Publication Date:
2022-05-25
Description:
This report describes the development of a Data Processing Module (DPM) designed for use with an RD Instruments Acoustic
Doppler Current Meter (ADCM). The DPM is a self-powered unit in its own pressure case and its use requires no modification to
the current meter. The motivation for this work was the desire for real-time monitoring and data transmission from an ADCM
deployed at a remote site. The DPM serves as an interface between the ADCM and a satellite telemetry package consisting of a
controller, an Argos Platform Transmit Terminal, and an antenna. The DPM accepts the data stream from the ADCM, processes
the data and sends out the processed data upon request from the telemetry controller. The output of the ADCM is processed by eliminating unnecessary data combining quality control information into a small number of summary parameters, and averaging
the remaining data in depth and time. For the implementation described here, eight data records of 719 bytes each, output from the
ADCM at 15 minute intervals, were processed and averged over 2 hr intervals to produce a 34 byte output array.
Description:
Funding was provided by the Office of Naval Research under
Contract No. N00014-89-J-1288.
Keywords:
Satellite telemetry
;
Acoustic Doppler Current Profiler
;
Argos
Repository Name:
Woods Hole Open Access Server
Type:
Technical Report
Format:
2616239 bytes
Format:
application/pdf
Permalink