ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Capillary, glass  (1)
  • Wiley-Blackwell  (1)
  • American Chemical Society
  • 1980-1984  (1)
  • 1920-1924
  • 1905-1909
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 241-247 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Capillary, glass ; Quantitative analysis at 10-10g level ; Steroids in urine ; Amino acid fluorobutyrates (19 in 35 min) ; Installation of glass capillaries ; Connection to FM-ECD ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Glass capillary columns are ideal for analysis of urinary steroid profiles (i.e. the total steroid neutral fraction without prior separation into sub-groups).In this paper performance of both SCOT and wide-bore WCOT columns has been compared, resulting in no significant quantitative difference on urine extracts run as trimethylsilyl ether derivatives. However, because of increased efficiency the WB-WCOT column exhibited more sensitivity in measurement of small amounts of 11-ox-aetiocholanolone. Sensitivity of other steroids was greatly enhanced by use of either SCOT or WB-WCOT, leading to an almost tenfold increase over conventional packed columns (e.g. androsterone and aetiocholanolone 〈 40 μg per 24 h urine sample). A simple splitless injection system (based on a design of Dr. W. Greenaway, Oxford University) is presented.Experiments were also carried out using a SCOT column in conjunction with an FM-electron capture detector. Whilst efficiency was impaired due to the design of the detector, use of He (carrier) and N2 (make up gas) showed that several steroid derivatives could be easily measured at well below the 10-10 g level with much more rapid retention times than with a 1½m packed column. Highly successful separation of 19 amino acids (as fluoro-acyl derivatives) was achieved in 35 minutes using a SCOT (30 m) SP2100 column.
    Zusätzliches Material: 12 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...