ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Fast-atom bombardment, thermal ionization and inductively coupled plasma mass spectrometry are contrasted in comparative measurements of 64Zn/67Zn isotope ratios on samples isolated in the course of a human mineral-nutrition experiment. The data are evaluated with reference to the precision normally required in enriched stable-isotope mineral-nutrition studies, and the convenience of the mass spectrometric techniques is also compared.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 12 (1985), S. 477-488 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The main ionization methods in a mass spectrometer for isotope ratio determinations of the elements are discussed in this review. These methods are thermal ionization, spark source, electron impact, inductively coupled plasma and field desorption. As concerns thermal ionization, electron impact and field desorption, a survey of the possibilities of isotope analyses in the periodic table of the elements is given. Besides kinetic studies, trace element determination by isotope dilution technique is the main application for isotope ratio measurements of the elements. The definitive method, isotope dilution mass spectrometry, is discussed as a potential tool for achieving accurate and precise trace analyses. Using field desorption mass spectrometry, one example of calcium kinetics in man and one example of thallium trace determination in an animal tissue are given. Other metal trace analyses with the isotope dilution technique are presented for biological and medical samples using positive thermal ionization mass spectrometry. Negative thermal ions are formed for the mass spectrometric analysis of non-metals and non-metal compounds in food samples, e.g. for iodine and nitrate in milk powder. Preliminary results with the isotope dilution technique are presented for a new quadrupole thermal ionization mass spectrometer which is a low-cost instrument and can be easily handled.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 12 (1961), S. 560-569 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Observations concerning primary and secondary passivationPotentiostatic and galvanostatic measurements in sulphuric acid electrolytes have been carried out on high-purity ironchrome alloys with chromium contents ranging from 5 to 70 per cent., as well as on high-purity chromium. These measurements were supplemented by the examination of passivation curves, using the galvanostatic insertion method.The passivation currents thus measured were found to differ considerably from the values known so far. The newly found values can be calculated with the aid of an approximation formula as a function of the chromium content. Apart from the “primary” passivation, it was possible, in the concentration range from about 10 to about 40 per cent. Cr, also to observe the „secondary“ passivation which is likewise governed by the current (i) / time (t) law characteristic for passivation generally: (i - i0) t = const. As this phenomenon is greatly dependent on the pH value of the electrolyte and on the presence of complex-forming substances, it is suggested that the phenomenon might be explained by the formation, due to hydrolysis of a second passivation layer.It is assumed that, in the state of “primary passivation” the alloys are covered by a very thin film comparable to that of passive chromium, and that this film is then covered by a “secondary” passivation layer of greater thickness, similar to the iron passivation layer.In the zone of primary passivation, the alloys are anodically dissolved over the whole area whilst, the zone of secondary passivation, strong pit corrosion can be observed.
    Notes: Es wurden an sehr reinen Eisen-Chrom-Legierungen mit Cr-Gehalten von 5 bis 70% sowie an reinstem Chrom potentionstatische und galvanostatische Messungen in Schwefelsäureelektrolyten durch geführt, die durch die Untersuchung von Passivierungskurven nach der galvanostatischen Einschaltmethode ergänzt wurden.Für die Passivierungsstrommengen wurden Werte gefunden, die von den bisher bekannten erheblich abweichen. Die neu ermittelten Werte lassen sich in Abhängigkeit von Cr-Gehalt der Legierungen durch eine Näherungsformel berechnen. Neben der „primären“ konnte im Konzentrationsbereich von etwa 10 bis 40% Cr auch die „sekundäre“ Passivierung beobachtet werden, für die ebenfalls das die Passivierung kennzeichnende Strom(i)-Zeit(t)-Gesetz (i-i0) = const. gilt. Wegen der starken Abhängigkeit dieses Vorganges von pH-Wert des Elektrolyten und der Anwesenheit von Komplexbildnern wird zu dessen Erklärung die hyrolysebedingte Bildung einer zweiten Passivschicht vor geschlagen.Es wird angenommen, daß die Legierungen im „primärpassiven“ Zustand mit einer sehr dünnen Schicht belegt sind, die mit derjenigen des passiven Chroms vergleichbar ist und auf der sich bei der „sekundären“ Passivierung eine dickere zweite Schicht aufbaut die einer Eisenpassivschicht ähnelt.Im primärpassiven Gebiet werden die Legierungen auf der ganzen Fläche anodisch aufgelöst, während im sekundärpassiven Bereich starke Lochfraßbildung beobachtet wird.
    Additional Material: 21 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 60 (1988), S. 841-844 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0570-0833
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...