Contents The pulse top shapeH z (t) of a trapezoidal magnetic field pulseH H(t) with about 3 ms duration and a maximum amplitude ofH Ho=35.8·106 A/m (450 kOe) is measured by pick-up coil and integrator as follows: The voltageu 1(t) induced in the pick-up coil is integrated only within the duration of the pulse top. It is suppressed during the pulse edges. At that timeu 1(t) can have values of the order of 1 kV. They are damped by a mechanical gate in connection with three electronical ones. The apparatus is able to measureH z (t) without an influence ofH Ho. In the case in point its sensivity is limited to 1.2 A/m (15 mOe) with an error of less than 1%.
Notes:
Übersicht Der DachverlaufH z (t) eines trapezförmigen MagnetfeldimpulsesH H (t) mit einer Länge von ca. 3 ms und einer maximalen AmplitudeH Ho=35,8·106 A/m (450 kOe) wird mit Spule und Integrator dadurch gemessen, daß man die von der Spule abgegebene Spannungu 1(t) nur während der Dauer des Dachs integriert. Dagegen wird während der Flanken des Impulsesu 1(t) unterdrückt.u 1(t) erreicht während dieser Zeit Werte von der Größenordnung 1 kV. Diese werden mit einer mechanischen Torschaltung in Verbindung mit drei elektronischen gedämpft. Das Gerät erlaubt es deshalb,H z (t) unabhängig vonH Ho zu messen. Im vorliegenden Fall lassen sich Dachschwankungsbreiten bis herab zu 1, 2 A/m (15 mOe) mit weniger, als 1% Fehler nachweisen.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF01459970