ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Molecular Diversity Preservation International  (13)
  • 1
    Publication Date: 2020-04-30
    Description: Most wearable intelligent biomedical sensors are battery-powered. The batteries are large and relatively heavy, adding to the volume of wearable sensors, especially when implanted. In addition, the batteries have limited capacity, requiring periodic charging, as well as a limited life, requiring potentially invasive replacement. This paper aims to design and implement a prototype energy harvesting technique based on wireless power transfer/magnetic resonator coupling (WPT/MRC) to overcome the battery power problem by supplying adequate power for a heart rate sensor. We optimized transfer power and efficiency at different distances between transmitter and receiver coils. The proposed MRC consists of three units: power, measurement, and monitoring. The power unit included transmitter and receiver coils. The measurement unit consisted of an Arduino Nano microcontroller, a heart rate sensor, and used the nRF24L01 wireless protocol. The experimental monitoring unit was supported by a laptop to monitor the heart rate measurement in real-time. Three coil topologies: spiral–spiral, spider–spider, and spiral–spider were implemented for testing. These topologies were examined to explore which would be the best for the application by providing the highest transfer power and efficiency. The spiral–spider topology achieved the highest transfer power and efficiency with 10 W at 87%, respectively over a 5 cm air gap between transmitter and receiver coils when a 200 Ω resistive load was considered. Whereas, the spider–spider topology accomplished 7 W and 93% transfer power and efficiency at the same airgap and resistive load. The proposed topologies were superior to previous studies in terms of transfer power, efficiency and distance.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2020-07-23
    Description: Hand gestures are a form of nonverbal communication that can be used in several fields such as communication between deaf-mute people, robot control, human–computer interaction (HCI), home automation and medical applications. Research papers based on hand gestures have adopted many different techniques, including those based on instrumented sensor technology and computer vision. In other words, the hand sign can be classified under many headings, such as posture and gesture, as well as dynamic and static, or a hybrid of the two. This paper focuses on a review of the literature on hand gesture techniques and introduces their merits and limitations under different circumstances. In addition, it tabulates the performance of these methods, focusing on computer vision techniques that deal with the similarity and difference points, technique of hand segmentation used, classification algorithms and drawbacks, number and types of gestures, dataset used, detection range (distance) and type of camera used. This paper is a thorough general overview of hand gesture methods with a brief discussion of some possible applications.
    Electronic ISSN: 2313-433X
    Topics: Computer Science
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-05-24
    Description: Continuous monitoring of breathing activity plays a major role in detecting and classifying a breathing abnormality. This work aims to facilitate detection of abnormal breathing syndromes, including tachypnea, bradypnea, central apnea, and irregular breathing by tracking of thorax movement resulting from respiratory rhythms based on ultrasonic radar detection. This paper proposes a non-contact, non-invasive, low cost, low power consumption, portable, and precise system for simultaneous monitoring of normal and abnormal breathing activity in real-time using an ultrasonic PING sensor and microcontroller PIC18F452. Moreover, the obtained abnormal breathing syndrome is reported to the concerned physician’s mobile telephone through a global system for mobile communication (GSM) modem to handle the case depending on the patient’s emergency condition. In addition, the power consumption of the proposed monitoring system is reduced via a duty cycle using an energy-efficient sleep/wake scheme. Experiments were conducted on 12 participants without any physical contact at different distances of 0.5, 1, 2, and 3 m and the breathing rates measured with the proposed system were then compared with those measured by a piezo respiratory belt transducer. The experimental results illustrate the feasibility of the proposed system to extract breathing rate and detect the related abnormal breathing syndromes with a high degree of agreement, strong correlation coefficient, and low error ratio. The results also showed that the total current consumption of the proposed monitoring system based on the sleep/wake scheme was 6.936 mA compared to 321.75 mA when the traditional operation was used instead. Consequently, this led to a 97.8% of power savings and extended the battery life time from 8 h to approximately 370 h. The proposed monitoring system could be used in both clinical and home settings.
    Electronic ISSN: 2224-2708
    Topics: Electrical Engineering, Measurement and Control Technology , Computer Science
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-03-29
    Description: In this paper, the performance of coded systems is considered in the presence of Suzuki fading channels, which is a combination of both short-fading and long-fading channels. The problem in manipulating a Suzuki fading model is the complicated integration involved in the evaluation of the Suzuki probability density function (PDF). In this paper, we calculated noise PDF after the zero-forcing equalizer (ZFE) at the receiver end with several approaches. In addition, we used the derived PDF to calculate the log-likelihood ratios (LLRs) for turbo-coded systems, and results were compared to Gaussian distribution-based LLRs. The results showed a 2 dB improvement in performance compared to traditional LLRs at 10 - 6 of the bit error rate (BER) with no added complexity. Simulations were obtained utilizing the Matlab program, and results showed good improvement in the performance of the turbo-coded system with the proposed LLRs compared to Gaussian-based LLRs.
