    Journal of High Resolution Chromatography 8 (1985), S. 347-355 
    ISSN: 0935-6304
    Keywords: Simulation of chromatograms ; Data processing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A digital chromatogram simulator has been used to evaluate the performance of data handling systems. The simulator can synthesize chromatograms with any desired shape from a library of peaks based on real peak shapes. Once generated, the chromatograms can be reproduced exactly any number of times.The algorithms used in data handling systems have a significant effect on the results they produce. An object of this work was to examine how well the true size of a peak was reported when the peak was detected overlapping with other peaks. A series of experiments was therefore performed in which peaks were overlapped by different amounts and in different situations. The reported results from the data systems were compared with the results which would have been reported had the peaks been fully resolved. A significant difference was found between the overlap results and the fully resolved results, which did not have a linear relationship with the parameters tested.The chromatogram simulator was found to be a powerful tool in assessing the performance of the data systems. It offers a valuable means of evaluating the quality of the results produced by these systems.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 341-344 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Fused silica columns ; Peak splitting ; Christmas tree peaks ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fluctuating thermal gradients are recognized as a distinct source of peak splitting in capillary column gas chromatography. In this study, the influence of analyte signal level, temperature oscillation amplitude, and oscillation frequency on splitting are quantitatively examined. Stable gradients are also considered. A simple, effective method is proposed for virtually eliminating thermal peak splitting in isothermal capillary GC analysis.
    Additional Material: 7 Ill.