ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1955-1959  (29)
  • 1930-1934  (2)
Collection
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Monatshefte für Chemie 88 (1957), S. 892-895 
    ISSN: 1434-4475
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wird die Synthese des Tetra-tert.-butoxygermans über Germaniumtetrachlorid und Natrium-tert.-butylat in tert.-Butanol als Lösungsmittel beschrieben und anderen Darstellungsmethoden gegenübergestellt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 118-122 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Since a previously used analytical procedure for small amounts of germanium (except when a radioactive isotope of germanium was employed) does not proceed quantitatively, a new method was worked out for isolating the germanium. It is based on the continuous extraction of germanium tetrabromide from 6N hydrobromic acid with ether, from which the germanium tetrabromide can then be extracted with water and determined photometrically whith phenylfluorone. This method was applied successfully to a zinc blende, whose germanium content was 0.037% (as determined by radioactive measurement). An average of 0.036% germanium was found.
    Abstract: Résumé La méthode analytique exposée antérieurement ne permet pas la détermination quantitative de petites quantités de germanium (sauf lorsqu'on emploie un isotope radioactif de ce métal). On a mis au point une méthode nouvelle pour isoler ce métal. Elle est basée sur l'extraction continue, par l'éther, du tétrabromure de germanium de l'acide bromhydrique 6 N; on extrait ensuite le tétrabromure de l'éther par l'eau et détermine le métal photométriquement par la phénylfluorone. Cette méthode a été appliquée avec succès àla blende (ZnS) contenant 0,037% de germanium (déterminé par mesure radioactive). On a trouvé un taux moyen de 0,036%.
    Notes: Zusammenfassung Da ein früher angewandter Analysengang für kleine Mengen Germanium (ausgenommen bei Verwendung eines radioaktiven Germaniumisotops) nicht quantitativ verläuft, wurde eine neue Methode zur Abtrennung des Germaniums ausgearbeitet. Sie beruht auf der kontinuierlichen Extraktion des Germaniumtetrabromids aus 6-n Bromwasserstoffsäure mit Äther, aus dem das Germaniumtetrabromid sodann mit Wasser ausgezogen und photometrisch mit Phenylfluoron bestimmt wird. Diese Methode wurde mit Erfolg auf eine Zinkblende, deren Germaniumgehalt auf Grund der radioaktiven Messung 0,037% Ge betrug, angewendet, wobei im Mittel 0,036% Ge gefunden wurden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1283-1309 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method is given for the simple, rapid, and quantitative separation of microgram quantities of uranium from those elements which, following a single ether extraction from nitric acid solution, may enter the extract along with the uranium. In contrast to the other elements concerned, the uranyl ion forms a negatively charged acetate complex in the ph range 4.25–5.25. This product is retained by the strongly basic anion exchanger Amberlite I. R. A.-400 (Ac−) and can readily be eluted again by means of 0.8N hydrochloric acid. The uranium in the eluate is finally determined by an improved form of the polarographic method announced byHarris andKolthoff involving the catalytic nitrate wave. A study was made of the characteristics of the polarographic wave of microgram amounts of uranium in nitrate-containing added electrolytes as function of nitrate, hydrogen, and salt concentrations. After removing all polyvalent cations by means of the ion exchanger Amberlite I. R. A.-400, the findings permitted a rapid and accurate determination of quantities of uranium between 0.1 and 10 μg in rocks and natural waters. On the basis of test solutions and minerals, it was found that the polarographic determination of uranium, following previous accumulation of the uranium by a single extraction with ether and subsequent ion exchange, is more accurate and particularly consumes far less time than the method previously employed which made use of the sodium fluoride bead (after preliminary accumulation of the uranium by extracting twice with ether).
    Abstract: Résumé Description d'une méthode simple, rapide et quantitative permettant la séparation de quantités d'uranium de l'ordre de grandeur du microgramme de tous autres éléments subsistant dans un unique extrait à l'éther d'une solution nitrique acide. Dans la zone de pH comprise entre 4,25 et 5,25, et contrairement aux autres ions présents, l'ion uranyle donne lieu à la formation d'un acétate complexe, chargé négativement qui est retenu par un échangeur d'anion fortement basique: l'Amberlite I. R. A.-400 (Ac−); il peut être ensuite aisément élué par l'acide chlorhydrique 0,8 N. Le dosage final de l'uranium dans l'éluat est effectué à l'aide d'une forme améliorée de la méthode polarographique deHarris etKolthoff basée sur l'étude de la vague de nitrate catalytique. L'auteur a étudié les propriétés de la vague correspondant à des quantités d'uranium de l'ordre de grandeur du microgramme, dans des solutions comportant des électrolytes d'addition à base de nitrates, en fonction de la concentration du nitrate, de l'ion hydrogène et de sels. Les résultats obtenus ont permis d'établir qu'après l'élimination de tous les cathions polyvalents à l'aide de l'échangeur d'ions Amberlite I. R. A.-400, il est possible d'effectuer un dosage rapide et précis de quantités d'uranium comprises entre 0,1 et 10μg dans les minéraux et les eaux naturelles. Des essais effectués sur des solutions et des minéraux types ont permis d'établir les conclusions suivantes. On obtient des résultats plus précis et gagne un temps considérable lorsqu'on remplace l'ancienne méthode de dosage de l'uranium à la perle de fluorure de sodium (qui comportait un enrichissement préalable par double extraction à l'éther) par la méthode polarographique (qui ne comporte qu'une extraction unique à l'éther suivie d'un traitement sur échangeur d'ion).
    Notes: Zusammenfassung Es wird eine einfache, rasche und quantitative Trennungsmethode von Mikrogrammengen Uran von jenen Elementen, die nach einmaliger Ätherextraktion aus salpetersaurer Lösung neben dem Uran im Extrakt auftreten können, angegeben. Das Uranylion bildet im pH-Bereich von 4,25 bis 5,25 zum Unterschied von den anderen in Frage kommenden Elementen einen negativ geladenen Acetatkomplex, der vom stark basischen Anionenaustauscher Amberlite I. R. A.-400 (Ac−) festgehalten wird und leicht wieder mit 0,8-n Salzsäure eluierbar ist. Zur Endbestimmung des Urans im Eluat wird die erstmalig vonHarris undKolthoff angegebene polarographische Methode der katalytischen Nitratwelle in verbesserter Form angewendet. Es wurden die Eigenschaften der polarographischen Welle von Mikrogrammengen Uran in nitrathaltigem Zusatzelektrolyten als Funktion von Nitrat-, Wasserstoffionen- und Salzkonzentration untersucht. Die daraus gewonnenen Ergebnisse gestatten nach Abtrennung aller mehrwertigen Kationen mit dem Ionenaustauscher Amberlite I. R. A.-400 eine rasche und genaue Bestimmung von Uranmengen zwischen 0,1 und 10 μg in Gesteinen und natürlichen Wässern. Dabei wurde an Testlösungen und Mineralen festgestellt, daß die polarographische Uranbestimmung nach vorhergehender Urananreicherung durch einmalige Ätherextraktion und anschließenden Ionenaustausch sich gegenüber der früher verwendeten Uranbestimmungsmethode mittels der Natriumfluoridperle (nach vorhergehender Urananreicherung durch zweimalige Ätherextraktion) durch größere Genauigkeit, aber vor allem durch geringeren Zeitaufwand auszeichnet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 1076-1085 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Two rapid and accurate methods of determining gallium with the azo dyes Solochrome red E. R. S. and Solochrome black W. E. F. A. were worked out. These methods are based on an increase in the fluorescence, proportional to the gallium concentration, after the addition of suitable amounts of the dyes in aqueous or amylalcohol solution. It is possible to determine 0.1 to 8μg gallium in 10 ml solution with an average accuracy of approximately ±5%. The gallium ion must be concentrated beforehand by extraction with ether. To remove residual foreign ions it is necessary to make a paper chromatographic separation or to use an ion exchanger. These latter points will be reported elsewhere.
    Abstract: Résumé On a mis au point deux méthodes microanalytiques rapides et précises pour le dosage de l'ion gallium avec les colorants azoïques Rouge Solochrome E. R. S. et Noir Solochrome W. D. F. A. Ces méthodes sont basées sur une croissance de la fluorescence proportionnelle à la concentration du gallium, après addition de quantités correspondantes des colorants en solution aqueuse ou dans l'alcool amylique. On peut ainsi doser 0,1 à 8μg de gallium en 10 ml de solution avec une précision moyenne d'environ ±5%. Les ions gallium doivent subir une concentration préalable à l'aide d'une extraction à l'éther. Il est nécessaire d'éliminer les ions étrangers restants qui perturberaient le dosage soit par séparation chromatographique sur papier, soit par emploi d'un échangeur d'ions; ces traitements feront l'objet d'une autre publication.
    Notes: Zusammenfassung Es wurden zwei rasch ausführbare und genaue mikroanalytische Bestimmungsmethoden des Galliumions mit den Azofarbstoffen Solochrom-Rot E. R. S. und Solochrom-Schwarz W. D. F. A. ausgearbeitet. Diese Methoden beruhen auf einer der Galliumkonzentration proportionalen Zunahme der Fluoreszenz nach Zugabe entsprechender Mengen der Farbstoffe in wäßriger bzw. amylalkoholischer Lösung. Es sind 0,1 bis 8μg Ga in 10 ml Lösung mit einer durchschnittlichen Genauigkeit von etwa ±5% bestimmbar. Das Galliumion muß vorher durch Ätherextraktion angereichert werden. Zur Entfernung verbliebener Spuren störender Fremdionen ist eine Trennung auf papierchromatographischem Wege oder mittels eines Ionenaustauschers erforderlich, worüber an anderer Stelle berichtet werden wird.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 1100-1102 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 45 (1957), S. 485-495 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The method described here for collecting uranium (VI) is analogous to the familiar ether extraction4. In a nitric acid solution, saturated with ammonium nitrate, the uranyl ion forms a negatively charged uranyl nitrate complex, which is retained quantitatively by the strong basic anion exchanger Amberlite I. B, A.-400 (NO3 −). All ions, which can interfere with the operation of the column, including also phosphate ion, are, however, separated off under the prescribed conditions. After the column is washed with half-saturated ammonium nitrate solution, the uranium is eluted with nitric acid (1 + 9). The uranium in the eluate is determined quantitatively by a polarographic procedure employing the catalytic nitrate wave3. The method yields results that are just as good as the other procedures used heretofore.
    Abstract: Résumé La nouvelle méthode qui est décrite pour l'enrichissement en uranium (VI) est analogue à l'extraction par l'éther bien connue4. Dans une solution d'acide nitrique presque saturée en nitrate d'ammonium, l'ion uranyle donne naissance à un complexe nitrate-uranyle chargé négativement qui est retenu quantitativement par l'échangeur d'anions fortement basique, la résine Amberlite I. R. A.-400 (NO3 −). Tous les ions qui étaient susceptibles de perturber l'opération sur colonne, y compris l'ion phosphate, sont au contraire séparés dans les conditions choisies pour l'essai. Après lavage de la colonne avec une solution de nitrate d'ammonium demi-saturée, l'uranium est élué avec de l'acide nitrique (1 + 9). L'uranium est alors dosé polarographiquement dans l'éluat, grâce à la vague catalytique du nitrate3. Cette technique permet d'obtenir d'aussi bons résultats que ceux qui sont fournis par les méthodes habituellement employées jusqu'à ce jour.
    Notes: Zusammenfassung Die beschriebene neue Anreicherungsmethode des Uran(VI) ist der bekannten Ätherextraktion4 analog. Das Uranylion bildet in einer salpetersauren und mit Ammoniumnitrat fast-gesättigten Lösung einen negativ geladenen Uranylnitratokomplex, der quantitativ vom stark basischen Anionenaustauscher Amberlite I.R.A.-400 (NO3 −) festgehalten wird. Alle Ionen, die die Säulenoperation stören könnten, darunter auch Phosphation, werden dagegen unter den gewählten Versuchsbedingungen abgetrennt. Nach dem Waschen der Säule mit halbgesättigter Ammoniumnitratlösung wird das Uran mit Salpetersäure (1 + 9) eluiert. Im Eluat wird dann Uran auf polarographischem Wege unter Verwendung der katalytischen Nitratwelle3 quantitativ bestimmt. Bei diesem Verfahren werden ebenso gute Ergebnisse wie nach anderen bisher üblichen Methoden erzielt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple, rapid and quantitative ion exchange method has been developed which permits the separation of microgram- as well as milligram quantities of uranium as a negatively charged ascorbate complex from a large number of cations and anions by means of the highly basic anion exchanger Amberlite I. R. A.-400 (ascorbate). This method is applicable following ether extraction or it may be applied directly, whereby because of the extremely high capacity of the ion exchanger used for the uranyl ascorbate complex, it is possible to determine uranium in materials, whose uranium content is 0.0001 to 0.1% or higher.
