    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Examination is made of the relation between the distribution function of the ions confined in a tandem mirror and the current–voltage (I–V) characteristics of the end loss ions collected on a gridded energy analyzer. To do this, a model ion distribution function characterized by two parameters, an anisotropy parameter χ and a decay parameter Y is used. The decay parameter represents depletion of ion distribution in the loss cone. A Maxwellian distribution as the limit of Y=∞ is shown not to reproduce the measured I–V curve as an energy spectrum of the ions lost from the central cell of the GAMMA 10 tandem mirror [Phys. Rev. Lett. 55, 939 (1985)]. The ions in the central cell are subject to strong ICRH and have a highly anisotropic velocity distribution. These ions are deeply trapped in the central cell and the loss cone is not fully occupied. The model distribution with a small value of Y represents such features of the ion distribution. From comparison between a measured loss current and calculated one, the decay parameter of the model distribution function is roughly determined. The model distribution with this parameter yields I–V characteristics similar to the measured one. The present article gives the relation between the apparent ion temperature Ti simply determined from the slope of the log plot of the measured I–V curve and the real parallel ion temperature Ti(parallel). When the ion distribution is of a loss cone type, Ti is almost equal to Ti(parallel). On the other hand, Ti can be more than two times as high as Ti(parallel) if the ion distribution is Maxwellian-like. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2422-2427 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: In conventional infrared (IR) thermographic cameras it is normally assumed that the ambient temperatures of optical objects are the same as the temperature determined at the camera head. In increasing cases of application of thermography, this assumption is not always satisfied, and often leads to erroneous results. In this article, we propose a determination scheme of the true temperature of such objects in an explicit form of equation to be solved by combining the readout temperature of the camera with a response function of the camera to a blackbody. The equation can be used to determine optical properties of components in an IR system. It also works to evaluate the contribution coming from each element along the optical path. Though the scheme is written in a form applicable to a specific camera among commercial products, it can be modified so that conventional IR cameras are conveniently used for thermographic determination of the temperature of gray objects in exotic environments. © 1997 American Institute of Physics.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit