ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Polymer and Materials Science  (1)
  • METEOROLOGY AND CLIMATOLOGY
  • Meteorology and Climatology
  • Wiley-Blackwell  (1)
  • 1975-1979  (1)
Sammlung
Schlagwörter
  • Polymer and Materials Science  (1)
  • METEOROLOGY AND CLIMATOLOGY
  • Meteorology and Climatology
  • Chemistry  (1)
Verlag/Herausgeber
  • Wiley-Blackwell  (1)
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 859-869 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Monomer losses for two self-curing acrylic cements were similar via laboratory serial weighing experiments. Both the P/L ratio and mixing duration substantially influenced subsequent monomer losses, but ambient temperature variation during mixing had little effect. Greater losses were encountered during the mixing and setting intervals than during the molding interval. Patient potential exposure to monomer occurs during the molding and setting intervals; therefore, handling procedures reducing losses in these intervals are important to the surgeon.The least monomer loss during both molding and setting occurred at the manufacturers' recommended P/L ratio, which strongly indicated the need to mix all contents supplied. Mixing loss increased with amount of spatulation. However, once the mass was well mixed (about 300 steady spatulations), no further decreases in the molding and setting interval losses were promoted by overmixing. Because of the lower monomer loss rate during the molding interval, postponed cement insertion may not be warranted in light of losing mechanical locking efficiency. The actual ramifications of a threefold reduction in potential patient exposure (3.5 down to 1.2 wt % of total monomer) via modified handling techniques have not yet been clinically evaluated.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...