ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2011-08-16
    Description: Five patients were studied with left ventriculography during different phases of the Valsalva manoeuvre. Small doses of contrast medium allowed adequate repetitive visualization of the left ventricle for volume calculation. During strain phase, the volume of the left ventricle decreased by nearly 50 per cent in each case, and stroke volume and cardiac output also dropped strikingly. Release of straining was attended by a sharp rebound of left ventricular volume to control levels, with a transient surge of increased cardiac output 42 per cent above that of the resting state.
    Keywords: BIOSCIENCES
    Type: British Heart Journal; 36; July 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-16
    Description: Phonocardiographic and ultrasound observations of acute rejection following cardiac transplantation, considering rejection treatment at early stage
    Keywords: BIOSCIENCES
    Type: ; 39(
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-27
    Description: The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.
    Keywords: BIOSCIENCES
    Type: Circulation; 46; Sept
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-06-27
    Description: An experimental animal model with acute myocardial infarction of a size insufficient to produce profound heart failure or shock was used to study the effects of acute infarction on digitalis tolerance and the hemodynamic changes produced by moderate and large doses of acetylstrophanthidin. With acute myocardial infarction, digitalis toxic arrhythmias could be precipitated with significantly lower doses of digitalis than in animals without myocardial infarction. There was no precise correlation between the size of infarction and the toxic dose of glycoside. Coronary artery ligation produced a stable but relatively depressed circulatory state, as evidenced by lowered cardiac output and stroke volume and elevated systemic vascular resistance and left atrial mean pressure. When digitalis was infused, the following significant changes were observed at nontoxic doses: (1) elevation of aortic and left ventricular pressures; (2) further decline in cardiac output; and (3) decreased left atrial mean pressure.
    Keywords: BIOSCIENCES
    Type: American Journal of Physiology; 222; Feb. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-27
    Description: Three levels of decreased arterial oxygen saturation elicited a graded circulatory response in dogs, manifested by stepwise increases in cardiac output, left ventricular dp/dt, and stroke volume, and decreases in systemic vascular resistance. Responses to similar hypoxia challenges after experimental myocardial infarction were qualitatively similar but quantitatively less. Although the circulatory compensation for hypoxia was less effective after myocardial infarction, no further deterioration of the haemodynamics was noted.
    Keywords: BIOSCIENCES
    Type: Cardiovascular Research; 5; Oct. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-27
    Description: Mongrel dogs pulmonary and systemic circulatory responses to dopamine infusion
    Keywords: BIOSCIENCES
    Type: ; 47 (
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-27
    Description: Hemodynamic effect of lidocaine given by infusion and bolus injections in myocardial infarction, examining cardiac output, heart rate, systolic left ventricular and aortic pressures
    Keywords: BIOSCIENCES
    Type: ; 5, 6, 8 (
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-27
    Description: Serum calcium-digitalis synergism effect on dogs heart excitability, noting hypoxia role in arrhythmia production
    Keywords: BIOSCIENCES
    Type: ; STITUTION OF ENGINEE
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: Isoproterenol, atrial pacing, ouabain and methoxamine effects on dogs during experimental cardiac tamponade, observing arterial pressure, cardiac output and heart rate changes
    Keywords: BIOSCIENCES
    Type: ; ANSPORTURI AUTO, NAV
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: Echographic dimensions of the aortic root and left atrium were compared in 170 patients in order to assess dilation of the left atrium with reference to the relatively nondistensible fibrous aortic root. In 50 patients without cause for left atrial or aortic enlargement, the ratio of left atrial/aortic root dimensions was 0.87 to 1.11. In 80 patients with known cause for left atrial enlargement, the left atrial/aortic root ratio was greater than or equal to 1.17. In 40 patients with isolated valve disease, dilation of both the aortic root and the left atrium resulted in a left atrial/aortic root dimension ratio less than 1.17 in some patients. Despite this consideration, the comparison of left atrial and aortic root dimension appears to be as specific as, and more sensitive than, previously proposed methods for the evaluation of left atrial enlargement.
    Keywords: BIOSCIENCES
    Type: Circulation; 50; July 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...