ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 17 (1995), S. 425-432 
    ISSN: 0392-6737
    Keywords: Biophysical instrumentation and techniques
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Summary Four e-beam-processed, planar electrodes with gaps between 0.5 and 4 μm were used to create quadrupole electric-field trap. The electrodes were immersed in an aqueous particle suspension and driven by kHz to MHz signals of several volts amplitude. Micron and submicron particles could be stably trapped by negative dielectrophoresis. Latex beads of 1000, 600, 100 and 14 nm diameter could be concentrated between the electrodes (positive dielectrophoresis) or levitated as condensed cloud (negative dielectrophoresis). The results are surprising since polarisation forces depend on the volume of the particle and, up to now, it was expected that thermal forces would dominate the behaviour of particles with diameters 〈100 nm. However, micron-scaled electrode configurations allow the application of extremely strong fields (up to 20 MV/m) and open up new perspectives for microparticle handling and macromolecule trapping.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...