ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 51 (1996), S. 15-22 
    ISSN: 0006-3592
    Keywords: preparative separation ; continuous ; free-flow zone electrophoresis ; electrophoretic mobility ; net charge ; enzymes ; proteins ; crude extract ; cell debris ; Candida boidinii ; Escherichia coli ; formate dehydrogenase ; formaldehyde dehydrogenase ; methanol oxidase ; β-galactosidase ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Continuous, single-step, state-of-the-art preparative separations of enzymes from microorganism crude extracts by free-flow zone electrophoresis are presented. In the first example, the enzymes formate dehydrogenase, formaldehyde dehydrogenase, and methanol oxidase were continuously separated from Candida boidinii crude extract. Yields of 85% to 95% and purification factors between 3 and 7 were obtained along with a simultaneous separation of the finer cell debris from the enzymes. Using multiple injections of sample, a throughput of 46.2 mg protein/h was recorded. In the second example, a fivefold purification of β-galactosidase from Escherichia coli was achieved along with complete, simultaneous cell debris separation from the enzyme. The yield of the enzyme was greater than 90%. The preparative free-flow zone electrophoresis experiments were run continuously for a period of 12 h and the separations were found to be stable; i.e., the enzymes and the cell debris eluted at their respective fraction numbers during the entire period. In both examples, choice of the type of buffer played a critical role and had to be investigated and optimized experimentally. Scale-up aspects of the separations are also discussed. Recently, by comparison of free-flow zone electrophoresis with ion-exchange chromatography, we have presented evidence that free-flow electrophoresis separations are governed by net surface charge (S. Nath et al., Biotechnol. Bioeng. 1993, 42: 829-835). Here, we offer further confirmation of this evidence by comparison of preparative free-flow zone electrophoresis experiments at various pHs on a mixture of two model proteins with analytical electrophoretic titration curves of the proteins. We are thus in a position to predict separations in free-flow zone electrophoresis. © 1996 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 3090-3093 
    ISSN: 0173-0835
    Keywords: Preparative electrophoresis ; Interval preparative isotachophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A new preparative electrophoretic method in free solution is described, consisting of three consecutive steps: (i) filling the separation chamber with a suitable electrolyte system and sample in parallel streams by laminar hydrodynamic flow, (ii) applying the voltage across the chamber with isotachophoretic separation for a definite time interval operating in the direction perpendicular to that of filling, (iii) reapplying a hydrodynamic flow (without voltage) and collecting the separated species via an array of outlets. This approach completely eliminates the main drawback of the continuous flow electrophoresis (CFE), i.e., the electrohydrodynamic distortion of zones. This method utilizes the instrumentation devised for CFE and enables the isolation of large amounts of individual sample species comparable to that of CFE, with a resolution comparable to that of capillary isotachophoresis. The precise timing of the consecutive steps in the procedure as well as the stability of the operational parameters are of key importance for reproducibility. By using cationic isotachophoresis with 3 synthetic pI markers as model sample species, the reproducibility, stability and the separation power of the newly presented method are demonstrated. The sample throughput corresponds to micromoles per hour.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 3094-3095 
    ISSN: 0173-0835
    Keywords: Preparative electrophoresis ; Continuous flow electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: The stability of continuous flow electrophoresis (CFE) was tested by performing uninterrupted continuous flow cationic isotachophoresis for 15 h, using a mixture of two synthetic isoelectric point (pI) markers as the model sample. This sample as well as the other operational electrolytes were continuously pumped into the CFE separation chamber via 10 individual inlets. The operational electrolyte system and the arrangement of the electrolyte streams were selected in accord with previously published results, providing a stable electrophoretic regime. The chamber had 96 individual outlets and here 96 individual fractions were collected in microwell plates in regular time intervals and scanned photometrically. The scanned photometric patterns proved that CFE is sufficiently stable for an overnight operation.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 1906-1910 
    ISSN: 0173-0835
    Keywords: Continuous flow electrophoresis ; Free flow electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Continuous flow electrophoresis (CFE) was optimized by employing (i) electrophoretic regimes with stacking properties, to eliminate electrohydrodynamic dispersion, (ii) quasi-mixed zones to prevent precipitation of the stacked analytes, (iii) sheath liquid streams at the electrode compartment membranes to prevent penetration of the electrode reaction products into the separation chamber, (iv) proper engineering of the separation chamber to provide efficient dissipation of Joule heat, and (v) counterflow at the collection outlets to eliminate the problems of dead volumes and uneven collection of separated species. Data on direct temperature measurements in the separation chamber at various levels of the dissipated electric power are presented. Preparative runs of amyloglucosidase in the isoelectric focusing (IEF) mode and rat liver organelles in the isotochophoresis (ITP) mode demonstrate the high performance of the optimized CFE system.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 1649-1653 
    ISSN: 0173-0835
    Keywords: Free flow electrophoresis ; Preparative electrophoresis ; Continuous isoelectric focusing ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Continuous flow electrophoresis (CFE) is a promising method for preparative fractionation of a variety of biological species, ranging from peptides and proteins to subcellular particles and cells. The high separation efficiency of FFE may be deteriorated by hydrodynamic distortion of zones due to the omnipresent parabolic laminar flow profile. We show in this paper that the detrimental hydrodynamic distortion of separated proteins zones can be reduced, with resultant enhancement of separation efficiency, by employing continuous isoelectric focusing in pH gradients as the actual working regime in an advanced instrumentation. Newly developed media for fast generation of narrow- or broad-range pH gradients under CFE conditions are described. The separation efficiency of these pH gradients is comparable to that of the gradients formed with the aid of synthetic carrier ampholytes. The new media are defined mixtures of nontoxic chemicals, and thus they are compatible with the requirements of human medicine. Experimental data are given showing that the new media offer fractionation of isoforms of proteins, that they offer resolution of proteins differing in isoelectric point (pI) by less than 0.05 pH units, and that these media inhibit proteins precipitation in experiments with human serum proteins.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 16 (1995), S. 92-97 
