    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 108-113 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A method is described whereby, under software control, the scan function employed to collisionally excite ions in an ion-trap mass spectrometer is regulated so as to obtain parent ion (fixed product) tandem mass spectral data. At the same time, constant neutral-loss information is also provided. Key features are the automatic ‘intelligent’ selection of parent ions from observation of the initial mass spectrum and the scanning of the applied ‘tickle’ frequency in order to locate the precise resonance points for excitation of these ions. Results for the model compounds perfluorotributylamine (‘FC43’) and n-butylbenzene are reported and complicating effects such as the unimolecular decay of the precursor ion species and charge exchange between product ions and the original sample material are discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 415-417 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The aims of the investigation were to use the method of dynamically programmed scans to study in detail some tandem mass spectrometric characteristics of the ion-trap mass spectrometer and then to use the programs to investigate the possibility of performing benchtop gas chromatography/tandem mass spectrometry experiments on the standard instrument. In particular we have examined the effect of applying a DC ramp during the ‘tickle’ period as a means of broadening the range of resonant frequencies, thereby facilitating the tuning required to effect excitation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 55-58 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 239-242 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 73-77 
    ISSN: 0935-6304
    Keywords: Capillary supercritical fluid chromatography ; Fast analysis ; Nonvolatile analytes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography (SFC) is proving to be a viable and useful separation method for thermally labile and nonvolatile materials. As with other capillary chromatographic techniques, very fast separations can be accomplished by sacrificing total efficiency and optimizing the conditions for rapid analysis. This is achieved using short, small-bore capillary columns, increased mobile phase linear velocities and very fast pressure programming rates. These principles are demonstrated for the rapid separation of selected component systems.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 19 (1990), S. 286-294 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrospray ionization (ESI) and plasma desorption (PD) mass spectra of over 20 peptides and proteins, with molecular weights (Mr) ranging between 1182 and 143000, have been directly compared. Both techniques produced molecular ions for the majority of materials studied; however, neither approach proved to be universally applicable. PD failed for a number of proteins that were successfully analyzed by ESI, including some of very high Mr. On the other hand, ESI failed for proteins that apparently could not acquire a sufficient number of positive charges to allow transmission through the quadrupole mass filter. A non-covalently bound adduct, ribonuclease S, did not survive either method intact and a simple glycoprotein, ribonuclease B, did not yield the expected molecular ion with either approach. The mass measurement accuracy of quadrupole ESI is five to tenfold better than obtained with a commercial time-of-flight PD mass spectrometer. Furthermore, ESI's superior mass resolution (with quadrupole mass spectrometers) will prove to be particularly helpful for the characterization of mixtures of closely related materials. Sensitivity was only compared qualitatively but is highly compound dependent with both techniques. In favorable cases, ESI spectra can be obtained on low femtomolar quantities of proteins while PD typically requires several hundred femtomoles to high picomoles, depending on a number of factors including Mr.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1988), S. 411-414 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Herein, we present the first example of charge state specific facile gas-phase cleavage of an aspartic acid-methionine peptide linkage. This cleavage (Asp 75-Met 76) was observed in the α-chain of human adult hemoglobin (Hb) and was probed by electrospray ionization mass spectrometry. This specific conformational and/or charge density dependent dissociation was observed primarily in the [M + 11H]11+ and [M + 12H]12+ species. A mechanism involving an intramolecular proton transfer from the protonated carboxyl side chain of Asp 75 to the neighboring Met 76 residue yielding an anhydride moiety at the C-terminal of the Asp 75 is proposed. Dramatic differences in dissociation of [M + 13H]13+ and [M + 14H]14+ species were observed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 8-11 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography, SFC ; Fused silica capillary columns ; Rapid analysis ; Carbamate pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 145-153 
    ISSN: 0935-6304
    Keywords: Capillary columns ; Supercritical fluid chromatography ; Supercritical fluid chromatography-mass spectrometry ; SFC-MS ; Thermally labile compound analysis ; Heavy molecular weight compound analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary supercritical fluid chromatography and its combination with mass spectrometry (SFC-MS) is an important analytical methodology for the analysis of thermally labile and high molecular weight compounds. The mass spectrometer provides sensitive and highly selective detection for the chromatographic effluent. The same physical-chemical properties of supercritical fluids that provide important chromatographic advantages are also important for the transport and gas phase introduction of analyte molecules into the mass spectrometer. The low mobile phase flow rates of small diameter (〈 100 μm i.d.) capillary columns allow the total chromatographic effluent to be introduced with conventional, but often slightly modified, ion source configurations for quadrupole mass spectrometers with either electron impact (EI) or chemical ionization (CI) detection. The full range of CI reagents can also be used to obtain additional selectivity and complementary structural data. The instrumentation and operating parameters for capillary SFC-MS methods are described. The applicability and usefulness of various SFC-MS analysis methods are demonstrated using a variety of samples.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability