ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Capillary GC  (6)
  • Wiley-Blackwell  (6)
  • American Chemical Society
  • Macmillian Magazines Ltd.
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 797-802 
    ISSN: 0935-6304
    Keywords: Capillary GC ; GPC and HPLC sample preparation ; Automation ; Planar chlorobiphenyls ; Horse fat ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The occurrence of the highly toxic non-ortho substituted (planar) chlorobiphenyls (CBs) at low levels in wildlife, (human) fat, and fish generates the need for a routine analytical procedure. The use of a fully automated system for the separation of planar and non-planar CBs, consisting of a gel permeation chromatography system, a sample preparation system employing extraction columns, and a porous graphitic carbon HPLC column is described, and tested with horse fat. Gas chromatography on capillary columns, with electron-capture or high resolution mass spectrometric detection, is used for quantitation of the CBs.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Capillary GC ; Continuous liquid-liquid extraction ; Environmental applications ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability of a liquid-liquid extraction system which is coupled on-line with a capillary gas chromatograph was studied for environmental and ecotoxicological analyses. The optimized and automated system was used for the determination of apolar and rather non-volatile organic compounds in aqueous samples. Relevant aspects of sample introduction, phase separation and selection of extraction solvent are discussed. Three routine-tipe applications are described, viz. an improved method for the determination of hexachlorocyclohexanes in ground water and the determination of the so-called NCC-ether and ACC-ether in ecotoxicological studies. Depending on the application studied, the concentration levels varied from 0.1 to 6000 μg/I, using ECD and/or FID detection. Typical coefficients of variation obtained with the total extraction-GC procedure were 2-25%.The system was found to be rugged, it saves time compared with set-ups involving off-line liquid-liquid extraction and considerably reduces the manual work load.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Capillary GC ; Coupled LC-GC ; Large injection volumes ; Trace analysis ; Aqueous samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes the design of a new, versatile, and low-cost on-line LC-GC interface that allows the fast and reliable introduction of large sample volumes onto a capillary GC column. The sample introduction procedure consists successively of: evaporation of the entire sample (LC fraction), selective removal of the solvent and simultaneously cold-trapping of the solutes, splitless transfer of the solutes to the GC column, on-column focusing, GC separation and detection. Quantitative and qualitative aspects of various experimental parameters are evaluated and optimum conditions are reported. The applicability of the method is demonstrated on a synthetic aqueous sample of chlorinated pesticides.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 785-790 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Derivatization ; (Chloro)alkyl chloroformates ; Non-aqueous reaction media ; Aqueous reaction media ; Fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fatty acids can be conveniently derivatized in less than one minute with (chloro)alkyl chloroformates such as methyl chloroformate, 2-chloroethyl chloroformate and 2,2,2-trichloroethyl chloroformate. 2,2,2-Trichloroethyl chloroformate is the most reactive reagent, and yields a reaction product which can be sensitively detected by GC ECD (detection limit 50 ng/ml, i.e. 25 pg/injection, for C8, C10, and C12 acids).In non-aqueous media 3-picoline, N-methylpiperidine, and dimethylaminopyridine show catalytic activity comparable with that of pyridine and can, therefore, replace it. N-methylpiperidine is the best basic catalyst in aqueous media (i.e. media containing up to 40 % water).
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 447-450 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Atomic emission ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Capillary GC ; On-line extractive alkylation ; On-line acylation ; Carboxylic acids ; Amines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatographic procedures are described for the determination of carboxylic acids and chlorinated anilines in water samples.Propionic acid and 2,6-difluorobenzoic acid in aqueous solution have been simultaneously alkylated and extracted by means of a continuous two-phase reaction system, and then quantitated by on-line coupled capillary gas chromatography; tetrahexyl-ammonium hydrogen sulfate was used as phase transfer catalyst and pentafluorobenzyl bromide as reagent.A factorial design approach was used to optimize on-line derivatization of aqueous propionic acid with regard to pH and concentration of phase transfer catalyst. Alkylation and extraction, under optimized conditions, followed by quantitation of the pentafluorobenzyl ester by flame ionization detection furnished a linear calibration for concentrations between 0.1 and 10 μg/ml. The relative standard deviation was 9-15 %.The continuous two-phase reaction system was also used to determine (chlorinated) anilines present in water at concentrations of 0.1-1 μg/ml; pentafluorobenzoyl chloride was used as reagent and analysis was performed by capillary gas chromatography with flame ionization or electron capture detection. The on-line acylation of p-chloroaniline was optimized with regard to pH, reagent concentration, and reaction time.The on-line reaction system worked satisfactorily for both applications, although excess reagent caused some problems with the chromatography.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...