ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (23)
  • Wiley-Blackwell  (23)
  • American Institute of Physics
  • American Institute of Physics (AIP)
  • 1
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermospray LC/MS methods with internal standardization were developed for the quantification of the antimalarial arteether and six of its metabolites at the 1-10 μg/ml level in liver microsome preparations without the use of solvent extraction. The thermospray mass spectra of arteether and most of its metabolites exhibited strong [M + NH4]+ and [M - OR]+ peaks arising from the molecular ion adduct and the loss of the alkoxy or hydroxy group of the side chain. In addition to the six metabolites for which authentic reference standards were available, three additional metabolites were detected. The major metabolites of arteether were found to be dihydroartemisinin, deoxydihydroartemisinin, 3-hydroxydeoxydihydroartemisinin, two isomers of hydroxyarteether, and 3-hydroxydeoxyarteether. Deoxyartheether was not found at significant concentrations in the microsome preparation.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 150-150 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry has been used to measure accurately the molecular masses of synthetic methylphosphonate oligodeoxyribonucleotides, up to 18 nucleotides in length. A simple method has been developed for the complete sequence verification of these compounds, which are intractable by classical means. Sequencing from the 5′ end of the molecule is possible because of inefficiencies in the synthetic procedure. Complementary information from the 3′ end can be obtained by partial hydrolysis of the methylphosphonate backbone.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 211-213 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of octafluorotoluene (OFT) as a versatile gas chromatographic/mass spectrometric derivatizing agent for steroids containing alcoholic, phenolic or α,β-unsaturated keto functions, is described. Two distinct derivatizing schemes can be utilized, involving (method 1) a phase-transfer reaction, employing a two-phase system of CH2Cl2 and N NaOH with n-Bu4NHSO4 as catalyst (suitable for alcoholic and phenolic steroids) and (method 2) a reaction conducted in anhydrous dimethylformamide at 155°C with CsF as base (appropriate for α,β-unsaturated keto steroids). Perfluorotolyl (PFT) ethers and/or enol ethers have thus been generated. The electron impact spectra display abundant high-mass molecular ions where derivatization has occurred at a phenolic or enolic function. An extraction, derivatization and gas chromatographic/mass spectrometric scheme has been devised involving method 2 for the analysis of steroids in human plasma. A preliminary quantitative investigation of the levels of testosterone in plasma has been carried out employing these methods. The anomalously high level found is explained in terms of the presence in plasma of lipid-soluble derivatives of testosterone (probably fatty acid esters) which generate the testosterone bis-OFT derivative under the reaction conditions employed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The sequences of synthetically prepared methylphosphonate oligodeoxyribonucleotides have been verified using ionspray tandem mass spectrometry with sample introduction via flow injection. The technique involves the use of product-ion scans from multiply protonated (4+ and 5+) precursors. Among the ions detected are several series of fragments of different charge states that indicate the base sequence of the intact molecule. Oligomers as large as 18 bases have been successfully characterized.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1087-1094 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A pneumatically assisted electrospray liquid chromatography/mass spectrometry interface has been modified for use with open-tubular supercritical fluid chromatography (SFC). The modified interface houses the SFC flow restrictor within the spray device. A sheath-flow liquid of methanol or methanol/water containing ammonium acetate flows coaxially to the restrictor. The addition of the sheath-flow liquid results in the ionization of analytes known to be in a neutral charge state during the chromatographic separation. The sheath-flow liquid also allows for the independent operation of the chromatograph and the mass spectrometer. Both could be operated under optimum conditions. The operation of the interface was optimized using a solution of poly(dimethylsiloxane) in CO2 introduced by continuous infusion. We also report the application of the modified instrument to samples containing amines and propoxylated alcohols.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1990), S. 793-806 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Studies on the metabolism of the tricyclic antidepressant trimipramine, 5-(3-dimethylamino-2-methylpropyl)-10, 11-dihydro-5H-dibenz[b, f] azepine, in the rat are described. Many metabolites of trimipramine (TMP) were isolated from rat urine after enzymatic hydrolysis and their structures were identified by a gas chromatographic/mass spectrometric method, before and after appropriate chemical derivatization. Besides unchanged TMP, 20 metabolites were characterized (underivatized, and after acetylation), of which 12 had undergone alicyclic (C10 or C11) oxidation. This is a hitherto unreported metabolic pathway for TMP in the rat.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An assay for the determination of the neuromuscular blocking agents pancuronium bromide and vecuronium bromide in plasma or urine has been developed. This method is based on syringe application of sample extracts to the moving belt surface and single metastable transition monitoring of the elimination of acetic acid from the ion of m/z 543 during chemical ionization. The analysis shows good linearity over three orders of magnitude and is capable of analyzing for the compounds below the 5 ng ml-1 level. The assay has been used in preliminary pharmacokinetic studies of the biological fluids of surgical patients. The utility of the method for simultaneous determination of the deacetylated metabolites of these two drugs has also been investigated.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The thermospray mass spectra of arteether and 16 of its potential metabolites all showed strong [M + NH4]+ ions and with only a few exceptions these compounds also showed spectral peaks corresponding to [M + NH4 - HOR]+ and [M + H - HOR]+, where OR represents the alkoxy or hydroxy group at the 12-position. A method for quantifying the metabolites was developed in which the plasma was spiked with an internal standard (the propyl ether analog of arteether), extracted using a C-18 solid-phase cartridge, then subjected to thermospray high-performance liquid chromatographic/mass spectrometric analysis using selected ion monitoring and a C-18 reversed-phase analytical column. Following the intravenous administration of arteether (11.6 mg kg-1), the plasma was found to contain 12 metabolites of arteether in the 10-1000 ng ml-1 range 15 min post-injection, and within 60 min two of these metabolites attained higher concentrations than that of the parent compound, while several other of the metabolites attained concentrations similar to the parent compound. The pseudo-first-order half-life of arteether was found to be 10.0 ± 0.6 min, while the apparent half-lives of most of the metabolites were in the 15-30 min range. Nine of these metabolites were identified by comparison to authentic reference standards and the structures of three remaining metabolites were tentatively assigned from their spectral and chromatographic properties. The metabolic pathways leading to these 12 metabolites was a rather complex, multiple-step process, but most of the metabolites arose from an enzymatic oxidation at one of three sites; 3α, 9α, or the CH2 of the side-chain. Conversion of the endoperoxide group to an cyclic ether was not a major pathway. The in vitro antimalarial activity of reference standards of several of the metabolites was determined and all of those tested were found to be active in the low nanogram per milliliter range.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1076-5174
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A gas chromatographic/mass spectrometric/mass spectrometric method was developed for the determination of 5-methoxyflavone in plasma. Optimized detection schemes for 5-methoxyflavone readily allow a limit of quantification of 1 ng ml-1 in rat or dog plasma (1.0 ml sample volume). The complete analysis time (injection to injection) is less than 9 min and allows for rapid automated sample throughput. Additional advantages include a high degree of specifity and good accuracy and precision. This type of rapid tandem mass spectrometric assay has been found to be particularly useful in pharmaceutical discovery, since an assay for one compound can be quickly developed, utilized and then modified to determine analogs of similar structure. Application of this methodology to pilot preclinical pharmacokinetic studies of the drug indicated that it is rapidly absorbed and cleared, with an apparent terminal half-life of about 15 min in dogs. Bioavailability in the two dogs tested ranged 33 to 72%, but was about 25% in rats.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...