ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 18 (1979), S. 2956-2961 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 23 (1978), S. 231-234 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical & engineering data 22 (1977), S. 402-408 
    ISSN: 1520-5134
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1520-6904
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 316 (1979), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 12 (1979), S. 790-798 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Dead-time ; log ts=f(C) ; Retention index calculation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung In der vorliegenden Arbeit wird eine Methode zur Retentionsindex-Bestimmung beschrieben, die von einem kubischen Zusammenhang zwischen Bruttoretentionszeit-Differenzen der Referenzhomologen und der Kohlenstoffzahl ausgeht. Hieraus ergeben sich direkt die Nettoretentionszeiten. Der Fehler der Totzeitbestimmung entfällt bei dieser Methode. Mit den so gewonnenen Nettoretentionszeiten erhält man über einen kubischen Zusammenhang zwischen 1g ts=f(C) die Retentionsindices. Extrapolationen und Interpolationen sind über 300 Retentionsindexeinheiten mit einem mittleren Fehler von ±0,02 Retentionsindexeinheiten möglich. Das Verfahren bietet sich für eine automatische Berechnung der I-Werte mittels on-line-Datenverarbeitung an.
    Notes: Summary The method for the calculation of retention indices described here is based on a third order relationship between the logarithm of differences of unadjusted retention times of homologues and the carbon number. From this adjusted retention times are directly calculated. A determination of the dead-time is not necessary thus avoiding the errors connected with this factor. A cubic equation for the logarithm of the adjusted retention time lg ts as a function of carbon number Cn is used for the retention index calculation. Extrapolations and interpolations can be done over a range of 300 index units with an average deviation of ±0.02 i.u.. The method offers the possibility of an automated on-line calculation of retention indices by computer merely on the basis of unadjusted retention times.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index calculation ; lg ts=f(C) ; Dead-time ; Complex mixtures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die bisher in der Literatur beschriebenen Verfahren zur Retentionsindex-Bestimmung beruhen auf einem linearen Zusammenhang zwischen dem Logarithmus der Nettoretentionszeit lg ts und der Kohlenstoffzahl C der n-Alkane. Wie genaue Meßwerte für Retentionszeiten zeigen, ist die Funkton lg ts=f(C) nicht streng linear. Die Krümmung des Funktionsbildes bedingt, daß lineare Regressionsmethoden, sowie auch die Methode nach Kovats, es nicht erlauben, extrapolativ sowie über weite Retentionsbereiche interpolativ I-Werte zu berechnen. In dieser Arbeit werden Retentionsindices aufgrund eines kubischen Zusammenhanges zwischen lg ts und der Kohlenstoffzahl ermittelt. Die hierzu notwendige Totzeit tm wird aus den Differenzen der Bruttoretentionszeiten der Referenzhomologen ermittelt.
    Notes: Summary Methods of retention index calculation described in the literature have been based on a linear relationship between the logarithm of the adjusted retention times lg ts and the carbon numbers C of n-alkanes. Exact measurements of the retention times of n-alkanes show that the relationship lg ts=f(C) is in fact not strictly linear. Correct extrapolative or interpolative calculations of retention indices over a wide retention range are therefore impossible when using the original formula as given by Kovats or methods based on a linear regression concept. The method of retention index calculation presented here is based on a cubic relationship between lg ts and carbon number allowing extrapolative or interpolative calculations. The hold-up time (tm) is calculated on the basis of differences of retention times of the reference homologues.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 97-107 
    ISSN: 1618-2650
    Keywords: Best. von Biphenylen, polychlorierte, Pesticide, chlorhaltig in Fisch ; Chromatographie, Gas ; Capillar, Persistenz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Besides 83 structurally defined trichloro- to octachloro-biphenyls (PCB), the following chlorinated pesticides have been identified in fish liver oil (DAB 6) and fish liver extracts: HCB;α-HCH;γ-HCH; 2,4′-DDE; 4,4′-DDE; 2,4′-DDT; 4,4′-DDT; 2,4′-DDD; 4,4′-DDD; dieldrin; endrin. By analysing constant relative amounts of PCB-components present only in defined technical PCB-mixtures, the original PCB-pattern in environmental samples could be calculated. A mixture of Clophen A 60/Clophen A50 or of Aroclor 1260/Aroclor 1254 of 2.2∶1 gives the best fit. The constant ratio of four octachloro-biphenyls in technical mixtures and environmental samples as well requires the assumption of complete environmental stability of these compounds despite of any thinkable differences in environmental pathways. This assumption of environmental persistency is supported by a degree of degradation up to 80% of the calculated input observed for some higher chlorinated PCB-components, e.g. 2,2′,3,4,5′,6-hexachloro-biphenyl. Correlating the amount of each identified PCB-component to the octachloro-biphenyl as the internal standard, a correlation of the degradation with the PCB-substitution pattern is possible. Persistency is observed, if vicinal hydrogens are missing or a 4-position is chlorinated. A 4,4′-disubstitution favours persistency most.
