ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 21 (1988), S. 972-974 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A novel method for the determination of strain in moving objects is presented. It is based on X-ray diffraction in parallel-beam geometry. This geometry is not affected by errors of the sample position. Thus also moving objects can be investigated. Feasibility tests were made investigating the rotor blades of a turbo pump during rotation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 25 (1992), S. 571-577 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Powder diffraction studies with synchrotron radiation were performed on a time scale down to 2.5 ms at the HASYLAB beamline B2 with a commercial 1024 pixel linear photodiode-array detector system (OMA III, EG&G–PARC). The flux rate of 2 x 108 photons s−1 at a wavelength of 1.26 Å achieved by using a toroidal mirror and a standard double-crystal Si(111) monochromator was measured with an ionization chamber at the focus. With a synthetic multilayer to select the desired wavelength instead of the standard monochromator, a flux rate of 1.5 x 1010 photons s−1 was measured at a wavelength of 1.31 Å. The shortest possible recording times for a complete powder pattern of calcium fluoride were 200 ms with the crystal monochromator and 2.5 ms with the multilayer. The angular resolution for both cases is discussed. The high-speed data collection was successfully applied with the double-crystal and multilayer monochromators to the recording of more-complex patterns and to monitor a phase transformation in order to demonstrate the feasibility of kinetic studies on the millisecond time scale.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 33 (2000), S. 953-957 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The experimental setup for the collection of synchrotron X-ray powder diffraction data from samples with high absorption (μR 〉 10) is described. It consists of a combination of a vacuum chamber with an image-plate system. A numerical absorption correction for the applied geometry has been derived and the data were corrected accordingly. Values for f ′(Er) and f ′′(Er) were refined from eight measurements on Er5Re2O12 above and below the Er LIII absorption edge. Successful refinement of the crystallographic data has verified the high quality of the collected intensities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 41 (1985), S. 81-83 
    ISSN: 1600-5740
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 47 (1991), S. 571-577 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: The resolution functions for various powder diffractometers using parallel-beam geometry are calculated. These diffractometers consist of monochromator, sample and eventually a post-specimen analyser. The theory is thus similar to that of two- or three-axis diffractometers. Special attention has to be given to the different diffraction mechanisms occurring at perfect crystals, synthetic multilayers or mosaic crystals. Resolution functions for all three types of monochromators are presented. Experiments performed at HASYLAB and other laboratories show good agreement with theory.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...