ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • International Union of Crystallography (IUCr)  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 31 (1998), S. 533-543 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: This paper describes the development of a simple laboratory-based small-angle X-ray scattering apparatus for the study of biological macromolecules in solution. The instrument is based on a two-circular-aperture collimation design combined with a conventional rotating-anode Cu Ka X-ray source, a graphite monochromator and a multiwire area detector. The geometry of the collimator, the beam-stop-to-detector distance and the thickness of the platinum foil of the defining aperture have been optimized to reduce background scattering. The effective Q range is from 0.01 to 0.33 Å−1, where Q = (4π sin θ)/λ is the magnitude of the scattering vector, 2θ is the scattering angle and λ is the wavelength of the X-rays. The length of the collimator, the pinhole sizes and the helium-flushed sample-to-detector path can be easily changed depending on the resolution and intensity requirements of an experiment. The diffraction pattern of a polycrystalline pellet of ammonium sulfate mounted about 2.5 cm in front of the beam stop and 40 cm in front of the detector is used to monitor changes in the incident-beam intensity as well as the differences in absorption of X-rays by the sample solutions and the solvents, to ensure correct background subtractions. Data collection is controlled by a computer through a parallel DMA (direct memory access) I/O module. Data collection and reduction software has been developed. The typical data collection time is about 2 h for a 5 mg ml−1 10 kDa protein dissolved in an aqueous solution. Examples of applications of this small-angle X-ray scattering instrument to studying protein size and conformation changes are presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 11 (1978), S. 479-482 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The theory of the technique currently in use for measuring distances between subunits in macromolecular aggregates by neutron small-angle scattering is outlined. It is shown that estimates for the radii of gyration of subunits within aggregates can be extracted from neutron distance data, in addition to the distances themselves. The current status of efforts to apply these methods to determine the structure of the E. coli ribosome is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...