ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 968-980 
    ISSN: 0173-0835
    Keywords: Matrix assisted laser desorption ; ionization mass spectrometry ; Capillary high performance liquid chromatography ; Protein sequencing ; Ion trap-mass spectrometry ; Protein identification ; Peptide mass mapping ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: In the search for novel nuclear binding proteins, two bands from a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gel were analyzed and each was found to contain a number of proteins that subseqently were identified by tandem mass spectrometry (MS/MS) on a quadrupole ion trap instrument. The bands were digested with trypsin in situ on a polyvinylidence difluoride (PVDF) membrane following electroblot transfer. Analysis of a 2.5% aliquot of each peptide mixture by matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) followed by an intial database search with the peptide mases failed to identify the proteins. The peptides were separated by reversed-phase capillary high performance liquid chromatography (HPLC) in anticipation of subsequent Edman degradation, but mass analysis of the chromatographic fractions by MALDI-MS revealed multiple, coeluting peptides that precluded this approach. Selected fractions were analyzed by capillary HPLC-electropspray ionization-ion trap mass spectrometry. Tandem mass spectrometry provided significant fragmentation from which full or partialsequence was deduced for a number of peptides. Two stages of fragmentation (MS3) were used in one case to determine additional dequence. Database searches, each using a single peptide mass plus partial sequence, identified four proteins from a single electrophoretic band at 45 kDa, and four proteins from a second band at 60 kDa. Many of these proteins were derived from human keratin. The protein identifications were corroborated by the presence ofmultiple matching peptide masses in the MALDI-MS spectra. In addition, a novel sequence, not found in protein or DNA databases, wes determined by interpretation of the MS/MS data. These results demonstrate the power of the quadrupole ion trap for the identification of multiple proteins in a mixture, and for de novo determination of peptide sequence. Reanalysis of the fragmentation data with a modified database searching algorithm showed that the same sets of proteins were identified from a limited number of fragment ion masses, in the absence of mass spectral interpretation or amino acid sequence. The implications for protein identification solely from fragment ion masses are discussed, including advantages for low signal levels, for a reduction of the necessary interpretation expertise, and for increased speed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0173-0835
    Keywords: Two-dimensional polyacrylamide gel electrophoresis ; Matrix-assisted laser desorption ; ionization - time of flight ; Peptide mass mapping ; Protein identification ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A number of proteins from a silver-stained two-dimensional (2-D) electrophoresis gel of mouse liver whole-cell lysate were identified by peptide mass mapping and sequene database searching. The excised protein spots were processed by in situ reduction and alkylation, followed by Lys-C digestion. The masses of the resulting peptide mixtures were measured with a matrix-assisted laser desorption/ionization (MALDI) reflectron-time-of-flight mass spectrometer. These masses were used successfully to search a protein sequence database. Optimized silver staining and digestion protocols allowed proteins to be identified routinely at the low picomole level. The high mass accuracy and resolution provided by delayed extraction were important for high specificity in the database search. Fragment ion data obtained by MALDI post-source decay (PSD) measurements not only provided confirmation of peptide identification, but could be used to identify the protein from a single peptide without spectral interpretation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...