ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2014-11-05
    Description: This paper presents the experimental results the choked flow characteristics of a subcritical refrigerant through a converging-diverging nozzle. A test nozzle with a throat diameter of 2 mm was designed and developed. The influence of operating conditions on the choked flow characteristics, i.e., the pressure profile and mass flow rate under choked flow conditions are investigated. The results indicate that the choked flow occurs in the flow of subcritical refrigerant through nozzles under the normal working conditions of air-conditioners or heat pumps. The pressure drop near the throat is about 80% of the total pressure drop through the nozzle. The critical mass flux is about 19,800 ~ 24,000 kg/(s·m2). The critical mass flow rate increases with increasing the upstream pressure and subcooling. Furthermore, the relative errors between the model predictions and the experimental results for the critical mass flux are also presented. It is found that the deviations of the predictions for homogeneous equilibrium model and Henry-Fauske model from the experimental values are −35% ~ 5% and 15% ~ 35%, respectively
    Electronic ISSN: 1099-4300
    Topics: Chemistry and Pharmacology , Physics
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2014-03-21
    Description: This paper presents a significant method and a basic idea of waste heat recovery from high temperature slags based on Time Temperature Transformation (TTT) curves. Three samples with a fixed CaO/SiO2 ratio of 1.05 and different levels of Al2O3 were designed and isothermal experiments were performed using a Single Hot Thermocouple Technique (SHTT). The TTT curves established through SHTT experiments described well the variation of slag properties during isothermal processes. In this study, we propose a multi-stage control method for waste heat recovery from high temperature slags, in which the whole temperature range from 1500 °C to 25 °C was divided into three regions, i.e., Liquid region, Crystallization region and Solid region, based on the TTT curves. Accordingly, we put forward an industrial prototype plant for the purpose of waste heat recovery and the potential of waste heat recovery was then calculated. The multi-stage control method provided not only a significant prototype, but also a basic idea to simultaneously extract high quality waste heat and obtain glassy phases on high temperature slags, which may fill the gap between slag properties and practical waste heat recovery processes.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2014-11-11
    Description: The effect of the internal heat exchanger (IHE) on the performance of the transcritical carbon dioxide refrigeration cycle with an expander is analyzed theoretically on the basis of the first and second laws of thermodynamics. The possible parameters affecting system efficiency such as heat rejection pressure, gas cooler outlet temperature, evaporating temperature, expander isentropic efficiency and IHE effectiveness are investigated. It is found that the IHE addition in the carbon dioxide refrigeration cycle with an expander increases the specific cooling capacity and compression work, and decreases the optimum heat rejection pressure and the expander output power. An IHE addition does not always improve the system performance in the refrigeration cycle with an expander. The throttle valve cycle with IHE provides a 5.6% to 17% increase in maximum COP compared to that of the basic cycle. For the ideal expander cycle with IHE, the maximum COP is approximately 12.3% to 16.1% lower than the maximum COP of the cycle without IHE. Whether the energy efficiency of the cycle by IHE can be improved depends on the isentropic efficiency level of the expander. The use of IHE is only applicable in the cases of lower expander isentropic efficiencies or higher gas cooler exit temperatures for the refrigeration cycle with an expander from the view of energy efficiency.
    Electronic ISSN: 1099-4300
    Topics: Chemistry and Pharmacology , Physics
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2015-03-13
    Description: Waste heat recovery from high temperature slags represents the latest potential way to remarkably reduce the energy consumption and CO2 emissions of the steel industry. The molten slags, in the temperature range of 1723–1923 K, carry large amounts of high quality energy. However, the heat recovery from slags faces several fundamental challenges, including their low thermal conductivity, inside crystallization, and discontinuous availability. During past decades, various chemical methods have been exploited and performed including methane reforming, coal and biomass gasification, and direct compositional modification and utilization of slags. These methods effectively meet the challenges mentioned before and help integrate the steel industry with other industrial sectors. During the heat recovery using chemical methods, slags can act as not only heat carriers but also as catalysts and reactants, which expands the field of utilization of slags. Fuel gas production using the waste heat accounts for the main R&D trend, through which the thermal heat in the slag could be transformed into high quality chemical energy in the fuel gas. Moreover, these chemical methods should be extended to an industrial scale to realize their commercial application, which is the only way by which the substantial energy in the slags could be extracted, i.e., amounting to 16 million tons of standard coal in China.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2014-08-23
    Description: The basic transcritical CO2 systems exhibit low energy efficiency due to their large throttling loss. Replacing the throttle valve with an ejector is an effective measure for recovering some of the energy lost in the expansion process. In this paper, a thermodynamic model of the ejector-expansion transcritical CO2 refrigeration cycle is developed. The effect of the suction nozzle pressure drop (SNPD) on the cycle performance is discussed. The results indicate that the SNPD has little impact on entrainment ratio. There exists an optimum SNPD which gives a maximum recovered pressure and COP under a specified condition. The value of the optimum SNPD mainly depends on the efficiencies of the motive nozzle and the suction nozzle, but it is essentially independent of evaporating temperature and gas cooler outlet temperature. Through optimizing the value of SNPD, the maximum COP of the ejector-expansion cycle can be up to 45.1% higher than that of the basic cycle. The exergy loss of the ejector-expansion cycle is reduced about 43.0% compared with the basic cycle.
