    Publication Date: 2011-08-24
    Description: We present a technique for introducing broad-band respiratory perturbations so that the response characteristics of the autonomic nervous system can be determined noninvasively over a wide range of physiologically relevant frequencies. A subject's respiratory bandwidth was broadened by breathing on cue to a sequence of audible tones spaced by Poisson intervals. The transfer function between the respiratory input and the resulting instantaneous heart rate was then computed using spectral analysis techniques. Results using this method are comparable to those found using traditional techniques, but are obtained with an economy of data collection.
    Keywords: Life Sciences (General)
    Type: IEEE transactions on bio-medical engineering (ISSN 0018-9294); Volume 36; 11; 1061-5
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: Each of 12 subjects set a binocularly viewed target to apparent eye level; the target was projected on the rear wall of an open box, the floor of which was horizontal or pitched up and down at angles of 7.5 degrees and 15 degrees. Settings of the target were systematically biased by 60% of the pitch angle when the interior of the box was illuminated, but by only 5% when the interior of the box was darkened. Within-subjects variability of the settings was less under illuminated viewing conditions than in the dark, but was independent of box pitch angle. In a second experiment, 11 subjects were tested with an illuminated pitched box, yielding biases of 53% and 49% for binocular and monocular viewing conditions, respectively. The results are discussed in terms of individual and interactive effects of optical, gravitational, and extraretinal eye-position information in determining judgements of eye level.
    Keywords: Life Sciences (General)
    Type: Perception & psychophysics (ISSN 0031-5117); Volume 46; 5; 469-75
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: We studied adaptation to spectral light distribution in undisturbed benthic communities of cyanobacterial mats growing in hypersaline ponds at Guerrero Negro, Baja California, Mexico. Microscale measurements of oxygen photosynthesis and action spectra were performed with microelectrodes; spectral radiance was measured with fiber-optic microprobes. The spatial resolution of all measurements was 0.1 mm, and the spectral resolution was 10 to 15 nm. Light attenuation spectra showed absorption predominantly by chlorophyll a (Chl a) (430 and 670 nm), phycocyanin (620 nm), and carotenoids (440 to 500 nm). Blue light (450 nm) was attenuated 10-fold more strongly than red light (600 nm). The action spectra of the surface film of diatoms accordingly showed activity over the whole spectrum, with maxima for Chl a and carotenoids. The underlying dense Microcoleus population showed almost exclusively activity dependent upon light harvesting by phycobilins at 550 to 660 nm. Maximum activity was at 580 and 650 nm, indicating absorption by phycoerythrin and phycocyanin as well as by allophycocyanin. Very little Chl a-dependent activity could be detected in the cyanobacterial action spectrum, even with additional 600-nm light to excite photosystem II. The depth distribution of photosynthesis showed detectable activity down to a depth of 0.8 to 2.5 mm, where the downwelling radiant flux at 600 nm was reduced to 0.2 to 0.6% of the surface flux.
    Keywords: Life Sciences (General)
    Type: Applied and environmental microbiology (ISSN 0099-2240); Volume 53; 4; 879-86
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: Ethylenediaminetetraacetic acid (EDTA), at concentrations higher than 1.0 millimolar, is phytotoxic to etiolated seedlings of Pisum sativum. Substantial vascular exudation from pea epicotyls could be obtained without tissue damage at 0.5 millimolar EDTA if the solution was buffered at pH 7.5 with sodium N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid. Treated seedlings exuded 950 micrograms (leucine equivalents) of ninhydrin-positive material per day and 870 micrograms (glucose equivalents) of anthrone-positive material per day. Amino acid analysis showed the exudate to have glutamine as the major amido nitrogen containing compound and sucrose was shown to be the major sugar. Radiolabeled tryptophan and sucrose applied to cotyledons were transferred through the epicotyl and into the collection medium. The pH profile for exudation shows half maximal exudation at pH 7.2, indicating the promotion of exudation by EDTA is probably not due simply to Ca2+ chelation.
    Keywords: Life Sciences (General)
    Type: Plant physiology (ISSN 0032-0889); 78; 734-8
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Description: Using data collected from canine models of acute myocardial ischemia, we investigated two issues of major relevance to electrocardiographic signal averaging: ECG epoch alignment, and the spectral characteristics of the beat-to-beat variability in ECG morphology. With initial digitization rates of 1 kHz, an iterative a posteriori matched filtering alignment scheme, and linear interpolation, we demonstrated that there is sufficient information in the body surface ECG to merit alignment to a precision of 0.1 msecs. Applying this technique to align QRS complexes and atrial pacing artifacts independently, we demonstrated that the conduction delay from atrial stimulus to ventricular activation may be so variable as to preclude using atrial pacing as an alignment mechanism, and that this variability in conduction time be modulated at the frequency of respiration and at a much lower frequency (0.02-0.03Hz). Using a multidimensional spectral technique, we investigated the beat-to-beat variability in ECG morphology, demonstrating that the frequency spectrum of ECG morphological variation reveals a readily discernable modulation at the frequency of respiration. In addition, this technique detects a subtle beat-to-beat alternation in surface ECG morphology which accompanies transient coronary artery occlusion. We conclude that physiologically important information may be stored in the variability in the surface electrocardiogram, and that this information is lost by conventional averaging techniques.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 14; 257-60
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-13
    Description: A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 13; 449-52
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-13
    Description: An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p 〈 .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p 〈.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 13; 525-8
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 14; 101-4
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-13
    Description: Observations from finite-element computer models, together with analytic developments based on percolation theory have suggested that subtle fluctuations of ECG morphology might serve as an indicator diminished cardiac electrical stability. With fixed-rate atrial pacing in canines, we have previously observed a pattern of alternation in T wave energy which correlated with cardiac electrical stability. We report here on a series of 20 canine experiments in which cardiac electrical stability (measured via Ventricular Fibrillation Threshold determination) was compared to a non-degenerate, multidimensional measurement of the degree of alternating activity present in the ECG complex morphology. The decrease in cardiac electrical stability brought on by both coronary artery occlusion and systemic hypothermia was consistently accompanied by subtle alternation in ECG morphology, with the absolute degree of alternating activity being significantly (negatively) correlated with cardiac electrical stability.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 12; 109-12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: In order to study transitions from normal patterns of electrical activity to abnormal patterns, such as ventricular activation, one requires a means to represent the state of myocardial electrical activation in a few parameters. Two parameters are presented here: 1) the net vorticity index (NVI) which is a measure of the net vorticity in a given region, and 2) the wavefront fractionation index (WFI), which is a measure of perturbations in the propagation of the electrical activation through the myocardium. Both parameters are topological measures in that normal propagation is condensed to a zero state, irrespective of smooth changes in wavefront orientation or shape. Several examples are demonstrated using a computer simulation of cardiac conduction. Potential applications to clinical diagnosis using experimentally obtainable data are discussed.
    Keywords: Life Sciences (General)
    Type: Computers in cardiology (ISSN 0276-6574); 13; 207-10
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...