    Applied physics 51 (1990), S. 81-85 
    ISSN: 1432-0649
    Keywords: 87 ; 42.55 Mv ; 43.35 Yb ; 61.80 Ba
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The optical attenuation coefficient for human aorta has been measured in the 440–500 nm spectral region using the transient photoacoustic (thermoelastic) response produced by an excimer-laser-pumped dye laser. It is confirmed that diseased tissue has a significantly higher attenuation than normal samples in this spectral region. The maximum difference occurs at ∼480 nm and there is a lowering of the ablation threshold fluence for diseased tissue by a factor of ∼1.5 for dye laser ablation at this wavelength.