    ISSN: 0173-0835
    Keywords: Free flow electrophoresis ; Margin buffers ; Sodium chloride ; Mononuclear leukocytes ; Fura2-AM ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Free flow electrophoresis of cell suspensions in buffers containing sodium chloride was investigated using a modified procedure and the new apparatus Octopus PZE. The major methodical innovations are upward fluid flow margin buffers flowing through the electrophoresis chamber at both sides of a central cell suspension buffer, adjacent to the electrode membranes, and a sample injection device which focuses the cells hydrodynamically to the middle of the chamber thickness. Mononuclear leukocytes, suspended in a buffer containing 35 mM NaCl, could be fractionated with the same accuracy as by conventional free flow electrophoresis, operated with a single NaCl-free chamber buffer. However, testing the vitality of separated cells with the help of the calcium indicator FURA2-AM clearly demonstrated the biological importance of the presence of a minimum amount of sodium chloride during cell electrophoresis. Only if at least 35 mM NaCl were present could an undisturbed cytosolic Ca2+ metabolism be maintained for the time of a free flow electrophoresis cell separation experiment.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 526-528 
    ISSN: 0173-0835
    Keywords: Free flow electrophoresis ; Cell electrophoresis ; Margin buffers ; Sodium chloride ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Three buffer systems for free-flow electrophoresis have been designed, which proved useful for performing cell electrophoresis in the presence of 50 mM NaCl. Each system consists of one central cell suspension buffer with 50 mM NaCl, two margin buffers, and two electrode buffers. With the aid of a bromophenol blue/maxilon blue accumulation test the various buffers were adjusted to ensure a laminar flow and remain unchanged on their way through an electrophoresis chamber.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 1104-1109 
    ISSN: 0173-0835
    Keywords: Free-flow zone electrophoresis ; Hydrodynamic sample distortion ; Interval modus ; pH dependent sample focusing ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: On fractionation of highly heterogeneous protein mixtures, optimal resolution was achieved by forcing proteins to migrate through a preestablished pH gradient, until they entered a medium with a pH similar but not equal to their pIs. For this purpose, up to seven different media were pumped through the electrophoresis chamber so that they were flowing adjacently to each other, forming a pH gradient declining stepwise from the cathode to the anode. This gradient had a sufficiently strong band-focusing effect to counterbalance sample distortion effects of the flowing medium as proteins approached their isoelectric medium closer than 0.5 pH units. Continuous free-flow zone electrophoresis (FFZE) with high throughput capability was applicable if proteins did not precipitate or aggregate in these media. If components of heterogeneous protein mixtures had already started to precipitate or aggregate, in a medium with a pH exceeding their pI by more than 0.5 pH units, the application of interval modus and media forming flat pH gradients appeared advantageous.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0173-0835
    Keywords: Genetic toxicology ; Cancer risk assessment ; Mutagenesis ; Mutant analysis ; Restriction mapping ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: In genetic toxicology, the main fields of applications of the polymerase chain reaction (PCR) with subsequent electrophoretic characterization of amplificates include genotyping polymorphisms in the xenobiotic metabolism and mutant analysis. To assess the role of the individual sets of biotransformation enzymes for the internal dose resulting from xenobiotic exposure, we investigated blood samples from 69 healthy donors for the occurrence of known genetic polymorphisms in the xenobiotic metabolizing enzymes N-acetylaminotransfrase II (NAT2), glutathione-S-transferase (GST) μ and θ, and several cytochromes P450 (CYP), namely CYP1A1, CYP2E1 and CYP2A6. Using single strand conformation polymorphism (SSCP) analysis, five known single base substitutions located in the middle portion of 144 bp amplificates comprising exons 7 and 8 of the human hypoxanthine guanine phosphoribosyl transferase (hprt) cDNA, were clearly distinguished from wild type and from each other. Biomagnetic strand separation assigned the slower migrating single strand bands to the biotinylated sense strands.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 18 (1997), S. 2803-2810 
    ISSN: 0173-0835
    Keywords: Latex allergy ; Two-dimensional polyacrylamide gel electrophoresis ; Immunoblotting ; Protein microsequencing ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Two-dimensional (2-D) electrophoresis followed by immunoblotting and N-terminal protein microsequencing were used to characterize and identify the IgE-reactive proteins of Hevea latex that are the main cause of the latex type I allergy affecting especially health care workers and spina bifida children. This approach generated a comprehensive latex allergen database, which facilitated the integration of most of the latex allergen data presented in the literature. The major latex allergens Hev b 1, Hev b 3, Hev b 6 and Hev b 7 have been localized on our 2-D maps. Moreover, we were able to identify six previously undescribed IgE-binding latex proteins, namely enolase, superoxide dismutase, proteasome subunit C5, malate dehydrogenase, triosephosphate isomerase and endochitinase. The generated latex 2-D maps will provide valuable information to develop strategies for the isolation of the novel IgE binding proteins in order to study the frequency of sensitization among both risk groups. Detailed knowledge of all proteins involved in latex allergy will allow better diagnosis of latex allergy and to monitor the success of prevention strategies that are needed to reduce the high prevalence of latex allergy among both risk groups.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...