ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2012-06-08
    Description: From an environmental perspective, the underground metro system is one of the cleanest forms of public transportation in urban agglomerations. Current studies report contradicting results regarding air quality in the metro systems: whereas some reveal poor air quality, others report PM levels which are lower or of the same order of magnitude than those measured in traffic sites above ground level. The present work assesses summer and winter indoor air quality and passenger exposure in the Barcelona metro, focusing on PM levels and their metal contents. In addition, the impact on indoor air quality of platform screen door systems (automated systems consisting of closed rail track and platforms) is evaluated, to determine whether these systems reduce passenger exposure to PM when compared with conventional systems (open tracks and platforms). In the Barcelona metro PM levels inside the trains in summer are amongst the lowest reported for worldwide metro systems (11–32 μg m−3 PM2.5). This is most likely due to the air conditioning system working in all carriages of the Barcelona metro during the whole year. Levels were considerably higher on the platforms, reaching mean levels of 46 and 125 μg m3 in the new (L9) and old (L3) lines, respectively. PM10 data are also reported in the present study, but comparison with other metro systems is difficult due to the scarcity of data compared with PM2.5. Results showed distinct PM daily cycles, with a drastic increase from 06:00 to 07:00 a.m., a diurnal maximum from 07:00 to 10:00 p.m., and marked decrease between 10:00 p.m. and 05:00 a.m. The elements with the highest enrichment were those associated with wheel or brake abrasion products (Ba, Fe, Cu, Mn, Cr, Sb, As, Mo, Co, Sr, among others). Laminar hematite (Fe2O3) was the dominant particle type, being mainly originated by mechanical abrasion of the rail track and wheels. Regarding passenger exposure to PM, the contribution of commuting by metro was estimated to account for around 10% of the daily exposure. However, this contribution may be one order of magnitude higher when specific matals are considered. Finally, we conclude that the implementation of platform screen door systems results in reductions of both PM levels and metal concentrations. In addition an advanced optimized ventilation system gave even a much higher efficiency in reducing exposure to PM of metro commuters. Combining these two features PM exposure levels in the platforms may be reduced down by a factor of 7 with respect the old subway lines in Barcelona.
    Print ISSN: 1680-7316
    Electronic ISSN: 1680-7324
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
  • 3
    Publication Date: 2012-03-02
    Description: From an environmental perspective, the underground metro system is one of the cleanest forms of public transportation in urban agglomerations. Current studies report contradicting results regarding air quality in the metro systems: whereas some reveal poor air quality, others report PM levels which are lower or of the same order of magnitude than those measured in traffic sites above ground level. The present work assesses summer indoor air quality and passenger exposure in the Barcelona metro, focusing on PM levels and their metal contents. In addition, the impact on indoor air quality of platform screen door systems (automated systems consisting of closed rail track and platforms) is evaluated, to determine whether these systems reduce passenger exposure to PM when compared with conventional systems (open tracks and platforms). In the Barcelona metro, PM levels inside the trains in summer are amongst the lowest reported for worldwide metro systems (11–32 μPM2.5 m−3). This is most probably due to the air conditioning system working in all carriages of the Barcelona metro during the whole year. On the platforms, levels were considerably higher, reaching mean levels of 59 and 88 μgPM2.5 m−3 in the new (L9) and old (L3) lines, respectively. PM10 data are also reported in the present study, but comparison with other metro systems is more difficult due to the scarcity of data compared with PM2.5. Results showed clear PM daily cycles, with a drastic increase from 06:00 to 07:00 a.m., a diurnal maximum from 07:00 a.m. to 10:00 p.m., and marked decreases between 10:00 p.m. and 05:00 a.m. The elements with the highest enrichment are those associated with wheel or brake abrasion products (Ba, Fe, Cu, Mn, Cr, Sb, As, Mo, Co, Sr, among others). Laminar hematite (Fe2O3) was the dominant particle type, being mainly originated by mechanical abrasion of the rail track and wheels. Regarding passenger exposure to PM inside the metro system, the contribution of commuting by metro was estimated to account for around 10% of the daily exposure. Finally, we conclude that the implementation of platform screen door systems results in reductions of both PM levels and metal concentrations, but in addition an advanced optimized ventilation system gave even a much higher efficiency in reducing PM exposure to metro commuters. Combining these two features PM exposure levels in the platforms may be reduced down by a factor of 7 with respect the old subway lines in Barcelona.
