ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2007-11-13
    Description: The eddy covariance (EC) measurements are widely used to estimate the amount of carbon sequestrated by terrestrial biomes. The data quality and the selection of the correct EC records become an important step in the CO2 flux determination procedure. In this paper an innovative combination of existing assessment tests is used to give a relatively complete evaluation of the net ecosystem exchange measurements. For the 2005 full-leaf season at the Hesse site, the percentage of bad quality data is relatively high (59.6%) especially during night-time (68.9%). This result strengthens the importance of the data gap filling method. The filtering used does not lead to a real improvement of the accuracy of the relationship between the CO2 fluxes and the climatic factors. The soil respiration spatial heterogeneity (on a site with relatively homogenous vegetation pattern) seems to be too important to allow this improvement. However, the data rejected present some common characteristics. Their removal lead to a 10% increase in the total amount of CO2 respired and photosynthesised during the 2005 full-leaf season. Consequently the application of our combination of multiple quality tests is able improve the inter-annual analysis. The question of a systematic application on the large database like the CarboEurope and FLUXNET is legitimate.
    Print ISSN: 1810-6277
    Electronic ISSN: 1810-6285
    Topics: Biology , Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2008-05-07
    Description: Eddy covariance (EC) measurements are widely used to estimate the amount of carbon sequestrated by terrestrial biomes. The decision to exclude an EC flux from a database (bad quality records, turbulence regime not adequate, footprint problem,...) becomes an important step in the CO2 flux determination procedure. In this paper an innovative combination of existing assessment tests is used to give a relatively complete evaluation of the net ecosystem exchange measurements. For the 2005 full-leaf season at the Hesse site, the percentage of rejected half-hours is relatively high (59.7%) especially during night-time (68.9%). This result strengthens the importance of the data gap filling method. The data rejection does not lead to a real improvement of the accuracy of the relationship between the CO2 fluxes and the climatic factors especially during the nights. The spatial heterogeneity of the soil respiration (on a site with relatively homogenous vegetation pattern) seems large enough to mask an increase of the goodness of the fit of the ecosystem respiration measurements with a dependence on soil temperature and water content when the tests are used to reject EC data. However, the data rejected present some common characteristics. Their removal lead to an increase in the total amount of CO2 respired (24%) and photosynthesised (16%) during the 2005 full-leaf season. Consequently the application of our combination of multiple quality tests is able improve the inter-annual analysis. The systematic application on the large database like the CarboEurope and FLUXNET appears to be necessary.
    Print ISSN: 1726-4170
    Electronic ISSN: 1726-4189
    Topics: Biology , Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2015-10-20
    Description: Both laboratory and field experiments were carried out in order to define suitable configuration ranges for the gas sampling systems (GSS) of infrared gas analyzers (IRGA) used in eddy covariance measurements. In the laboratory, an original dynamic calibration bench was developed in order to test the frequency attenuation and pressure drop generated by filters. In the field, IRGAs equipped with different filters or different rain cups were installed and run and the real frequency response of the complete set-up was tested. The main results are that: – Filters may have a strong impact on the pressure drop in the GSS and this impact increases with flow rate. – On the contrary, no impact of the tested filters on cut off frequency was found, GSS with and without filters presenting similar cut off frequencies. – The main limiting factor of cut off frequency in the field was found to be the rain cup design. In addition, the impact of this design on pressure drop was also found noteworthy.
    Electronic ISSN: 1867-8610
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...