ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (22)
  • 1995-1999  (11)
  • 1985-1989  (11)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 2 (1988), S. 247-263 
    ISSN: 0886-9383
    Keywords: Calibration ; Tensor ; Multivariate ; PCR ; MLR ; PLS ; Regression ; Multidimensional arrays ; Order ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Many analytical instruments now produce one-, two- or n-dimensional arrays of data that must be used for the analysis of samples. An integrated approach to linear calibration of such instruments is presented from a tensorial point of view. The data produced by these instruments are seen as the components of a first-, second- or nth-order tensor respectively. In this first paper, concepts of linear multivariate calibration are developed in the framework of first-order tensors, and it is shown that the problem of calibration is equivalent to finding the contravariant vector corresponding to the analyte being calibrated. A model of the subspace spanned by the variance in the calibration must be built to compute the contravarian vectors. It is shown that the only difference between methods such as least squares, principal components regression, latent root regression, ridge regression and partial least squres resides in the choice of the model.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 2 (1988), S. 265-280 
    ISSN: 0886-9383
    Keywords: Calibration ; Tensor ; Multivariate ; Order ; Regression ; Generalized rank annihilation ; GRAM ; Multi order ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Tensorial calibration provides a useful approach to calibration in general. For calibration of instruments that produce two-dimensional (second-order) arrays of data per sample, tensoial concepts are as natural a way of solving the calibration problem as vectorial concepts are for the multivariate problem. Similarly, for third- and higher-order data, the tensorial description of calibration is also useful. This paper introduces second-order calibration from a tensorial point of view. Univariate, multivariate and bilinear approaches to calibration are presented. The generalized rank annihilation method (GRAM) is described from the tensorial perspective, and it is shown that GRAM is equivalent to finding a second-order tensorial base that spans both tensors (calibration and unknown) with respective diagonal component matrices. GRAM uses a single calibration sample for multicomponent analysis even in the presence of interference. Second-order bilinear calibration is extended to multiple calibration samples where the effect of collinearities is reduced.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 493-498 
    ISSN: 0886-9383
    Keywords: Rank annihilation ; Generalized rank annihilation method ; Generalized eigenproblem ; Calibration ; Spectral interferents ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An improved algorithm for the generalized rank annihilation method (GRAM) is presented. GRAM is a method for multicomponent calibration using two-dimensional instruments, such as GC-MS. In this paper an orthonormal base is first computed and used to project the calibration and unknown sample response matrices into a lower-dimensional subspace. The resulting generalized eigenproblem is then solved using the QZ algorithm. The result of these improvements is that GRAM is computationally more stable, particularly in the case where the calibration sample contains chemical constituents not present in the unknown sample and the unknown contains constituents not present in the calibration (the most general case).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The electron ionization-induced fragmentation pattern of extended tetrathiafulvalenes has been studied by exact mass measurements, metastable ion analysis and collision-induced dissociation mass spectrometry. The influence on the fragmentation of the central bridge linking the dithiole moieties is discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1075-4261
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: SERS, SERRS and NIR FTSERS of emodin and hypericin are reported for the first time on aqueous silver colloid. Intense SERRS spectra can be obtained when using excitation lines at 514 nm for emodin and 598 nm for hypericin. FTIR and NIR FTRaman spectra from these molecules and their model compounds, anthrone and bianthrone, were recorded to assist in the assignment of the SERS bands. From the analysis of the SERS spectra a different orientation for each molecule can be deduced. © 1995 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A system based on the EDAX 9100 analyser was developed to obtain concentration profiles. Even though the system can be used on any type of flat specimens, in this study it was used for measuring the tungsten (W) concentration on rough spherical specimens of the W-γ-Al2O3 supported catalyst. The concentration gradient of the active component from the periphery to the centre of the particle is often an important factor in determining catalyst performance. The purpose was to determine the concentration profile of W along the radius of a sphere with a large enough number of experimental points to draw accurate information in a short time. In this way, a considerable number of impregnated spheres can be analysed, and average results can be calculated and taken as representative values of the population under study. The method developed provides highly satisfactory results, making it very useful for the systematic study of this type of specimen. Obviously, the use of this system can be extended to metallurgical and mineralogical specimens.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 24 (1995), S. 221-225 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The synchrotron photoionization method was applied to measure L-subshell Coster-Kronig yields for Tb. This method is based on the capability of tuning the energy of the synchrotron photons producing a selective subshell ionization. A foil sample of Tb was irradiated and characteristic spectra were recorded. Data were analysed using a new formalism (based on a matrix representation) to express x-ray fluorescence intensities involving Coster-Kronig transitions. The results obtained were f12 = 0.201 ± 0.014, f13 = 0.281 ± 0.027 and f23 = 0.097 ± 0.016. These data represent valuable information for spectroscopists, considering the lack of data for L-shell parameters.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 111-116 
    ISSN: 0935-6304
    Keywords: Polynuclear aromatic hydrocarbons ; Liquid chromatography ; Alcohols ; Micelles ; Enviromental samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the separation of polycyclic aromatic hydrocarbons (PAHs) by high-performance liquid chromatography using a hybrid micellar mobile phase is described. The detection of PAHs was carried out using the fluorescence method with programmable excitation and emission wavelength. The method is applied to the analysis of several environmental samples (sea water, sediments, limpets, sea worms) and several of these compounds are quantitated at concentration below 70 ng L-1(kg-1) in the original samples.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0935-6304
    Keywords: Chiral GC ; chiral stationary phase ; cyclodextrin ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---2,3-Di-O-pentyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin has been evaluated as an enantioselective stationary phase for capillary gas chromatography. Experimental results show a good enantioselectivity towards compounds with different functional groups (haloalkanes, alcohols, esters, terpenoids, amino acid derivatives, and heterocycles). Column stability improves mixing the chiral phase with polysiloxane SE-54 (1 : 1).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1075-4261
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The study of the surface enhanced Raman spectroscopy (SERS) excitation profiles of 1,5-dimethylcytosine on metal colloids allows a more detailed determination of the behavior of the functional groups of this molecule in the adsorption process on the metal supports. Silver has shown its effectiveness and selectivity as a support for this technique from the point of view of its stability and capability to enhance the Raman signal coming from the adsorbate. The results are discussed in terms of the two well-known theories proposed up to now to explain the SERS phenomenon: electromagnetic and chemical (or charge transfer) models. © 1996 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