    Notes: Zusammenfassung Neben 83 strukturell definierten Trichlor- bis Octachlor-biphenylen (PCB) wurden folgende chlorierte Biocide in Lebertran (DAB6) und Fischleberextrakten identifiziert: HCB;α-HCH;γ- HCH; 2,4′-DDE; 4,4′-DDE; 2,4′-DDT; 4,4′-DDT; 2,4′-DDD; 4,4′-DDD; Dieldrin; Endrin. Aus den Verhältnissen von nur in PCB-Produkten mit bestimmtem Chlorierungsgrad vorkommenden, schwer abbaubaren PCB-Komponenten konnte die ursprünglich in die Umwelt gelangte Zusammensetzung der PCB berechnet werden: eine Mischung aus Aroclor 1260/Aroclor 1254 (Monsanto, USA) oder Clophen A 60/Chlophen A 50 (Bayer, Deutschland) im Verhältnis 2,2∶1 ergibt die beste Näherung. Aus dem in technischen Produkten und den Umweltproben gleichen relativen Vorkommen von vier Octachlor-biphenylen muß auf deren völlige Stabilität unter Umweltbedingungen geschlossen werden. Diese Annahme wird durch den Abbau von bis zu 80% des ursprünglichen Gehalts anderer hochchlorierter Biphenyle, wie des 2,2′,3,4,5′,6-Hexachlor-biphenyls, gestützt. Wird das Vorkommen der identifizierten Chlorbiphenyle, auf die als persistent angenommenen Octachlor-biphenyle als internen Standard bezogen, ergibt sich eine klare Persistenz-Abbau-Beziehung zu dem PCB-Substitutionsmuster. Persistenz ist gegeben bei fehlenden vicinalen Wasserstoffatomen oder 4-Chlorsubstitution, wobei die 4,4′-Di-Substitution die Persistenz am stärksten fördert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Analyse von Umweltmaterial, Pesticiden ; Chromatographie, Gas ; Capillar-, Ident. von Einzelkomponenten in komplexen Gemischen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Der Vergleich von präzise bestimmten Retentionsindices von Probe- und Referenzsubstanzen in der hochauflösenden Capillar-Gas-Chromatographie stellt eine aussagekräftige Methode der Identifizierung von Einzelkomponenten in komplexen Gemischen dar. Neben der Konstanz der GC-Parameter erfordert die präzise Bestimmung von Retentionsindices eine sehr genaue Bestimmung der Netto-Retentionszeiten. Insbesondere ist bei Anwendung einer Totzeitberechnung auf der Basis einer erzwungenen Linearisierung der log t s/Homologenzahl-Beziehung auf eine sehr genaue Retentionszeitmessung zu achten. Die Reproduzierbarkeit von präzise bestimmten Retentionsindices hängt von der Konstanz der Polarität und von der Adsorptivität der Capillarsäule ab. An ausreichend desaktivierten und konditionierten Hochleistungs-Capillarsäulen (TZ≥40) können unter der Voraussetzung einer Retentionszeit-Meßgenauigkeit von besser als 0,05% Retentionsindices über einen Zeitraum von mehreren Wochen innerhalb ±0,15 Indexeinheiten reproduziert werden. Eine Übertragung des n-Alkan bezogenen Retentionsindex-Konzeptes auf die homologe Reihe der n-Allkyl-trichloracetate (ATA) ermöglicht die Verwendung des Elektroneneinfang-Detektors (ECD) zur präzisen RetentionsindexBestimmung als Methode einer zuverlässigen Identifizierung von Substanzen im Picogrammbereich.
    Notes: Summary High resolution glass-capillary gas chromatography can be used as a powerful identification tool for single components in complex mixtures, when the matching of retention indices of reference compounds with those found in the sample is based on precise measurements. Besides the constancy of the GC-parameters high precision measurements of retention indices require an accurate determination of net retention times. Special care has to be taken for an accurate measurement of retention times when using a dead-time calculation on the basis of an enforced linearisation of the log t s/homologues-number relationship. The reproducibility of precise retention-index determinations strongly depends on the constancy of the polarity and on the adsorptivity of the capillary column. Provided a sufficiently deactivated and conditioned high performance capillary column (separation number ≥40) and an accuracy of retention-time measurement of better than 0,05 % retention indices can be reproduced within ±0.15 i.u. over a period of several weeks. A conversion of the n-alkane based retention-index concept to the use of the homologous series of n-alkyl-trichloro-acetates (ATA) allows the use of the electron-capture detector (ECD) for precise retention-index determinations for a reliable identification of compounds in the picogram range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 395-399 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Retention index determination, reproducibility and error propagation ; Retention time measurement of ±0.01% necessary for retention index reproducibility of ±0.05 units ; Error propagation calculation program for pocket calculator given (HP 67) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Precise evaluation of the chromatographic data by means of the relative retention will allow the full use of the resolution achieved by capillary columns. In practice, retention-index determination is best suited for this purpose. The reproducibility of retention-index determination strongly depends, among other factors, on the accuracy of retention time measurement. A reproducibility of ±0,05 i.u. can be easily achieved with modern gas chromatographic equipment, provided the retention times can be measured with an accuracy of at least ±0.01%. This can be shown by error propagation analysis of retention-index calculation performed with the aid of a programmable pocket calculator.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...