  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 99-104 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; Micellear electrokinetic chromatography ; Organic modifiers ; Naphthalene sulfonates ; Surface water ; Thermostatting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The production and use of naphthalene sulfonates can easily cause pollution of surface and other types of waters. In the present study, capillary electrophoresis in combination with UV absorption detection was used to separate 21 amino- and hydroxy-substituted naphthalene sulfonates which included multiple isomeric compounds. The influence of various parameters such as pH (which turned out to be extremely important), temperature of the surrounding air flow, and the use of buffer additives (micelles, cyclodextrins, organic modifiers) was studied. Complete separation of all analytes including the isomers, was achieved in two runs with a 50 mM boric acid/borate buffer, containing either 100 mM sodium dodecylsulfonate or 15% acetonitrile. The limits of detection obtained for the individual compounds typically were 20μgI-1. River water samples spiked at this concentration level could be analysed using a simple three-step sample clean-up procedure.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0935-6304
    Schlagwort(e): On-line extraction ; Large volume introduction ; Capillary gas chromatography ; Atomic emission detection ; Solvent venting ; Pesticides ; Ground water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The on-line coupling of a liquid-liquid extraction system with capillary gas chromatography using atomic emission detection (GC-AED) has been studied. The required large volumes of about 100 μl of an iso-octane solution can be introduced into the GC-AED system by using the AED solvent vent and a solvent vapor exit in front of the capillary analytical column. Test solutions containing several pesticides were detected using the carbon, chlorine, nitrogen and sulfur channels. Analyte detectability (in concentration units) was improved significantly and low concentractions of the test compounds could be determined (1-5 ng/ml). Aqueous samples were on-line extracted and analyzed. The precision of the large-volume injection itself as well as the total extraction-GC-AED system was satisfactory (RSD of ca. 2 and 4%, respectively). As a real-life application, several ground water samples were screened.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0935-6304
    Schlagwort(e): Large-volume on-column injection ; gas chromatography ; infrared spectrometry ; microcontaminants ; solid-phase extraction ; open-split interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A large-volume on-column GC-cryotrapping-IR system was developed for injections of up to 100 μl of organic extracts. Considerable reduction of the solvent-and-water background and enhanced analyte detectability was achieved by using an open-split interface between the GC column and the IR detector and improving the leak-tightness of the system. The system was combined with solid-phase extraction to yield on-line SPE-GC-IR. With this set-up, sample volumes of only 20 ml sufficed to detect, and identify, microcontaminants in tap and surface water at the 0.1-1 μg/L level. Detection limits were on the order of 15 ng/L for tap water when using appropriate functional-group chromatograms. Or, in other words, SPE-GC-IR is a suitable technique for the screening of environmental water samples for functional groups, i.e. classes of compounds, of interest.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; interfacing ; sample treatment ; serum ; solid-phase extraction ; sulfonamides ; urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 459-464 
    ISSN: 0935-6304
    Schlagwort(e): Fast gas chromatography ; gas chromatography ; resistive heating ; organophosphorus pesticides ; PAHs ; triazines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed inside a metal tube which can be heated, and cooled, much more rapidly than any conventional GC oven. The EZ Flash assembly can generate temperature ramps up to 1200°/min and can be cooled down from 300 to 50°C in 30 s. Samples were injected via a conventional split/splitless injector and transferred to the GC column. The combination of a short column (5 m×0.25 mm i. d.), a high gas flow rate (up to 10 mL/min), and fast temperature programmes typically decreased analysis times from 30 min to about 2.5 min. Both the split and splitless injection mode could be used. With n-alkanes as test analytes, the standard deviations of the retention times with respect to the peak width were less than 15% (n = 7). First results on RSDs of peak areas of less than 3% for all but one n-alkane indicate that the technique can also be used for quantification. The combined use of a short GC column and fast temperature gradients does cause some loss of separation efficiency, but the approach is ideally suited for fast screening as illustrated for polycyclic aromatic hydrocarbons, organophosphorus pesticides, and triazine herbicides as test compounds. Total analysis times - which included injection, separation, and equilibration to initial conditions - were typically less than 3 min.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 69-79 
    ISSN: 0935-6304
    Schlagwort(e): Large volume injection ; PTV injector ; Water analysis ; River sediment ; Pesticides ; Polycyclic aromatic hydrocarbons (PAHs) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Temperature programmable (PTV) injectors with packed widebore (ca. 3.5 mm i.d.) liners are used for large volume injection in capillary gas chromatography with the aim to simplify and/or improve off-line sample pretreatment proecdures. A simple procedure for optimization of large volume PTV injection is described. The system performance, i.e. linearity and repeatability, is evaluated for polar nitrogen/phosphorus containing pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water extracts as well as for polycyclic aromatic hydrocarbons (PAHs) in river sediment (PTV-GC-MS).
