ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Basel : Wiley-Blackwell
    Die Makromolekulare Chemie, Rapid Communications 1 (1980), S. 101-104 
    ISSN: 0173-2803
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Basel : Wiley-Blackwell
    Die Makromolekulare Chemie, Rapid Communications 1 (1980), S. 341-343 
    ISSN: 0173-2803
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: FT-IR spectroscopic studies have been performed in an attempt to elucidate the nature of the specific interactions occurring in miscible poly(∊-caprolactone) (PCL)-poly (vinyl chloride) (PVC) blends. Studies of low molecular weight analogues, polymer/solvent mixtures and blends of PCL and α-deuterated PVC are presented. The results strongly suggest that a hydrogen bonding type of interaction between the carbonyl bond of PCL and the α-hydrogen of PVC exists in compatible PCL-PVC blends.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 24 (1982), S. 1773-1788 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Alcohol dehydrogenase has been covalently attached to the surfaces of nylon stir rods. Several rod types have been evaluated in terms of their mixing efficiency and enzyme loading. Fluorometric monitoring of the rate of conversion of NAD to NADH serves as a measure of the reaction rate under varying conditions. The rate of reaction of the enzyme stir rods has been evaluated in terms of RPM, buffer concentration, NAD reagent concentration, and pH. The rate of reaction is seen to reach a plateau at higher stir rates, indicating a lack of diffusional hindrances. The reaction rate also begins to level off at phosphate buffer concentration of 0.1M to 0.15M. Saturating conditions are reached at an NAD concentration of 2.5mM. The optimum pH is found to be 9.0. The Stability of the covalent bond between the enzyme and the nylon has been assessed by comparing the bond strength to the energies of various disruptive forces to which the enzyme is exposed. Centrifugal, drag, and shear forces are shown to be insufficient to cause rupture of the bond. The stability to the immobilized enzyme preparation has been investigated under varying conditions of immobilization and use. No effect on activity loss was found for rotation rate or for continuous versus intermittent use. It was found that enhanced stability occurred for hydrolytic cleavage of the nylon, using nitric acid, as compared to nonhydrolytic cleavage. Hydrolytic cleavage also led to some degree of adsorption of the enzyme to the surface of the nylon. Thus, the possibility of increased stability to multipoint attachment of the enzyme is discussed. Possible cause of activity loss are discussed, as well as the extension of the enzyme stir rod to use in scale model reactor studies.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have developed a reproducible model of granuloma formation in the mouse lung using a narrow size range (45-53 μm) of divinyl benzene copolymer beads as a standard test material. Approximately 10,000 beads are given by intravenous injection into the tail veins of mice whence they embolize to the lung and incite granuloma formation. This delivery system eliminates the superimposed inflammatory reaction due to trauma that occurs when materials are directly implanted at the test site by surgical incision. Granuloma size was quantitated at intervals from 3 h to 6 weeks by tracing mid-bead granuloma areas on the ground glass screen of a light microscope at a known magnification and measuring the areas with a digitizer interfaced with a microcomputer programmed to prepare histograms and to merge data from replicate experiments. At 3 h only a few polymorphonuclear leukocytes could be observed adhering to the beads. At 48 h, the time of maximum granuloma size (mean area = 750l μm2), the granulomas consisted of both polymorphonuclear and mononuclear leukocytes. After 6 weeks, the granulomas were smaller, composed predominantly of mononuclear leukocytes and had a mean area of 2893 m̈m2. This model system allows the analysis of a large number of measurements, is reproducible, and provides a useful method for comparing the hosts' inflammatory response to a variety of potential biomaterials, as well as for determining the effectiveness of anti-inflammatory drugs.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...