ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 51 (1979), S. 1651-1654 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 47 (1975), S. 1429-1432 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 49 (1977), S. 45-48 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine einfache Mikromethode zur Bestimmung von Hydrazinen mit einer kupferionen-selektiven Elektrode wurde beschrieben. Sie beruht auf der direkten potentiometrischen Titration in ammoniakalischer Lösung mit Cu(II)ionen bei pH 9,5±0,2 bei Zimmertemperatur. N-förmige Kurven mit gut ausgebildeten Spitzen bei Molverhältnissen 1∶1 und 1∶2 wurden erhalten, wahrscheinlich auf Grund der Bildung von Mono- bzw. Dihydrazinatkomplexen des Kupfers. Verschiedene Alkyl- und Arylhydrazine und deren Salze wurden zu 99,4% mit einer Standardabweichung von ±0,4% wiedergefunden. Die Reaktion der Hydrazine mit Fehlingscher Lösung wurde ebenfalls durch Messung des entstandenen Cu(I) mit der erwähnten Elektrode untersucht.
    Notes: Summary A simple micromethod is described for the determination of hydrazines using the copper ion-selective electrode. The method is based on direct potentiometric titration of the sample in ammoniacal solution of pH 9.5±0.2 with copper(II) ions at room temperature. N-Shaped curves with well-defined inflections at 1∶1 and 1∶2 molar ratios are obtained. This is probably due to the formation of copper monohydrazinate and copper dihydrazinate complexes. Various alkyl and aryl hydrazines and hydrazine salts have been satisfactorily analyzed with an average recovery of 99.4% and a relative standard deviation of ±0.4%. The reaction of hydrazines with Fehling's solution followed by measuring the copper(I) oxide formed using the copper ion-selective electrode also has been investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung vonp-Benzochinonen werden diese mit Natriumchlorid oder Natriumbromid in 18N Schwefelsäure umgesetzt und das restliche Halogenidion potentiometrisch mit einer Chlorid- oder Bromidelektrode titriert. Dabei werden durchschnittlich 98% gefunden. Dieses Verfahren eignet sich nicht für vollständig substituierte Chinone. Die jodometrische Bestimmung von Chinonen nach Umsetzung mit Kaliumjodid und Schwefelsäure durch Titration des freigesetzten Jods mit Thiosulfat unter Verwendung eines Platin/Jodid-Elektroden-Systems wurde ebenfalls beschrieben. Chinone, die mit elektronenabweisenden Gruppen substituiert sind, müssen vor ihrer Bestimmung sulfoniert werden. Durchschnittlich werden 99% gefunden.
    Notes: Summary Simple and selective methods for the microdetermination ofp-benzoquinones are described. Quinones are reacted with sodium chloride or sodium bromide in 18N sulphuric acid followed by potentiometric titration of the residual excess halide ion with silver nitrate using the chloride or bromide electrode and Gran's plot. The average recovery is 98%. These procedures are not applicable to the determination of fully substituted quinones. Iodometric determination of quinones, after reaction with KI and H2SO4, by titration of the liberated iodine with sodium thiosulphate using the platinum/iodide electrode system is also described. Quinones substituted with electron-repelling groups require sulphonation prior to their determination. The average recovery is 99%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zweiwertiger Schwefel in verschieden strukturierten aliphatischen Verbindungen wie Thiolen, Sulfiden, Disulfiden und Thiocarbonylverbindungen, läβt sich durch Umsetzung mit festem Kaliumhydroxid bei 250–280° C durch 10 min und Zugabe von Alkaliplumbit bestimmen, wobei Bleisulfid in stöchiometrischer Menge gebildet wird. Der Überschuß an Bleiionen wird gemessen: a) durch Atomabsorptionsspektrometrie bei 217 nm; b) durch potentiometrische Titration mit ÄDTA bei pH 4,6 mit einer bleiionenspezifischen Elektrode; oder c) durch visuelle Titration mit ÄDTA, Urotropin als Puffer und Xylenolorange als Indikator. Ein durchschnittliches Ergebnis von 99% und eine mittlere Standardabweichung von 0,9% sind bei Einwaagen von wenigstens 2 mg erreichbar. Zweiwertiger Schwefel in vielen aromatischen Verbindungen, vier- und sechswertiger Schwefel sowohl in aliphatischen als auch in aromatischen Verbindungen stört nicht.
