ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Protoplast vacuole  (2)
  • Best. von Selen in Kupfer  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/Bioenergetics 806 (1985), S. 311-319 
    ISSN: 0005-2728
    Keywords: (Barley) ; Energy dependence ; Malate uptake ; Protoplast vacuole
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2048
    Keywords: Hordeum (protoplast vacuole) ; Hydrolase ; Polypeptide ; Protoplast vacuole ; Tonoplast ; Vacuole sap
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Intact chloroplasts and vacuoles were isolated from mesophyll protoplasts of barley. The chloroplasts occupied about 15% of the cellular volume and contained 75% of the protein, whereas the vacuoles occupied about 80% of the volume and contained less than 4% of total cellular protein. Contamination of the vacuolar fraction by foreign protein is included in these values. Chlorophyll was absent from the vacuolar fraction, but less than 1% of several extra-vacuolar marker proteins were still present. The vacuoles contained hydrolytic enzymes. Several of them (α-mannosidase, α-galactosidase, N-acetylglucosaminidase) were soluble, whereas part of the activity of others semimented with the tonoplasts during centrifugation. Attached proteins could be released from the membranes during freezing in the presence of NaCl. One-dimensional gel electrophoretic separation of soluble vacuolar proteins under non-denaturing conditions yielded more than 10 protein bands. A comparative analysis was performed of thylakoids and vacuoles which were subfractionated into tonoplasts and soluble vacuolar constituents. Sodium dodecyl sulfate gel electrophoresis separated about 15 polypeptides of the soluble fraction which reacted with silver reagent. The tonoplast fraction yielded about 20 bands. A similar number of bands was observed when vacuoles incubated with the 14C-labelled SH-reagent N-ethylmaleimide were analysed for radioactive polypeptides. Silverstaining of the polypeptides and their SH-content did not correlate. Several polypeptides of the vacuolar fraction had molecular weights very similar to the molecular weights of known chloroplast proteins. However, with the exception of the two subunits of ribulose-1,5-bisphosphate carboxylase, contamination of the vacuolar fraction by chloroplast proteins could be ruled out as a possible cause of the close correspondence. The lipophilic carboxylic-group reagent N,N′-dicyclohexylcarbodiimide ([14C]DCCD) reacted with several polypeptides of thylakoids and tonoplasts. However, the labelling patterns were different. The most heavily labelled polypeptide of thylakoids was the 8-kDa polypeptide of the basal part of the coupling factor CF0. Tonoplast polypeptides heavily labelled with [14C]DCCD had molecular weights of 24, 28, and 56 kDa. The vacuolar 8-kDa polypeptide remained unlabelled.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 281 (1976), S. 201-209 
    ISSN: 1618-2650
    Keywords: Best. von Selen in Kupfer ; Chromatographie, Gas ; Reinstkupfer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung geringster Selengehalte in Reinstkupfer erhitzt man die Probe (≤2 g) in einem Quarzrohr im Sauerstoffstrom auf 1100–1150°C. SeO2 verdampft und wird quantitativ gesammelt, indem man es zusammen mit dem Trägergas durch Kühlung mit flüssigem Stickstoff in einer Mikrovorlage kondensiert. Nach Abdampfen des Sauerstoffs setzt man es in der Vorlage mit 4-Nitro-o-phenylendiamin zu 5-Nitropiazselenol um, das nach Ausschütteln in Toluol direkt gas-chromatographisch (ECD) im ppb-Bereich bestimmt wird. Nach Optimierung aller Verfahrensschritte mit Hilfe von 75Se ergaben sich ausgezeichnete Gütedaten; Standardabweichung: ± 0,004 ppm für 0,74 ppm Se, 15 Bestimmungen, 200–600 mg Einwaage; Nachweisgrenze : 1 ppb Selen.
    Notes: Abstract For the determination of the smallest amounts of selenium in high-purity copper, the sample (≤2 g) is heated in a quartz tube at 1100–1150°C. SeO2 evaporates and is collected quantitatively by condensation of the carrier gas in a micro-trap cooled with liquid nitrogen. After evaporation of the oxygen, SeO2 is caused to react in the trap with 4-nitro-o-phenylenediamine, forming 5-nitropiazselenol, which is then extracted with toluene and determined in the ppb-range by gas-chromatography with ECD. All separation steps were optimized by the tracer method using 75Se. Determining 0.74 ppm of Se, the standard deviation was found to be 0.004 ppm for 15 determinations with samples of 200–600 mg. The detection limit is 1 ppb of Se.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...