ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0006-3592
    Keywords: aqueous two-phase systems ; partitioning of peptides ; liquid-liquid phase equilibrium ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Buffered aqueous two-phase systems are effective extraction systems for separating amphoteric hydrocarbons like, for example, polypeptides from aqueous phases. The design and basic engineering of such processes requires the knowledge of the liquid-liquid equilibrium. The study presented here aims to contribute to the development of methods to predict the partitioning of peptides in aqueous two-phase systems. Experimental results are reported for the partitioning of small amounts (≈0.001 g solute per gram of solution) of low molecular combination peptides of glycine, L-glutamic acid, L-phenylalanine, and L-lysine (9 dipeptides, gly-glu, gly-phe, gly-lys, glu-gly, phe-gly, phe-glu, lys-gly, lys-glu, lys-phe; 7 tripeptides, gly-gly-phe, gly-phe-gly, glu-gly-phe, phe-gly-gly, lys-gly-lys, lys-glu-gly, lys-phe-lys) in aqueous two-phase systems of high molecular weight dextran (molecular weight about 500,000) and poly(ethylene glycol) (molecular weight about 6,000 and 35,000, respectively) in the presence of small amounts (about 0.05 mol/kg) of K2HPO4/KH2PO4 buffer at about 293 K. The new data are compared to predictions. Partition coefficients are predicted applying a group contribution excess Gibbs energy model. The model is an osmotic virial equation. It uses surface fractions to encounter for the probability of interactions between solutes. All model parameters were taken from the literature. They were determined exclusively from experimental data for the phase forming systems and for the partitioning of amino acids and their di- and tripeptides (containing only a single amino acid), but no experimental data for the partitioning of combinations peptides were used. In most cases predicted partition coefficients agree favourably with the experimental data. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 60: 699-711, 1998.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 25 (1983), S. 19-32 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Pentosan hydrolysis at low aqueous liquid-to-biomass ratios (2.5-15 mL/g) with sulfuric acid as the catalyst is studied in the temperature range of 125-155°C. To facilitate heat transfer and mixing a second insoluble oil is added to the reaction mixture. It is found that even at high slurry concentrations, the reaction is the rate-controlling step. In addition, such systems give higher pentosan yields compared with dilute slurry systems. This is explained using the concept of acid loading which is defined as the acid present per unit mass of biomass.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Electric birefringence imaging (EBI) maps stresses in agarose electrophoresis gels. Both DNA and gel alignment can be monitored using this technique. Previously, we have reported birefringence images associated with resolved small (〈 48 kbp) and partially resolved large 48 kb - (2 Mbp) DNA fragments oriented with relatively short electric field pulses. In this paper, differences between images acquired using short and long (DC) voltage pulses are presented. It is shown that stress signals distribute over long distances when exposed to prolonged electric fields. Resolution also affects band shapes. Refinements in instrumental design and evaluation of limiting noise sources of the technique are also described.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...