    Notes: Summary Divalent sulphur in structurally different aliphatic compounds including thiols, sulphides, disulphides and thiocarbonyls is selectively determined by reaction with solid potassium hydroxide at 250–280° for 5–10 min, followed by addition of alkali plumbite whereby lead sulphide is stoichiometrically formed. The excess lead ions are measured by: (a) atomic absorption spectrometry at 217 nm; or (b) potentiometric titration with EDTA at pH 4.6 using the lead ion selective electrode; or (c) visual titration with EDTA using urotropine buffer and Xylenol Orange indicator. An average recovery of 99%, and a mean standard deviation of 0.9% are obtainable with samples down to 2 mg. Divalent sulphur in many aromatic compounds, and tetra- and hexa-valent sulphur in both aliphatic and aromatic compounds do not interfere.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 63 (1975), S. 165-170 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei der Zersetzung einiger gem-Dinitrilo-Reiz- und Tränengase durch Elektronenstoß entstehende Reaktionsprodukte wurden beschrieben. Die Massenspektren der Benzal-,o-Chlor- undm-Nitromalonitrile zeigen einige gemeinsame Charakteristika, die zu deren Identifizierung herangezogen werden können. Diese sind: a ein Basepeak für das atom- oder gruppensubstituierte Molekülion; b ein intensiver diagnostischer Peak bei m/e-Werten von 76 und 77 entsprechend C2H(CN)2 und C2(CN)2 neben anderen CN-haltigen Bruchstücken und c der Ablauf von Umwandlungsreaktionen, die zur Bildung von Phenylcyanid führen.
    Notes: Summary Reaction products obtained during the decomposition of somegem dinitrilo sneeze and tear gases upon electron-impact are described. The spectra of benzal,o-chloro, andm-nitro malonitriles show some common characteristics which can be used for identification and characterization of these compounds. These are: (a) a base peak at [M-substituted atom or group]+; (b) diagnostic intense peak at m/e 76 and 77 due to C2H(CN)2 and C2(CN)2 besides other cyano fragmentation products; and (c) rearrangement reaction lead-ing to the formation of phenyl cyanide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Thiocarbonyl- und Thiolgruppen in organischen Verbindungen werden mit Hilfe der Reaktion mit 1-n Jod in Tetrachlorkohlenstoff in Gegenwart von Pyridin bestimmt, wobei 4 bzw. 1 Jodidäquivalente gebildet werden. Diese werden in wäßriger Phase potentiometrisch mit Silbernitrat unter Verwendung der selektiven Silber/Sulfid-Elektrode titriert. Die Ergebnisse bei Einwaagen bis herunter zu 70μg betragen durchschnittlich 98,6%. Ungesättigte Gruppen stören nicht. Die Bestimmung der Jodidionen mit jodidselektiver Elektrode unter Anwendung der bekannten Zugabetechnik führt zu Ergebnissen mit einem absoluten Fehler von 2%.
    Notes: Summary Thiocarbonyl and thiol groups in organic compounds are determined by reaction with 1N iodine in carbon tetrachloride in the presence of pyridine, whereby 4 equivalents and 1 equivalent of iodide ion are quantitatively released per group, respectively. The iodide ions in an aqueous extract are potentiometrically titrated with silver nitrate using the solid-state silver/sulphide selective electrode. The results obtained with samples down to 70μg show an average recovery of 98.6% and no interferences are caused by unsaturated functions. Measurement of the iodide ion using the iodide ion-selective electrode and the known addition technique gives results with an absolute error of 2%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 65 (1976), S. 521-526 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Einfache Mikromethoden für die Bestimmung der Azogruppe in organischen Verbindungen durch Reaktion mit Eisen (II) in saurem und alkalischem Medium wurden angegeben. Für ein „Mol“ Azofunktion werden 4 Äquivalente Fe(III) gebildet und mit Titan(III) gegen Ammoniumthiocyanat als Indikator titriert. Ein gasometrisches Verfahren beruht auf der Reduktion zu Aminen mittels Zinkpulver und Salzsäure und nachfolgender Desaminierung mit Salpetersäure, wobei 2 Mole N2O pro „Mol“ Azofunktion freigesetzt werden.
    Notes: Summary Simple micromethods are described for the determination of the azo group in organic compounds by reduction with iron(II) in acidic and alkaline media. Four equivalents of iron(III) are produced per mole of the azo function and are titrated with titanium(III) using ammonium thiocyanate as indicator. A gasometric method is also described which is based on reduction of the compounds into the amines by zinc powder and hydrochloric acid, followed by de-amination reaction with nitric acid whereby two moles of nitrous oxide gas is liberated per mole of the azo function.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 274 (1975), S. 375-377 
    ISSN: 1618-2650
    Keywords: Best. von Lysozym, Muramidase ; Rotationsdispersion ; Mikrobestimmung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method is described for microdetermination of lysozyme enzyme based on the optical properties of the molecule. The optical rotatory dispersion spectrum of lysozyme in 0.1 N HCl shows a maximum rotation at 232 nm strictly proportional, in linear relation, to lysozyme concentration ranging from 10 to 500 μg. The results show an average recovery of 98.9%, the maximum absolute error being ±2%. The effect of various solvents on the nature of the spectra is also described.
    Notes: Zusammenfassung Das Rotationsdispersionsspektrum von Lysozym in 0,1 N HCl weist ein Rotationsmaximum bei 232 nm auf. Die Rotationswerte sind von 10–500 μg der Lysozymkonzentration linear proportional. Die durchschnittliche Wiederfindensrate beträgt 98,9 %, der maximale Fehler ±2 %. Der Einfluß verschiedener Lösungsmittel auf die Spektren wird diskutiert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...