ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Capillary array electrophoresis  (1)
  • Electronics and Electrical Engineering  (1)
  • 1
    ISSN: 0173-0835
    Keywords: Capillary array electrophoresis ; Short tandem repeat ; Energy transfer primers ; Microsatellites ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Short tandem repeat regions (STRs) from the polymorphic loci VWFA, THO1, TPO and CSF were amplified by the multiplex polymerase chain reaction (PCR) and analyzed by capillary array electrophoresis with fluorescence detection of energy transfer (ET) labels. The fluorescent ET primers are labeled with one fluorescein at the 5′ end and a second fluorescein at the position of the 7th or 9th (modified) base to produce fragments that fluoresce in the green (λmax = 525 nm). M13 A-track sequencing fragments, used as an internal sizing standard, were generated with a universal primer that has a donor fluorescein at the 5′ end and a rhodamine acceptor at the position of the 11th (modified) base to produce fragments fluorescing in the red (〉 590 nm). The labeled DNA fragments were excited at 488 nm, and the fluorescence was detected with a two-color confocal fluorescence scanner. Separations were performed on arrays of hollow fused silica capillaries filled with denaturing and replaceable hydroxyethyl cellulose sieving matrices. Separations were complete in less than 50 min, and single base resolution as well as reproducible STR sizing was achieved. The relative standard deviation in sizing was below 0.6%. This work establishes the feasibility of high-resolution, high-speed and high-throughput STR typing of single-stranded DNA fragments using capillary array electrophoresis.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: The MOD (Mars Organic Detector) instrument concept consists of a sublimation apparatus for organic compound isolation connected to a microfabricated microfluidic analyzer containing a sipper, pumps and a separation channel for organic compound characterization. The target organic compounds are amino acids and polycyclic aromatic hydrocarbons (PAHs). Solid samples are placed within the sublimation apparatus and heated to release organic compounds which sublime onto a cold finger. Half of the cold finger is coated with fluorescamine. which reacts with amino acids and other primary amines to generate an intense fluorescent derivative while the other half is uncoated and is used to directly detect PAH fluorescence, A capillary sipper is then used to dissolve and sample the labeled amino acids and integrated microfabricated pumps transport the labeled amino acids to the chip for analysis. The sample is separated using capillary zone electrophoresis (CZE) together with chiral dextrins to determine amino acid composition and chirality. During the grant period, the following steps have been completed toward the development of a robust instrument and chemistry.
    Keywords: Electronics and Electrical Engineering
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...