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 20 (1997), S. 222-226 
    ISSN: 0935-6304
    Schlagwort(e): LC-GC ; Partially concurrent solvent evaporation ; Organochlorines ; PCBs ; Fatty matrices ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Off-line normal-phase LC has been used for the clean-up of compounds in our laboratory for several years. On-line coupling of this LC system, which typically yields 12 ml fractions, is not possible due to its large fraction volume. The maximum transfer volume in on-line LC-GC/ECD is approx. 300 μl. Therefore down-scaling of the LC system was attempted in order to reach these low fraction volumes. Miniaturization resulted in a 240 μ1 LC fraction containing the analytes of interest, which is transferred to GC/ECD via an on-column interface. Sensitivity requires that a minimum amount equivalent to 1-2 mg of sample should reach the GC detector; the selectivity is determined by the separation between the matrix and the last eluting target analyte.For the analysis of fatty samples, limitations were observed in the separation of dieldrin from triglycerides. Other organochlorine compounds, e.g. polychlorobiphenyls (PCBs), the DDT group, HCB and the HCHs can be analyzed with RSDs of 2-4 % (n = 10) at concentration levels of sub-μ/kg in milk fat using a 3 μm Hypersil silica 50 × 1.0 mm i.d. LC column.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; Continuous liquid-liquid extraction ; Environmental applications ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The applicability of a liquid-liquid extraction system which is coupled on-line with a capillary gas chromatograph was studied for environmental and ecotoxicological analyses. The optimized and automated system was used for the determination of apolar and rather non-volatile organic compounds in aqueous samples. Relevant aspects of sample introduction, phase separation and selection of extraction solvent are discussed. Three routine-tipe applications are described, viz. an improved method for the determination of hexachlorocyclohexanes in ground water and the determination of the so-called NCC-ether and ACC-ether in ecotoxicological studies. Depending on the application studied, the concentration levels varied from 0.1 to 6000 μg/I, using ECD and/or FID detection. Typical coefficients of variation obtained with the total extraction-GC procedure were 2-25%.The system was found to be rugged, it saves time compared with set-ups involving off-line liquid-liquid extraction and considerably reduces the manual work load.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 19-27 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Large volume injection ; PTV injectors ; PTV splitless injection ; PTV solvent split injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Temperature programmable injectors with liner diameters ranging from 1 to 3.5 mm are evaluated and compared for solvent split injection of large volumes in capillary gas chromatography. The liner dimensions determine whether a large sample volume can be introduced rapidly or has to be introduced in a speed controlled manner. The effect of the injection technique used on the recovery of n-alkanes is evaluated. Furthermore the influence of the liner diameter on the occurrence of thermal degradation during splitless transfer to the analytical column is studied. Guidelines are given for the selection of the PTV liner internal diameter best suited for specific applications.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 30 (1995), S. 324-332 
    ISSN: 1076-5174
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: Early in the development of electrohydrodynamic mass spectrometry (EH-MS), it was realized that ion source performance improved when the sample liquid was supplied discontinuously to the capillary emitter. Based on this realization, an ion source was designed that operates without an external sample supply system. Its essential part is a metal capillary that serves both as the liquid reservoir and the field anode and is mounted exchangeably on a pushrod. As the liquid flow is field induced, the flow rates are extremely low, in the range of 0.2 nl min-1. Thus, in spite of high analyte concentrations needed, sample consumption is only a few picomoles per mass scan. Moreover, the emission of larger droplets is avoided, which contributes to the stability of the ion signal. As the capillary emitter is mounted on a standard emitter carrier known from field desorption (FD) MS, the new ion source is compatible with conventional FD ion sources. EH mass spectra of analytes could be obtained from substances whose solubility in glycerol was〉0.5 mol l-1. The substances investigated with the new ion source include sugars, amino acids, peptides and an antibiotic. The general characteristics of the mass spectra are essentially the same as those known from other EH ion sources. Besides abundant solvent cluster ions, only cationated or protonated molecules of the analytes could be detected, frequently with one or more solvent molecules attached to the ions. Fragment ions were not observed.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien