ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1970-1974  (14)
  • 1955-1959  (29)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Monatshefte für Chemie 102 (1971), S. 1351-1359 
    ISSN: 1434-4475
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das Verteilungsverhalten von237Np−239Np zwischen salpetersauren Lösungen verschiedener Konzentration und einem Anionenaustauscher (Dowex 1X8) wurde untersucht. Durch Reduktion mit Fe2++Hydrazin konnte quantitativ das Np(IV) hergestellt und dessen Verteilungskoeffizient (D) in 1n-10n-HNO3 bestimmt werden. Mit Hydrazin allein und bei Lösungen ohne Reduktionsmittel wurden stark schwankendeD-Werte gefunden, die auf unterschiedliche Prozentsätze an Np(IV), Np(V) und Np(VI) zurückzuführen waren. Durch die Bestimmung der Anteile der einzelnen Oxidationsstufen konnten jedoch die jeweiligenD-Werte [D(IV),D(V),D(VI)] berechnet werden. Die mit dieser Methode erhaltenen Werte stimmten gut mit den Daten überein, die an Systemen gewonnen wurden, in denen jeweils nur eine Neptuniumoxidations-stufe vorlag.
    Notes: Abstract The distribution of237Np−239Np between nitric acid solutions of different concentration and an anion exchanger (Dowex 1X8) was investigated. By reduction with Fe2++hydrazine, the Np(IV) was obtained quantitatively and its distribution coefficients (D) in 1n to 10n-HNO3 were determined. With hydrazine alone and without any reduction media, strongly varyingD-values were found. This was due to different amounts of Np(IV), Np(V), and Np(VI) in the solutions. By determining the fractions of the individual oxidation states the correspondingD-values [D(IV),D(V), andD(VI)] could be calculated. The data obtained by this method agreed well with theD-values resulting from determinations of systems, in which the individual Np-oxidation state was the only component of the corresponding solution.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Monatshefte für Chemie 88 (1957), S. 892-895 
    ISSN: 1434-4475
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wird die Synthese des Tetra-tert.-butoxygermans über Germaniumtetrachlorid und Natrium-tert.-butylat in tert.-Butanol als Lösungsmittel beschrieben und anderen Darstellungsmethoden gegenübergestellt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 59 (1971), S. 225-240 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The distribution of trace elements over four main phases of iron meteorites (metallic-, phosphidic-, graphitic- sulfidic phases) was investigated by means of neutron activation. A strong chalcophilic behavior for selenium and chromium was deduced from the distribution circumstances, as opposed to strong siderophilic behavior for the elements antimony and arsenic. Most surprisingly, the main part of the molybdenum is present in the form of schreibersite. With the exception of the elements chromium and molybdenum, all of the other elements studied by the writers are represented in those phases that also occur in chondrites Hence certain consequences with regard to the affinity changes of these elements during the creation and genesis of the meteoritic material are disclosed by the comprehensive analyses conducted for the first time by the authors.
    Notes: Zusammenfassung Die Verteilung von Spurenelementen über die vier Hauptphasen von Eisenmeteoriten (Metall-, Phosphid-, Graphit- und Sulfidphase) wurde mittels Neutronenaktivierung untersucht. Aus den Verteilungsverhältnissen ergibt sich ein stark chalkophiles Verhalten für Se und Cr, hingegen stark siderophiles Verhalten für die Elemente Sb und As. Überraschenderweise ist der Hauptteil des Mo im Schreibersit vertreten. Mit Ausnahme der Elemente Cr und Mo sind im übrigen alle von uns untersuchten Elemente in jenen Phasen vertreten, die auch in Chondriten auftreten. Aus den von uns erstmals durchgeführten umfassenden Analysen ergeben sich somit gewisse Konsequenzen für die Affinitätsänderungen dieser Elemente während der Entstehung und Genesis des meteoritischen Materials.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 59 (1971), S. 794-799 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The content of copper, arsenic, antimony and lanthanum was quantitatively determined in the standardized alloys NBS-1138 (CaS + Steel 1) and NBS-1140 (Ductile Iron 1), and in fact without destruction and likewise after a rapid group separation by means of a rapid extraction Chromatographic method in the system tri-n-octylamine-hydrochloric acid. Certificated values for copper were available in the case of both alloys, but such values were available for arsenic only in one alloy. Our analytical values showed good agreement with the certificated values if the uncertainties are taken into account. In addition, i. e. with no certificated values, we quantitatively determined antimony and lanthanum in both samples, arsenic in one sample.
    Notes: Zusammenfassung Der Gehalt an Kupfer, Arsen, Antimon und Lanthan wurde in den standardisierten Legierungen NBS-1138 (Cast Steel 1) und NBS-1140 (Ductile Iron 1) quantitativ bestimmt, und zwar sowohl zerstörungsfrei als auch nach einer schnellen Gruppentrennung auf extraktionschromatographischem Wege im System Tri-n-octylamin — Salzsäure. Für Kupfer lagen Zertifikatswerte für beide Legierungen vor, für Arsen nur für eine Legierung. Unter Berücksichtigung der angegebenen Unsicherheitsgrenzen zeigten unsere Analysenwerte gute Übereinstimmung mit den Zertifikaten. Zusätzlich, das heißt ohne Zertifikats werte, wurden von uns quantitativ Antimon und Lanthan in beiden Proben, Arsen in einer Probe bestimmt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The optimal working conditions in the elution of Zn-65 with HCl were determined for an extraction chromatographic column made of polytrifluoroethylene (Voltalef) and charged with tributyl phosphate. The columnar behavior was studied in dependance of the carrier material, charging of the column with TBP, flow velocity, temperature, distribution coefficient and charging of the column with the metal salt through the determination of the “effective height of a theoretical floor level” (H). Voltalef 300 Pl and Voltalef 300 UF proved themselves to be excellent carrier materials for the extraction chromatography with TBP as stationary phase. Under optimal elution conditions a value of 0.15 mm was found for the floor level.
    Notes: Zusammenfassung Für eine mit Tributylphosphat (TBP) beladene extraktionschromatographische Kolonne von Polytrifluormonochloräthylen (Voltalef) als Träger wurden die optimalen Arbeitsbedingungen bei der Elution von Zn-65 mit HCl bestimmt. Das Kolonnenverhalten wurde in Abhängigkeit von Trägermaterial, Beladung mit TBP, Fließgeschwindigkeit, Temperatur, Verteilungskoeffizient und Belastung der Säule mit dem Metallsalz durch die Bestimmung der „effektiven Höhe eines theoretischen Bodens“ (H) untersucht. Voltalef 300 PL und Voltalef 300 UF erwiesen sich als ausgezeichnete Trägermaterialien für die Extraktionschromatographie mit TBP als stationäre Phase. Unter optimalen Elutionsbedingungen ergab sich für die Bodenhöhe H ein Wert von 0,15 mm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Monatshefte für Chemie 101 (1970), S. 1648-1657 
    ISSN: 1434-4475
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Abstract The distribution coefficients (D) of Neptunium in the valence states (IV), (V) and (VI) between nitric acid solutions and an anion exchanger were determined. The distribution coefficientD(IV) for Np(IV) was determined after reduction of a series of samples,D(V) being taken from literature, andD(VI) was assumed to be equal toD(V) for reasons of analogy. The ratios of the valence states in the respective solutions were determined quantitatively. From this data, theD-values could also be ascertained by calculations. It was found that reduction takes place in the exchanger resin, which displaces the equilibrium towards Np(IV), andD is only determined by the protion of Np(IV). In solutions free of oxidizers,D is an additive value of all valence states and their respective concentrations.
    Notes: Zusammenfassung Die Verteilungskoeffizienten (D) von Neptunium zwischen salpetersauren Lösungen, in denen dieses Transuranelement in (IV)-, (V)- und (VI)-wertigen Oxydationsstufen vorlag, und einem Anionenaustauscher wurden gemessen. Die VerteilungskoeffizientenD(IV) für das Np(IV) wurden nach Reduktion einer Probenreihe bestimmt, währendD(V) aus der Literatur bekannt war undD(VI) aus Analogiegründen gleichD(V) gesetzt wurde. Die Anteile der einzelnen Oxydationsstufen in der jeweiligen Lösung wurden quantitativ bestimmt. Aus diesen Daten ließen sich nun dieD-Werte auch rechnerisch ermitteln. Dabei stellte sich heraus, da\ in Systemen mit Oxydationsmitteln (Cr2O7 2- und Ce4+) im Austauscherharz nach kurzer Zeit eine Reduktion eintritt, die das Gleichgewicht nach Np(IV) verschiebt, und daßD dann nur durch den Anteil an Np(IV) bestimmt wird. In nichtoxydierenden Lösungen tragen alle Oxydationsstufen entsprechend ihrer Konzentration additiv zur Größe desD-Wertes bei.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 118-122 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Since a previously used analytical procedure for small amounts of germanium (except when a radioactive isotope of germanium was employed) does not proceed quantitatively, a new method was worked out for isolating the germanium. It is based on the continuous extraction of germanium tetrabromide from 6N hydrobromic acid with ether, from which the germanium tetrabromide can then be extracted with water and determined photometrically whith phenylfluorone. This method was applied successfully to a zinc blende, whose germanium content was 0.037% (as determined by radioactive measurement). An average of 0.036% germanium was found.
