ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The primary structures of mammalian glucagon, secretin, vasoactive intestinal peptide (summarized in rf. 15), gastric inhibitory peptide16 and the C-terminal part of the possible glucagon prohormone17, glicentin18, were compared with the structure of human plasma prealbumin. The hormones are ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 3409-3423 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Thermo-oxidative degradation of low density polyetylene (LDPE) at a low degree of volatilization (about 4%) at 264-289°C was studied. Gas chromatography - mass spectrometric analysis was used to separate and identify the products of LDPE decomposition. Altogether 44 compounds representing hydrocarbons, alcohols, aldehydes, ketones, acids, cyclic ethers, cyclic ethers, cyclic esters, and hydroxycarboxylic acids were identified. Sixteen oxygen-containing products were quantified. Among the components identified, the fatty acids and aldehydes predominated. The most abundant product was formic acid. The mechanism of formation of the degradation products is discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 27 (1982), S. 2539-2551 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Thermal oxidation of isotactic polypropylene (PP) at 220 and 280°C in air was studied. Gas chromatography-mass spectrometric analysis was used to separate and identify the volatile products of PP oxidation. Twenty-three products were identified and 15 substances were quantified. The aldehydes are the principal products formed, followed by ketones, acids, and alcohols. The main organic product quantified was acetaldehyde. The volatile organic products formed constitute about 3% of the amount of water formed. The relative amounts of the most volatile products formed in the range 220-280°C are practically independent on the temperature of oxidation. The mechanism of formation on the oxidation products is discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Thermal oxidation of isotactic polypropylene films at 120-280°C in air was studied. Separation and identification of the volatiles formed was carried out by gas chromatography-mass spectrometry. Sixteen products were tentatively identified for the first time. Altogether, 50 compounds representing hydrocarbons, ethers, alcohols, aldehydes, ketones, and acids are reported. Oxygen deficiency is manifested in diffusion-limited products of olefines, dienes, and aromatic compounds. The relative amounts of acetaldehyde and acetone are almost temperature independent in the range of 120-280°C. This indicates a similarity of oxidative degradation of the polymer in a broad temperature range. Addition of an antioxidant to the polymer depresses the evolution of the main volatiles by 9-10 times at 280°C. The relative amounts of the volatiles formed are, nevertheless, the same as for the polymer without an antioxidant. The mechanism of formation of the degradation products is discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1980), S. 331-333 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectra of pyridine-2-, -3-, and -4-amidoxime and their O-trimethylsilyl derivatives have been investigated. Also included in this study were the deuterated derivates. Main pathways of fragmentation of these compounds have been proposed. A comparison with the mass spectra of the corresponding pyridine aldoximes has been made.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 185-190 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Mass spectrometry ; Dynamic headspace ; Deans switching ; Cold trap ; Reinjection ; Polymers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An experimental method for the analysis of volatile organic compounds in polymers is described. The technique involves dynamic headspace sampling, collection, and concentration of the volatiles in a cold trap, followed by capillary column gas chromatography/mass spectometry. Flow switching is carried out by the Deans switching technique. Four technical polymers used as pharmaceutical packaging materials have been analyzed in order to demonstrate the method.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 265-268 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the determination of unconjugated terbutaline in plasma. The assay is based on gas chromatography chemical ionization mass spectrometry with ammonia as the reagent gas. Terbutaline and a deuterium labelled internal standard were isolated from plasma by ion exchange chromatography followed by extraction into t-butanol. Quantitation was performed by selected ion monitoring of the [MH]+ions m/z 442 and m/z 448 of the tri-O-TMS derivatives of terbutaline and the internal standard, respectively. Silylation was carried out in the presence of pyridine at room temperature and was complete within one minute. The overall recovery of terbutaline in the procedure was estimated at about 80%. Measurement of terbutaline down to 0.1 ng ml-1 in 4 ml of plasma is possible with a coefficient of variation of 8.6%. Day-to-day variation was found to be 6.0% at a level of 3.26 ng ml-1.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 236-244 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Rotary valve ; Cold trap ; Reinjection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes a cold trap/reinjection system for capillary columns which utilizes a flow switching rotary valve. Sample enrichment is performed in a liquid nitrogen-cooled glass trap attached to the valve. Evaporation of enriched compounds is carried out with the aid of an electric heating coil. Parameters such as cryogenic trapping efficiency, reinjection rates, transference of sample, and adsorption, as well as overall performance, are examined. In addition, a comparison is made between the cold trap/reinjection technique and injection with a gas-tight syringe.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 22 (1984), S. 471-474 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A newly constructed far-infrared laser interferometer was used to measure the birefringence of 1-mm-thick injection-molded high-density polyethylene test bars, manufactured at unusually high molding pressures. The long wavelength used, 70.5 μm, allowed nondestructive tests to be made, demonstrating the usefulness of far-infrared techniques for probing crystalline polymers. The birefringence was shown to increase with increasing molding pressure, supporting the belief that molecular orientation increases with increasing molding pressure. The tensile modulus was also measured and was found to increase linearly with molding pressure.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...