    Electronic ISSN: 1099-4300
    Topics: Chemistry and Pharmacology , Physics
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2014-08-23
    Description: The impulse turbo expander (ITE) is employed to replace the throttling valve in the vapor compression refrigeration cycle to improve the system performance. An improved ITE and the corresponding cycle are presented. In the new cycle, the ITE not only acts as an expansion device with work extraction, but also serves as an economizer with vapor injection. An increase of 20% in the isentropic efficiency can be attained for the improved ITE compared with the conventional ITE owing to the reduction of the friction losses of the rotor. The performance of the novel cycle is investigated based on energy and exergy analysis. A correlation of the optimum intermediate pressure in terms of ITE efficiency is developed. The improved ITE cycle increases the exergy efficiency by 1.4%–6.1% over the conventional ITE cycle, 4.6%–8.3% over the economizer cycle and 7.2%–21.6% over the base cycle. Furthermore, the improved ITE cycle is also preferred due to its lower exergy loss.
    Electronic ISSN: 1099-4300
    Topics: Chemistry and Pharmacology , Physics
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2016-04-08
    Description: The present study firstly proposed a method of integrated utilization of sewage sludge (SS) and coal gangue (CG), two waste products, for cement clinker products with the aim of heat recovery and environment protection. The results demonstrated that the incremental amounts of SS and CG addition was favorable for the formation of tricalcium silicate (C3S) during the calcinations, but excess amount of SS addition could cause the impediment effect on C3S formation. Furthermore, it was also observed that the C3S polymorphs showed the transition from rhombohedral to monoclinic structure as SS addition was increased to 15 wt %. During the calcinations, most of trace elements could be immobilized especially Zn and cannot be easily leached out. Given the encouraging results in the present study, the co-process of sewage sludge and coal gangue in the cement kiln can be expected with a higher quality of cement products and minimum pollution to the environment.
    Electronic ISSN: 1996-1944
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2018-05-15
    Description: Energies, Vol. 11, Pages 1247: Energy Efficiency of China’s Iron and Steel Industry from the Perspective of Technology Heterogeneity Energies doi: 10.3390/en11051247 Authors: Xiaoling Wang Feng He Linfeng Zhang Lili Chen This paper investigates energy efficiency with the presence of undeniable outputs, efficiency gaps across regions, and determinants of inefficiency of the Chinese Iron and Steel (IS) industry by combining hybrid measure technology and the meta-frontier approach. Empirical results obtained from analyses based on panel data spanning 2010–2015 reveal the necessity of green transition of the IS industry. Simultaneously addressing power supply, environmental impacts, and value creation of energy is still one of the most formidable challenges facing the IS industry nowadays. Moreover, distinct spatial heterogeneity in technology exists extensively across the regions. Energy efficiency of the IS industry in the eastern region performed the best, whereas the central and western areas fell behind due to the intension of managerial failure and expansion of the technology gap. Based on the findings, general and regional-specific policy implications and suggestions are posited.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2016-12-24
    Description: Air pollution caused by atmospheric particulate and gaseous pollutants has drawn broad public concern globally. In this paper, the spatial-temporal distributions of major air pollutants in Shenzhen from March 2013 to February 2014 are discussed. In this study, ground-site monitoring data from 19 monitoring sites was used and spatial interpolation and spatial autocorrelation methods were applied to analyze both spatial and temporal characteristics of air pollutants in Shenzhen City. During the study period, the daily average concentrations of Particulate Matter (PM10 and PM2.5) ranged from 16–189 μg/m3 and 10–136 μg/m3, respectively, with 13 and 44 over-limit days, indicating that particulate matter was the primary air pollutant in Shenzhen. The highest PM occupation in the polluted air was observed in winter, indicating that fine particulate pollution was most serious in winter. Meanwhile, seasonal agglomeration patterns for six kinds of air pollutants showed that Guangming, Baoan, Nanshan, and the northern part of Longgang were the most polluted areas and PMs were their primary air pollutants. In addition, wind scale and rainfall played an important role in dissipating air pollutant in Shenzhen. The wind direction impacted the air pollution level in Shenzhen in multiple ways: the highest concentrations for all air pollutants all occurred on days with a northeast wind; the second highest ones appeared on the days with no wind. The concentrations on days with north-related winds are higher on average than those of days with south-related winds.
    Electronic ISSN: 2220-9964
    Topics: Architecture, Civil Engineering, Surveying , Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2018-01-24
    Description: IJERPH, Vol. 15, Pages 178: The Association between Air Pollution and Outpatient and Inpatient Visits in Shenzhen, China International Journal of Environmental Research and Public Health doi: 10.3390/ijerph15020178 Authors: Yachuan Liu Shanen Chen Jian Xu Xiaojian Liu Yongsheng Wu Lin Zhou Jinquan Cheng Hanwu Ma Jing Zheng Denan Lin Li Zhang Lili Chen Nowadays, air pollution is a severe environmental problem in China. To investigate the effects of ambient air pollution on health, a time series analysis of daily outpatient and inpatient visits in 2015 were conducted in Shenzhen (China). Generalized additive model was employed to analyze associations between six air pollutants (namely SO2, CO, NO2, O3, PM10, and PM2.5) and daily outpatient and inpatient visits after adjusting confounding meteorological factors, time and day of the week effects. Significant associations between air pollutants and two types of hospital visits were observed. The estimated increase in overall outpatient visits associated with each 10 µg/m3 increase in air pollutant concentration ranged from 0.48% (O3 at lag 2) to 11.48% (SO2 with 2-day moving average); for overall inpatient visits ranged from 0.73% (O3 at lag 7) to 17.13% (SO2 with 8-day moving average). Our results also suggested a heterogeneity of the health effects across different outcomes and in different populations. The findings in present study indicate that even in Shenzhen, a less polluted area in China, significant associations exist between air pollution and daily number of overall outpatient and inpatient visits.
    Print ISSN: 1661-7827
    Electronic ISSN: 1660-4601
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Published by MDPI Publishing
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...