    Abstract: Résumé La méthode analytique exposée antérieurement ne permet pas la détermination quantitative de petites quantités de germanium (sauf lorsqu'on emploie un isotope radioactif de ce métal). On a mis au point une méthode nouvelle pour isoler ce métal. Elle est basée sur l'extraction continue, par l'éther, du tétrabromure de germanium de l'acide bromhydrique 6 N; on extrait ensuite le tétrabromure de l'éther par l'eau et détermine le métal photométriquement par la phénylfluorone. Cette méthode a été appliquée avec succès àla blende (ZnS) contenant 0,037% de germanium (déterminé par mesure radioactive). On a trouvé un taux moyen de 0,036%.
    Notes: Zusammenfassung Da ein früher angewandter Analysengang für kleine Mengen Germanium (ausgenommen bei Verwendung eines radioaktiven Germaniumisotops) nicht quantitativ verläuft, wurde eine neue Methode zur Abtrennung des Germaniums ausgearbeitet. Sie beruht auf der kontinuierlichen Extraktion des Germaniumtetrabromids aus 6-n Bromwasserstoffsäure mit Äther, aus dem das Germaniumtetrabromid sodann mit Wasser ausgezogen und photometrisch mit Phenylfluoron bestimmt wird. Diese Methode wurde mit Erfolg auf eine Zinkblende, deren Germaniumgehalt auf Grund der radioaktiven Messung 0,037% Ge betrug, angewendet, wobei im Mittel 0,036% Ge gefunden wurden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 1283-1309 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method is given for the simple, rapid, and quantitative separation of microgram quantities of uranium from those elements which, following a single ether extraction from nitric acid solution, may enter the extract along with the uranium. In contrast to the other elements concerned, the uranyl ion forms a negatively charged acetate complex in the ph range 4.25–5.25. This product is retained by the strongly basic anion exchanger Amberlite I. R. A.-400 (Ac−) and can readily be eluted again by means of 0.8N hydrochloric acid. The uranium in the eluate is finally determined by an improved form of the polarographic method announced byHarris andKolthoff involving the catalytic nitrate wave. A study was made of the characteristics of the polarographic wave of microgram amounts of uranium in nitrate-containing added electrolytes as function of nitrate, hydrogen, and salt concentrations. After removing all polyvalent cations by means of the ion exchanger Amberlite I. R. A.-400, the findings permitted a rapid and accurate determination of quantities of uranium between 0.1 and 10 μg in rocks and natural waters. On the basis of test solutions and minerals, it was found that the polarographic determination of uranium, following previous accumulation of the uranium by a single extraction with ether and subsequent ion exchange, is more accurate and particularly consumes far less time than the method previously employed which made use of the sodium fluoride bead (after preliminary accumulation of the uranium by extracting twice with ether).
    Abstract: Résumé Description d'une méthode simple, rapide et quantitative permettant la séparation de quantités d'uranium de l'ordre de grandeur du microgramme de tous autres éléments subsistant dans un unique extrait à l'éther d'une solution nitrique acide. Dans la zone de pH comprise entre 4,25 et 5,25, et contrairement aux autres ions présents, l'ion uranyle donne lieu à la formation d'un acétate complexe, chargé négativement qui est retenu par un échangeur d'anion fortement basique: l'Amberlite I. R. A.-400 (Ac−); il peut être ensuite aisément élué par l'acide chlorhydrique 0,8 N. Le dosage final de l'uranium dans l'éluat est effectué à l'aide d'une forme améliorée de la méthode polarographique deHarris etKolthoff basée sur l'étude de la vague de nitrate catalytique. L'auteur a étudié les propriétés de la vague correspondant à des quantités d'uranium de l'ordre de grandeur du microgramme, dans des solutions comportant des électrolytes d'addition à base de nitrates, en fonction de la concentration du nitrate, de l'ion hydrogène et de sels. Les résultats obtenus ont permis d'établir qu'après l'élimination de tous les cathions polyvalents à l'aide de l'échangeur d'ions Amberlite I. R. A.-400, il est possible d'effectuer un dosage rapide et précis de quantités d'uranium comprises entre 0,1 et 10μg dans les minéraux et les eaux naturelles. Des essais effectués sur des solutions et des minéraux types ont permis d'établir les conclusions suivantes. On obtient des résultats plus précis et gagne un temps considérable lorsqu'on remplace l'ancienne méthode de dosage de l'uranium à la perle de fluorure de sodium (qui comportait un enrichissement préalable par double extraction à l'éther) par la méthode polarographique (qui ne comporte qu'une extraction unique à l'éther suivie d'un traitement sur échangeur d'ion).