    Abstract: Résumé Mise au point d'une méthode par échange d'ions simple, rapide et quantitative pour la séparation de l'uranium, sous forme de complexe ascorbique chargé négativement, à l'échelle du microgramme ou encore du milligramme, d'un grand nombre de cations et d'anions à l'aide de l'échangeur d'anions fortement basique: l'Amberlite I. R. A.-400 (Ascorbate). Cette méthode est applicable, soit après extraction préalable de l'uranium, soit encore directement; la capacité extraordinairement élevée de l'échangeur d'ions employé pour le complexe d'ascorbate d'uranyle rend possible la détermination de l'uranium dans des substances dont la teneur en cet élément varie entre 0,0001 et 0,1% ou plus.
    Notes: Zusammenfassung Es wurde eine einfache, rasche und quantitative Ionenaustauschmethode entwickelt, mittels deren sowohl Mikrogramm-wie auch Milligrammengen Uran als negativ geladener Ascorbinatkomplex von einer großen Anzahl von Kationen und Anionen mittels des stark basischen Anionenaustauschers Amberlite I. R. A.-400 (Ascorbinat) getrennt werden können. Diese Methode ist nach vorangehender Ätherextraktion des Urans oder auch direkt anwendbar, wobei es infolge der äußerst hohen Kapazität des verwendeten Ionenaustauschers für den Uranylascorbinatkomplex möglich ist, Uran in Materialien zu bestimmen, die Urangehalte von 0,0001 bis 0,1% oder mehr aufweisen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 896-902 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A rapid and simple method has been worked out for the microanalytical determination of uranyl ion with morin. The method is based on a quenching, proportional to the UO2 +2 ion concentration, of the fluorescence of morin in neutral solution containing acetone. An accuracy of ± 5% can be obtained within the range 0.5 to 10μg uranium in 10 ml. The uranyl ion must be separated from interfering ions by extraction with ether.
    Abstract: Résumé On a élaboré une méthode microanalytique rapide et simple pour la détermination des ions uranyle avec le Morin. La méthode repose sur l'extinction de fluorescence du Morin, en solution neutre et acétonique, proportionnelle à la concentration des ions UO2 +2. On peut estimer de 0,5 à 10μg d'uranium dans 10ml avec une précision de ± 5%. Les ions uranyles sont séparés des ions étrangers génants par extraction à l'éther.
    Notes: Zusammenfassung Es wurde eine rasche und einfache mikroanalytische Bestimmung des Uranylions mit Morin ausgearbeitet. Die Méthode beruht auf einer der UO2 ++-Ionenkonzentration proportionalen Abnahme („Löschung“) der Fluoreszenz von Morin in neutraler acetonhaltiger Lösung. Es sind 0,5 bis 10μg Uran in 10ml Lösung mit einer Genauigkeit von ± 5% bestimmbar. Das UO2 ++-Ion muß vorher durch Ätherextraktion von störenden Fremdionen abgetrennt werden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1230-1237 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new method was developed for a simple quantitative separation of microgram quantities of gallium from amounts of iron a thousand times as great. The method is based on ion exchange chromatography on strongly basic anion exchanger Amberlite I. R. A.-400. The basis of the method is the divergent stability and migration velocity of the thiocyanate complexes of these elements when eluted with 0.1 N hydrochloric acid. The gallium precedes the iron in the eluate.