    Electronic ISSN: 1680-7375
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2010-12-10
    Description: The ultraviolet (UV) index is the variable most commonly used to inform the general public about the levels and potential harmful effects of UV radiation incident at Earth's surface. This variable is derived from the output signal of the UV radiometers applying conversion factors obtained by calibration methods. This paper focused on the influence of the use of two of these methods (called one-step and two-steps methods) on the resulting experimental UV Index (UVI) as measured by a YES UVB-1 radiometer located in a midlatitude station, Granada (Spain) for the period 2006–2009. In addition, it is also analyzed the difference with the UVI values obtained when the calibration factors provided by the manufacturer are used. For this goal, the detailed characterization of the UVB-1 radiometer obtained in the first Spanish calibration campaign of broadband UV radiometers at the "El Arenosillo" INTA station in 2007 is used. In addition, modeled UVI data derived from the LibRadtran/UVSPEC radiative transfer code are compared with the experimental values recorded at Granada for cloud-free conditions. The absolute mean differences between the measured and modeled UVI data at Granada are around 5% using the one-step and two-steps calibration methods. This result indicates the excellent performance of these two techniques for obtaining UVI data from the UVB-1 radiometer. In contrast, the application of the calibration factor supplied by the manufacturer produces a high overestimation (~14%) of the UVI values. This fact generates unreliable alarming high UVI data in summer when the manufacturer's factor is used. Thus, days with an extreme erythemal risk (UVI higher than 10) increase up to 46% of all cases measured between May and September at Granada when the manufacturer's factor is applied. This percentage is reduced to a more reliable value of 3% when the conversion factors obtained with the two-steps calibration method are used. All these results report about the need of a sound calibration of the broadband UV instruments in order to obtain reliable measurements.
    Electronic ISSN: 1867-8610
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-03-10
    Description: The ultraviolet index (UVI) is the most commonly used variable to inform about the level and potential harmful effect of ultraviolet (UV) radiation reaching the Earth's surface. This variable is derived from the output signal of UV radiometers applying conversion factors from calibration methods. This paper focused on the influence of the use of two of these methods (called one-step and two-steps methods) on the experimental UVI measured by a YES UVB-1 radiometer located in a midlatitude station, Granada (Spain) for the period 2006–2009. In addition, it also analyzes the deviation from the UVI values obtained when the manufacturer's calibration factors are applied. For this goal, a detailed characterization of the UVB-1 radiometer from the first Spanish calibration campaign of broadband UV radiometers at the "El Arenosillo" INTA station in 2007 was used. In addition, modeled UVI data derived from the LibRadtran/UVSPEC radiative transfer code are compared with the experimental values recorded at Granada for cloud-free conditions. Absolute mean differences between measured and modeled UVI data at Granada were around 5% using the one-step and two-steps calibration methods, indicating an excellent performance of these two techniques for obtaining UVI data from the UVB-1 radiometer. Conversely, the application of the manufacture's calibration factor produced a large overestimation (~14%) of the UVI values, generating unreliable alarming high UVI data in summer. Thus, the number of days with an extreme erythemal risk (UVI higher than 10) increased up to 46% between May and September at Granada. This percentage reduced to a more reliable value of 3% when the conversion factors obtained with the two-steps calibration method are used. These results evidence the need for a sound calibration of the broadband UV instruments in order to obtain reliable measurements.
    Print ISSN: 1867-1381
    Electronic ISSN: 1867-8548
    Topics: Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...