    Notes: Zusammenfassung Es wird eine einfache, rasche und quantitative Trennungsmethode von Mikrogrammengen Uran von jenen Elementen, die nach einmaliger Ätherextraktion aus salpetersaurer Lösung neben dem Uran im Extrakt auftreten können, angegeben. Das Uranylion bildet im pH-Bereich von 4,25 bis 5,25 zum Unterschied von den anderen in Frage kommenden Elementen einen negativ geladenen Acetatkomplex, der vom stark basischen Anionenaustauscher Amberlite I. R. A.-400 (Ac−) festgehalten wird und leicht wieder mit 0,8-n Salzsäure eluierbar ist. Zur Endbestimmung des Urans im Eluat wird die erstmalig vonHarris undKolthoff angegebene polarographische Methode der katalytischen Nitratwelle in verbesserter Form angewendet. Es wurden die Eigenschaften der polarographischen Welle von Mikrogrammengen Uran in nitrathaltigem Zusatzelektrolyten als Funktion von Nitrat-, Wasserstoffionen- und Salzkonzentration untersucht. Die daraus gewonnenen Ergebnisse gestatten nach Abtrennung aller mehrwertigen Kationen mit dem Ionenaustauscher Amberlite I. R. A.-400 eine rasche und genaue Bestimmung von Uranmengen zwischen 0,1 und 10 μg in Gesteinen und natürlichen Wässern. Dabei wurde an Testlösungen und Mineralen festgestellt, daß die polarographische Uranbestimmung nach vorhergehender Urananreicherung durch einmalige Ätherextraktion und anschließenden Ionenaustausch sich gegenüber der früher verwendeten Uranbestimmungsmethode mittels der Natriumfluoridperle (nach vorhergehender Urananreicherung durch zweimalige Ätherextraktion) durch größere Genauigkeit, aber vor allem durch geringeren Zeitaufwand auszeichnet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 1076-1085 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Two rapid and accurate methods of determining gallium with the azo dyes Solochrome red E. R. S. and Solochrome black W. E. F. A. were worked out. These methods are based on an increase in the fluorescence, proportional to the gallium concentration, after the addition of suitable amounts of the dyes in aqueous or amylalcohol solution. It is possible to determine 0.1 to 8μg gallium in 10 ml solution with an average accuracy of approximately ±5%. The gallium ion must be concentrated beforehand by extraction with ether. To remove residual foreign ions it is necessary to make a paper chromatographic separation or to use an ion exchanger. These latter points will be reported elsewhere.
    Abstract: Résumé On a mis au point deux méthodes microanalytiques rapides et précises pour le dosage de l'ion gallium avec les colorants azoïques Rouge Solochrome E. R. S. et Noir Solochrome W. D. F. A. Ces méthodes sont basées sur une croissance de la fluorescence proportionnelle à la concentration du gallium, après addition de quantités correspondantes des colorants en solution aqueuse ou dans l'alcool amylique. On peut ainsi doser 0,1 à 8μg de gallium en 10 ml de solution avec une précision moyenne d'environ ±5%. Les ions gallium doivent subir une concentration préalable à l'aide d'une extraction à l'éther. Il est nécessaire d'éliminer les ions étrangers restants qui perturberaient le dosage soit par séparation chromatographique sur papier, soit par emploi d'un échangeur d'ions; ces traitements feront l'objet d'une autre publication.
    Notes: Zusammenfassung Es wurden zwei rasch ausführbare und genaue mikroanalytische Bestimmungsmethoden des Galliumions mit den Azofarbstoffen Solochrom-Rot E. R. S. und Solochrom-Schwarz W. D. F. A. ausgearbeitet. Diese Methoden beruhen auf einer der Galliumkonzentration proportionalen Zunahme der Fluoreszenz nach Zugabe entsprechender Mengen der Farbstoffe in wäßriger bzw. amylalkoholischer Lösung. Es sind 0,1 bis 8μg Ga in 10 ml Lösung mit einer durchschnittlichen Genauigkeit von etwa ±5% bestimmbar. Das Galliumion muß vorher durch Ätherextraktion angereichert werden. Zur Entfernung verbliebener Spuren störender Fremdionen ist eine Trennung auf papierchromatographischem Wege oder mittels eines Ionenaustauschers erforderlich, worüber an anderer Stelle berichtet werden wird.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 1100-1102 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...