ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 3 (1996), S. 136-144 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A high-sensitivity HARPICON camera was developed for medical X-ray imaging using a fluorescent screen. It is an avalanche-multiplication-type image pick-up tube and is 32 times more sensitive than conventional tubes. The camera also has a wider dynamic range than conventional medical-imaging cameras because a maximum output signal current of 2.3 μA is obtained and, in high-illumination-intensity regions, photocurrent is not proportional to illumination intensity. The fluorescent screen is an intensifying screen of the type used for radiographic screen-film combinations in medical examination. An X-ray image on the screen is focused on the photoconductive layer of the pick-up tube using a coupling lens with f/0.65. Experiments were performed using monochromated X-rays at the Photon Factory. An image of a spatial resolution test chart was taken in a 525 scanning-line mode of the camera. The chart pattern of 5 line-pairs mm−1 (spatial resolution of 100 μm) was observed at an X-ray input field of 50 × 50 mm. Real-time digital images of the heart of a 12 kg dog were obtained at a frame rate of 60 images s−1 after injection of a contrast medium into an artery. The images were stored in digital format at 512 × 480 pixels with 12 bits pixel−1. High-spatial-resolution and high-contrast images of coronary arteries were obtained in aortography using X-rays with energy above that of the iodine K edge; the image quality was comparable with that of conventional selective coronary angiography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 43 (1987), S. 1175-1177 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...