ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (10)
  • 42.75
  • 2000-2004  (2)
  • 1980-1984  (8)
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 11 (1984), S. 132-141 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability and the present limitations of the laser microprobe mass analyser LAMMA®-500 as an instrument for the structural analysis of higher molecular weight, non-volatile, bio-organic compounds (≤2000 u) were investigated. For this purpose mass spectra of various synthetic and natural compounds representing cell wall components of Gram-negative bacteria, e.g. phospholipids and lipid A-like molecules were studied. In several cases these spectra exhibited relatively simple and interpretable patterns with a prominent quasi-molecular ion originating from alkali attachment. For one group of the compounds studied - synthetic lipid A-like molecules containing a phosphate moiety - the spectra were rather complicated and lacked pronounced quasi-molecular peaks. Possible reasons for this observation are discussed.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1980), S. 456-458 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Electron impact spectra of thermolysis products of organic salts heated in the ion source of a mass spectrometer may give rise to organic ions corresponding to the cation of the salt. Field ionization mass spectrometry has been used as a facile method for detemining whether such an ion is due to ionization of the corresponding radical present in the gas phase, or to an electron impact induced fragmentation of a reaction product of higher mass. By comparison of the electron impact and field ionization spectra of a series of N-methyl pyridinium, tropylium and 1,2-dithiolylium salts it has been found possible to identify the radicals formed thermolytically, when present.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1980), S. 38-40 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The compounds Pt3(CO)3[P(C6H5)3]4 molecular weight 1717, Pt4(CO)5[P(C6H5)3]4 molecular weight 1968 and Pt5(CO)6[P(C2H5)3]4 molecular weight 1615 are thermally labile and are slowly solvolysed by tetrahydrofuran and acetone. They cannot be analysed by means of electron impact. Field desorption, however, shows the molecular ion and [M—xCO]+· peaks.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, (HP)TLC ; Pre-chromatographic derivatization ; Quantitation of estriol, cortisol, selenium ; Biological matrix ; Water analysis ; Ready-for-use column extraction ; Fluorescence enhancement ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 109-114 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electron impact mass spectra of various methoxyhalobiphenyls have been reinvestigated. Previous findings, concerning the effect of the methoxy group upon the main fragmentation routes, have been confirmed and extended. In addition, studies of unimolecular and collision induced fragmentations of ions, using linked scan techniques, have been made. Such an approach permits the identification of substances with a minimal chromatographic separation prior to mass spectrometry. It has also led to some clarification of the fragmentation pathways leading to the observed cracking patterns.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 298-298 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Closing technique for static coating ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: Comprehensive two-dimensional gas chromatography ; thermal desorption modulator ; temperature programming ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---In comprehensive two-dimensional gas chromatography, two individual separations are coupled by means of a rotating thermal desorption modulator interface. The injection pulse introduced via the interface onto the second column should be as short as possible. Parameters affecting the modulator operation are studied. In the set-up used in this study, the temperature of the second column can be programmed independently from that of the first column. Optimization of the second-dimension separation to minimize peak broadening and maximize resolution is discussed and an elegant approach to determine second-dimension retention times using a non-constant modulation frequency is demonstrated. The high separation power of the comprehensive system is demonstrated by the analysis of technical and biota samples containing chlorinated biphenyls and toxaphene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, TLC ; Reversed phase TLC ; Chemically bonded stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An overview is given of the literature publisned in the field of thin-layer chromatography on chemically bonded phases. Aspects which merit further attention are: quantitative analysis, organic solvent selection, stationary phase characteristics, surface modification of precoated silica plates, ion-pair chromatography and correlation of thin-layer and column chromatographic data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0935-6304
    Keywords: μLC ; FID ; LC-FID ; carbohydrates ; amino acids ; alcohols ; phosphonic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The potential of the on-line coupling of microcolumn liquid chromatography (μLC) using aqueous eluents with a flame ionization detector (FID) was evaluated. An eluent-jet interface was modified to allow the efficient introduction of the eluent into the FID. The potential of the method is demonstrated by the μLC-FID determination of lower alcohols and bis(2-hydroxyethylthio)alkanes on porous and non-porous stationary phases, respectively. Flow injection analysis (FIA)-FID experiments with highly polar, thermolabile, semi-volatile and non-volatile compounds like amino acids, organic acids, alkylphosphonic acids, and carbohydrates showed the developed configuration to be a promising approach for the detection of a wide range of analytes. Compared with a nebulization interface, the eluent-jet interface showed 4-10 times higher peaks for citric acid. Detection limits by FIA for all compounds were in the range of 0.2-5 ng injected. With ribose as test compound, plots of peak height vs. amount injected showed good linearity (r2 〉 0.999) in the range of 75-12,000 μg/mL. The repeatability showed relative standard deviations of less than 5%.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 19-26 
    ISSN: 0935-6304
    Keywords: Gas chromatography, glass capillary ; Selective detection ; Nitrated polycyclic aromatic hydrocarbons ; Carbon black ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillary gas chromatography has been investigated as a method for the analysis of nitrated polycyclic aromatic hydrocarbons (nitro-PAH) using both splitless and on-column injection techniques. The nitro-PAH showed good chromatographic performance and thermal stability under the GC conditions used. Retention times and response factors of several nitro-PAH were compared to those of conventional PAH.Simultaneous flame ionization and thermionic nitrogen selective detection was used to facilitate identification of nitro-PAH in complex samples. The feasibility of the method is demonstrated on two samples of commercial carbon black. Besides 1-nitropyrene several isomeric dinitropyrenes have been identified.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...