    Electronic ISSN: 2079-9268
    Topics: Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-12-10
    Description: Monitoring the cardiopulmonary signal of animals is a challenge for veterinarians in conditions when contact with a conscious animal is inconvenient, difficult, damaging, distressing or dangerous to personnel or the animal subject. In this pilot study, we demonstrate a computer vision-based system and use examples of exotic, untamed species to demonstrate this means to extract the cardiopulmonary signal. Subject animals included the following species: Giant panda (Ailuropoda melanoleuca), African lions (Panthera leo), Sumatran tiger (Panthera tigris sumatrae), koala (Phascolarctos cinereus), red kangaroo (Macropus rufus), alpaca (Vicugna pacos), little blue penguin (Eudyptula minor), Sumatran orangutan (Pongo abelii) and Hamadryas baboon (Papio hamadryas). The study was done without need for restriction, fixation, contact or disruption of the daily routine of the subjects. The pilot system extracts the signal from the abdominal-thoracic region, where cardiopulmonary activity is most likely to be visible using image sequences captured by a digital camera. The results show motion on the body surface of the subjects that is characteristic of cardiopulmonary activity and is likely to be useful to estimate physiological parameters (pulse rate and breathing rate) of animals without any physical contact. The results of the study suggest that a fully controlled study against conventional physiological monitoring equipment is ethically warranted, which may lead to a novel approach to non-contact physiological monitoring and remotely sensed health assessment of animals. The method shows promise for applications in veterinary practice, conservation and game management, animal welfare and zoological and behavioral studies.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2017-02-03
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2018-03-20
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-04
    Description: For elderly persons, a fall can cause serious injuries such as a hip fracture or head injury. Here, an advanced first aid system is proposed for monitoring elderly patients with heart conditions that puts them at risk of falling and for providing first aid supplies using an unmanned aerial vehicle. A hybridized fall detection algorithm (FDB-HRT) is proposed based on a combination of acceleration and a heart rate threshold. Five volunteers were invited to evaluate the performance of the heartbeat sensor relative to a benchmark device, and the extracted data was validated using statistical analysis. In addition, the accuracy of fall detections and the recorded locations of fall incidents were validated. The proposed FDB-HRT algorithm was 99.16% and 99.2% accurate with regard to heart rate measurement and fall detection, respectively. In addition, the geolocation error of patient fall incidents based on a GPS module was evaluated by mean absolute error analysis for 17 different locations in three cities in Iraq. Mean absolute error was 1.08 × 10−5° and 2.01 × 10−5° for latitude and longitude data relative to data from the GPS Benchmark system. In addition, the results revealed that in urban areas, the UAV succeeded in all missions and arrived at the patient’s locations before the ambulance, with an average time savings of 105 s. Moreover, a time saving of 31.81% was achieved when using the UAV to transport a first aid kit to the patient compared to an ambulance. As a result, we can conclude that when compared to delivering first aid via ambulance, our design greatly reduces delivery time. The proposed advanced first aid system outperformed previous systems presented in the literature in terms of accuracy of heart rate measurement, fall detection, and information messages and UAV arrival time.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-10-21
    Description: In the aftermath of a disaster, such as earthquake, flood, or avalanche, ground search for survivors is usually hampered by unstable surfaces and difficult terrain. Drones now play an important role in these situations, allowing rescuers to locate survivors and allocate resources to saving those who can be helped. The aim of this study was to explore the utility of a drone equipped for human life detection with a novel computer vision system. The proposed system uses image sequences captured by a drone camera to remotely detect the cardiopulmonary motion caused by periodic chest movement of survivors. The results of eight human subjects and one mannequin in different poses shows that motion detection on the body surface of the survivors is likely to be useful to detect life signs without any physical contact. The results presented in this study may lead to a new approach to life detection and remote life sensing assessment of survivors.
    Electronic ISSN: 2072-4292
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2018-10-23
    Description: Falls are the main source of injury for elderly patients with epilepsy and Parkinson’s disease. Elderly people who carry battery powered health monitoring systems can move unhindered from one place to another according to their activities, thus improving their quality of life. This paper aims to detect when an elderly individual falls and to provide accurate location of the incident while the individual is moving in indoor environments such as in houses, medical health care centers, and hospitals. Fall detection is accurately determined based on a proposed sensor-based fall detection algorithm, whereas the localization of the elderly person is determined based on an artificial neural network (ANN). In addition, the power consumption of the fall detection system (FDS) is minimized based on a data-driven algorithm. Results show that an elderly fall can be detected with accuracy levels of 100% and 92.5% for line-of-sight (LOS) and non-line-of-sight (NLOS) environments, respectively. In addition, elderly indoor localization error is improved with a mean absolute error of 0.0094 and 0.0454 m for LOS and NLOS, respectively, after the application of the ANN optimization technique. Moreover, the battery life of the FDS is improved relative to conventional implementation due to reduced computational effort. The proposed FDS outperforms existing systems in terms of fall detection accuracy, localization errors, and power consumption.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...