ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 1989-01-01
    Print ISSN: 0009-5893
    Electronic ISSN: 1612-1112
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; FAME fingerprinting ; Animal fats ; Transesterification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The triglycerides of animal fats from milk, meat or cheese can also be characterized by the gaschromatographic pattern of the fatty acid methylesters (FAME) after conversion by an unsophisticated transesterification procedure. Even from the FAME pattern falsifications of commercial animal fats can be revealed by the fast separation of the FAME using a standard CW 20 M (polyethyleneglycol) capillary column. Characteristic patterns of FAME originating from different animals are shown. The patterns of the FAME from different races of the same animal are very similar, so that the characterisation according to the type of animal is not disturbed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 395-400 
    ISSN: 0935-6304
    Keywords: Multidimensional gas chromatography, GC ; Capillary columns ; Electron capture detection ; Flame ionization detection ; Double oven instrument ; Kovats indices ; Halogenated aromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A multidimensional GC-system containing two capillary columns of different polarities, operated within a double oven instrument, was used for the optimized separation of complex isomeric mixtures of various types of chlorinated aromatic compounds such as PCB, PCDD, or PCDF. Electron capture was applied parallel to flame ionization detection to obtain sensitive signals of the PCB or PCDD and the n-alkane standards required for identification by Kovats indices, respectively. Electron capture detection within a valvelessly operated MDGC system forced changes in the usual instrumental set-up, the live-switching coupling piece being located within the second oven of the double oven instrument. This oven is operated isothermally to ensure optimal and interference-free detection, for stable flow conditions within the coupling piece and for the determination of the isothermal retention indices (Kovats), which are much more suitable for identification by retention than the so-called “linear” indices.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 566-571 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns ; Cooled needle split injection ; Temperature programmed (PTV) injection ; On-column injection ; Automation ; Quantitation ; Sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Sampling techniques for practical quantitative capillary GC have to meet certain principal requirements. Both the absolute and the relative peak areas (e.g. column loads) must be reproducible with high precision and at high accuracy; discrimination of certain constituents according to their volatility should not take place on sampling. On the basis of systematic studies, the three most reliable sampling techniques used for GC analyses with the aim of achieving precise and accurate quantitative data proved to be the following: On-column, injection, splitless PTV injection, and an optimized version of split sampling called “cooled needle split” injection. The on-column technique can be optimized by using precolumns with wider internal diameters and without stationary phase coatings to overcome the problems of large liquid sampling volumes and for automation. The PTV technique should only be used in the splitless mode because discrimination cannot be suppressed completely with the split mode. All three of the techniques can be operated automatically, either to avoid “human interference”, i.e. to improve precision or for unattended operation to save man-power.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...