    Abstract: Résumé Mise au point d'une séparation simple et quantitative de masses de gallium de l'ordre de grandeur du microgramme de masses de fer pouvant être mille fois plus élevées, par chromatographie par échange d'ions. On emploie à cette fin un échangeur d'anions fortement basique: l'amberlite I. R. A.-400. Le principe de la méthode repose sur les différences de stabilité et de vitesse de migration des suifocyanures complexes de ces éléments lors de leur élution par l'acide chlorhydrique 0, l N: le gallium passe en effet dans l'éluat avant le fer.
    Notes: Zusammenfassung Es wurde eine einfache, quantitative Trennung von Mikrogrammmengen Gallium von der bis zum Tausendfachen betragenden Menge Eisen durch Ionenaustausch-Chromatographie am stark basischen Anionenaustauscher Amberlite I. R. A.-400 ausgearbeitet. Die Methode beruht auf der unterschiedlichen Stabilität und Wanderungsgeschwindigkeit der Bhodanidkomplexe dieser Elemente bei ihrer Elution mit 0,1-n Salzsäure, wobei das Gallium vor dem Eisen ins Eluat übergeht.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1422-1430 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Two methods have been developed for the rapid determination of uranium in sea- and river waters. By this procedure, the uranyl ion can be directly determined polarographically after a single column operation and without any preliminary evaporation of the samples and without any extraction of the samples. In the case of sea waters, the gathering of the uranium is in the form of negatively charged chloride-, with river waters as negative uranyl acetate complex, which are retained quantitatively in the pH ranges 3 to 9 or 4.25 to 5.25 respectively by the strongly basic anion exchange resin Amberlite I. R. A.-400 (Cl− or Ac−). After washing the resin with a buffer solution of pH = 5.0 (HCl + NaAc) and with distilled water, the uranium can be eluted with 0.8N hydrochloric acid and determined polarographically. The uranium content of a 1 liter sample of water can be determined within 8 hours with a mean accuracy of ± 10 to 15%.
    Abstract: Résumé Mise au point de deux méthodes de détermination rapide de l'uranium dans les eaux de mer et de rivière. Ces techniques permettent de doser l'ion uranyle par polarographie immédiatement après avoir effectué un unique passage sur colonne, sans concentration préalable par évaporation et en évitant toute extraction. L'enrichissement en uranium est effectué sous forme de chlorure chargé négativement pour l'eau de mer et d'acétate d'uranyle complexe chargé négativement pour l'eau de rivière; ces composés sont en effet retenus quantitativement sur un échangeur d'anion fortement basique, l'Amberlite I. R. A. 400 (Cl− ou CH3CO2 −), dans un domaine de pH de 3 à 9 dans le premier cas et de 4,25 à 5,25 dans le second. Après lavage de la résine avec une solution tampon de pH = 5,0 (acide chlorhydrique — acétate de sodium) puis avec de l'eau distillée, l'uranium est élué avec de l'acide chlorhydrique 0,8 N et dosé par polarographie. On peut ainsi déterminer en moins de 8 heures la teneur en uranium d'un échantillon d'eau de 1 litre avec une précision moyenne de ± 10 à 15%.
    Notes: Zusammenfassung Es wurden zwei Methoden zur Schnellbestimmung des Urans in Meer- und FlußwÄssern ausgearbeitet. Nach diesen Verfahren kann das Uranylion ohne vorangehendes Eindampfen der Proben und unter Umgehung jeglicher Extraktion unmittelbar nach Durchführung einer einzigen SÄulenoperation polarographisch bestimmt werden. Bei MeerwÄssern erfolgt die Anreicherung des Urans als negativ geladener Chlorid-, bei FlußwÄssern als negativer Uranylacetatkomplex, die vom stark basischen Anionenaustauscher Amberlite I. R. A.-400 (Cl− bzw. Ac−) quantitativ in den PH-Bereichen 3 bis 9 bzw. 4,25 bis 5,25 festgehalten werden. Nach dem Waschen des Harzes mit einer Pufferlösung vom pH = 5,0 (SalzsÄure-Natriumacetat) und mit dest. Wasser lÄßt sich das Uran mit 0,8-n SalzsÄure eluieren und polarographisch bestimmen. Innerhalb von 8 Stunden kann so der Urangehalt einer Wasserprobe von 11 bei einer mittleren Genauigkeit von ± 10 bis 15% ermittelt werden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...