ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthesis and living cationic polymerization of 11-[(4-cyano-4′-biphenyl)oxy]-undecanyl vinyl ether (6-11) are described. The mesomorphic phase behavior of poly(6-11) with different degrees of polymerization was compared to that of 6-11 and of 11-[(4-cyano-4′-biphenyl) oxy] undecanyl ethyl ether (8-11) which is the model compound of the monomeric structural unit of poly(6-11). 6-11 displays a monotropic SA and a monotropic nematic mesophase while 8-11 an enantiotropic SA mesophase. Poly(6-11) with low degrees of polymerization exhibits an enantiotropic SA mesophase. Poly(6-8) with high degrees of polymerization displays an enantiotropic SX (i. e., an unidentified smectic phase) and an enantiotropic SC mesophase. These results demonstrate that the transformation of the nematic mesophase of the monomer into a smectic mesophase after polymerization, occurs at the level of monomeric structural unit.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 189-190 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Tin-selective FPD ; Triphenyltin hydroxide ; TPTH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for the determination of triphenyltin hydroxide using capillary column gas chromatography with a tin-selective flame photometric detector has been developed. Triphenyltin hydroxide and its potential metabolites are converted to methyl derivatives and separated on glass capillary columns coated with OV-101. Derivatization of triphenyltin hydroxide, triphenyltin chloride, diphenyltin dichloride, phenyltin trichloride, and bis-triphenyltin oxide is nearly quantitative with a minimum of redistribution products. The selectivity of the flame photometric detector is cearly demonstrated by the comparison of chromatographic profiles obtained from using both the flame photometric and flame ionization detectors.The use of this chromatographic system in the analysis of triphenyltin hydroxide in a fortified water sample demonstrates the potential use of this system in organotin residue chemistry.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 169-169 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 378-384 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Deactivation ; Phenylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this work, an investigation of new organosilicon hydride reagents with phenyl functional groups for deactivation and surface modification of fused silica capillary columns is described. Different reagents were tested for their ability to deactivate the fused silica surface, and actual critical surface tension measurements were made using the capillary rise method. The deactivation procedure required lower optimum temperatures than conventional methods. Deactivated capillaries and coated capillary columns were prepared and tested for reproducibility, efficiency, and surface inertness towards basic and acidic compounds at the low nanogram level.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 213-217 
    ISSN: 0935-6304
    Keywords: Capillary supercritical fluid chromatography ; Injection system ; Polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sample introduction system for capillary supercritical fluid chromatography, which allows the dissolution of the sample in the supercritical mobile phase before being introduced into the column, was constructed and evaluated. Supercritical n-pentane was shown to solvate high-molecular-weight polycyclic aromatic compounds that could not be solvated using typical liquid solvents. In addition, split injection of a supercritical fluid solution was found to be more reproducible than split injections of a liquid solution. The potential of such an injection system was demonstrated, although further developments are needed in order to make the technique of practically utility.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: Capillary columns ; Gas chromatography, GC ; Stationary phases ; Liquid crystal ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Mesomorphic biphenylcarboxylate esters were coupled via flexible aliphatic hydrocarbon spacers to a polysiloxane backbone. The influence of spacer length, percent mesomorphic substitution, and crosslinking of the stationary phase on liquid-crystalline transition temperatures and on chromatographic performance was investigated. Unique selectivity and good efficiency over a wide temperature range for gum and cross-linked liquid-crystalline phases were demonstrated by the separation of various isomeric polycyclic aromatic compounds.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 741-747 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Cyanopropylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 161-167 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Thermionic detection ; Nitrated polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thermionic detector was evaluated for capillary supercritical fluid chromatography of polar nitro-containing polycyclic aromatic compounds (nitro-PAC). Three modes of detector operation were studied. The best performance was obtained using a nitro-selective mode of detection. Although linearity was confined to a narrow range for a given source current, the sensitivity was excellent; 20 pg injected for p-nitrophenol gave a signal-to-noise ratio of 3. Conventional thermionic detection also produced good sensitivity; however, serious baseline drift was observed at high operating temperatures using density programming. A third mode, flame thermionic detection, was not acceptable because of low sensitivity. A number of nitro-PAC were successfully chromatographed using density programming at 101°C. Hydroxynitropyrenes, nitropyrene quinones, and 9-hydroxy-2-nitrofluorene, which could not be eluted in capillary gas chromatography, were successfully chromatographed here. Retention of these compounds increased sequentially on 50% n-octyl-, 5% phenyl-, and 25% biphenyl polysiloxane stationary phases, respectively. Stationary phase interactions appeared to be more a function of the polar functional groups on the aromatic rings than of the hydrocarbon character of the compounds. Solute solubility in the mobile phase and volatility were additional factors contributing to the elution of these molecules. Finally, these results were used to identify a number of nitro-PAC in a polar subfraction of a diesel particulate extract.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 413-416 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Stationary phase stability ; Stationary phase viscosity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: With recent advances in column technology it is now possible to prepare highly efficient, very inert, and thermally stable capillary columns coated with nonpolar polysiloxane stationary phases. Unfortunately, the same degree of success has not been achieved for some of the more polar polysiloxane phases. A parameter that has been studied little in the past in relation to stationary phase film stability is the viscosity of the stationary phase. In this paper the efficiency and stability of coated columns are correlated to the viscosity of the phase. Due to their structure, the viscosity of the phenyl-containing polysiloxanes change rapidly with temperature and hence, thin-film coatings are not stable at elevated temperatures. By using high viscosity phenyl-containing methylphenylpolysiloxanes which were recently synthesized, efficient and stable columns have been prepared.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...