspondant. Le changement en contenu de carbonate est faible, mais la concentration en HPO 4 2− de ces apatites, déterminée selon la technique pyrolytique habituelle, est nettement réduite, et atteint souvent une valeur nulle. L'analyse infra-rouge montre, d'autre part, une concentration appréciable de HPO 4 2− . Il semble que le carbonate réagit au cours de la pyrolyse avec HPO 4 2− soit en bloquant une condensation de P2O 7 4− ou en dégradant du P2O 7 4− déjà formé. Il apparait qu'il faut utiliser la méthode de pyrolyse avec prudence pour déterminer la présence de HPO 4 2− dans les tissus calcifiés.
    Abstract: Zusammenfassung Das molare Ca/P-Verhältnis sowie die prozentualen Anteile von CO 3 2− und HPO 4 2− wurden bei einer Anzahl von Apatiten bestimmt, welche durch Hydrolyse von amorphem Calciumphosphat, bei Anwesenheit von Karbonat in der Lösung, erhalten wurden. Das molare Ca/P-Verhältnis war bei jedem Apatit bedeutend höher als bei der entsprechenden amorphen Vorstufe. Das Karbonat veränderte sich wenig, jedoch war der HPO 4 2− -Gehalt dieser Apatite, mittels der pyrolytischen Standard-Technik bestimmt, stark reduziert und lag manchmal nahe beim Nullwert. Andererseits zeigte die Infrarot-Analyse eindeutig einen beträchtlichen HPO 4 2− -Gehalt. Somit wird bewiesen, daß Karbonat die pyrolytische Bestimmung von HPO 4 2− stört, entweder indem es die Kondensation zu P2O 7 4− blockiert oder schon gebildetes P2O 7 4− abbaut. Es wird vorgeschlagen, daß die pyrolytische Methode zur Bestimmung von HPO 4 2− in verkalktem Gewebe nur mit großer Vorsicht anzuwenden ist.
    Notes: Abstract The Ca/P molar ratio, % CO 3 2− , and % HPO 4 2− was determined for a number of apatites prepared by the hydrolysis of amorphous calcium phosphate in the presence of solution carbonate. The Ca/P molar ratio for each apatite was significantly higher than for the corresponding amorphous precursor. The change in carbonate content was slight but the HPO 4 2− level in these apatites, as determined by the standard pyrolytic technique, was greatly reduced, sometimes to a near zero value. Infrared analysis, on the other hand, clearly showed an appreciable level of HPO 4 2− . Evidence obtained indicated that the carbonate interferes with the pyrolytic assay for HPO 4 2− by either blocking condensation to P2O 7 4− or by breaking down already formed P2O 7 4− . It is suggested that the pyrolytic method be used with great caution in assaying for HPO 4 2− in calcified tissue.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...