ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 1151-1151 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 432-434 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The electron ionization mass spectra obtained, on two types of GC/MS instrument, of an impurity peak in a sample of fluorotrichloroethene (1) were those of two different compounds, viz., the epoxide of 1 and trichloroacetyl fluoride. Confirmation of the latter structure was provided by evidence from infrared spectroscopy. A study, on both instruments, of the variation of injector, source and interface temperatures has shown that the sample impurity is actually the epoxide which, at sufficiently high interface-region temperatures, can be converted to the acyl fluoride species. Ab initio molecular orbital calculations have confirmed that the acyl fluoride is more stable than the epoxide.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 436-439 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The introduction of more rigorous regulations aimed at controlling the use of sulphonated dyestuffs and dyestuff intermediates has pointed to the need for screening methods for the presence of these involatile compounds. Although much work has been caried out recently on the mass spectrometric behaviour of these compounds, it has been concerned principally with the production of molecular weight information using novel ionization methods rather than with any attempt to obtain structurally diagnostic fragment ions. In this mass spectrometric investigation of a range of naphthalene sulphonic acid salts, positive-ion and negative-ion fast-atom bombardment (FAB) mass spectra have been obtained and FAB-tandem mass spectrometry (MS/MS) has been used to acquire spectra (daugher-ion, parent-ion and neutral-loss) in an attempt to develop a useful screening method. On known compounds, best results were found when using a negative-ion neutral-loss scan to detect the loss of 64 mass units (corresponding to loss of SO2). This was confirmed by successful use of this scan to screen a sample of sulphonate residues.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 269-271 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The design and use of an RF-only collision-cell ramp generator is described. The generatio controls the collision energy voltage applied to the RF-only collision cell in a hybrid mass spectrometer of BEqQ geometry. The generator enables the collision-cell voltage to be increased or decreased in a linear ramp, over the full 500 V available. The start/stop functions of the ramp are synchronized under data system control to the scan of the quadrupole mass analyser. The collision-induced dissociation spectra so produced show an increase in the product ion abundance.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 608-615 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The results of thin layer chromatography/mass spectrometry (TLC/MS) and thin layer chromatography/tandem mass spectrometry (TLC/MS/MS) experiments are described. Spectra from the analytes were obtained directly from the absorbent without the need for extraction prior to analysis by mass spectrometry. These results illustrate the added specificity that the tandem mass spectrometer can afford in the detection and characterization of a range of compounds separated by TLC.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 28 (1993), S. 626-634 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fragmentation pathways of the synthetic pyrethroid cypermethrin and four structurally related insecticides were investigated using a tandem quadrupole mass spectrometer incorporating a hexapole collision cell under positive-ion electron impact ionization conditions. Conventional mass spectrometry using the first quadrupole analyser only and tandem mass spectrometry on selected precursor ions and product ions, and also constant neutral loss scan experiments, were used. Mechanisms and fragmentation pathways are proposed to explain the inherent stability of ions associated with the benzylphenoxy portion of this class of insecticide.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Molecular Reproduction and Development 37 (1994), S. 48-53 
    ISSN: 1040-452X
    Keywords: Cattle ; IVM ; IVC ; IVF ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: The aim of the present series of experiments was to investigate the effect of the size of follicle from which the oocytes originate on their subsequent in vitro developmental ability. Ovarian follicles were isolated and grouped according to size (2-6 mm, 〉6 mm). Primary oocytes were carefully liberated and grouped according to morphology into one of five categories: denuded; expanded; with two or three layers of cumulus; with four or five layers; and with many (six or more) layers. Following in vitro maturation (IVM), fertilization (IVF), and culture (IVC), more oocytes with many layers of cumulus (P 〈 0.01, 70.2%, 73/104 vs. 46.8%, 87/186, respectively) and a higher proportion of blastocysts were obtained from follicles 〉 6 mm compared to 2-6 mm follicles (P 〈 0.01, 65.9%, 60/91 from 〉6 mm follicles vs. 34.3%, 34/99 from 2-6 mm follicles, respectively). Use of follicular fluid (BFF) from follicles of different sizes in the IVM medium did not significantly increase the cleavage rate or blastocyst yield compared to controls. Administration of procine folliclestimulating hormone (pFSH) to donors prior to slaughter was investigated as a possible means of increasing the number of larger sized follicles in the ovaries and, thereby, the quality of the recovered oocytes. It was found that administration of six injections of pFSH beginning 3 days prior to slaughter resulted in a significant increase (P 〈 0.001) in the proportion of follicles 〉6 mm in diameter (31.6%) compared to that in nontreated controls (6.6%) and to animals that received only four injection groups (9.4%). The blastocyst yield from oocytes originating from 〉6 mm follicles, whether from unstimulated or from pFSH-treated animals, was approximately double that of oocytes from 2-6 mm follicles (P 〈 0.01; 42.9%, 24/56 for 〉6 mm follicles vs. 22.8%, 21/92 for 2-6 mm follicles, respectively, for the 6 pFSH group; P 〉 0.05; 62.5%, 5/8 for 〉6 mm follicles vs. 32.8%, 22/67 for 2-6 mm follicles, respectively, for the control). © 1994 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 829-830 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...