ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 112-118 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Packed absorption columns ; Thick liquid phase films ; Natural, refinery, and reactor gas analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic system consisting of one multiport valve, two (hot-wire and flame-ionization) detectors and two analytical columns (one thick-film capillary and one packed adsorption column) is used for the analysis of gas samples containing a number of inorganic compounds (hydrogen, argon, oxygen, nitrogen, carbon monoxide, and carbon dioxide) and organic compounds. Examples include samples containing hydrocarbons up to n-nonane and benzene and toluene. The system also permits the analysis of more complicated samples containing, for example, alcohols, in addition to hydrocarbons.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 27 (1987), S. 857-860 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Polymer blends of an amorphous polyamide with poly(2vinyl pyridine) (P2VP) are presented. Differential scanning calorimetry results suggest that the system exists as a single phase material as evidenced by a single glass transition temperature. However, as illustrated by light scattering studies, this miscible binary mixture possesses a relatively low, lower critical solution temperature (LCST). Fourier transform infrared (FTIR) spectroscopic investigations indicate that the interactions occur in the blend between the N—H group of the polyamide and the —N: atom of P2VP and that the strength of the Interactions between the components is nearly identical to that occurring in the self-association of the pure amorphous polyamide. Additionally, by monitoring the concentration of “free” carbonyl groups, a quantitative measure of the number of interactions occurring in the blend is obtained.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 1801-1822 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: In this, the first paper in a series on neck formation and steady-state drawing of polymeric fibers and films under uniaxial tension, the emphasis is laid on those aspects of the mechanics of cold drawing that are not sensitive to viscoelastic effects and, therefore, can be treated by use of constitutive assumptions appropriate to elastic materials. It is here shown that a unidimensional theory which has been employed to model the mechanics of slender bars in tension6 can be derived as an approximation for three-dimensional bars and, in a sense which can be made precise, is valid to within an error of the order of the fourth power of the thickness. A particular constitutive equation for incompressible, three-dimensional, elastic materials is explored in detail and is found to yield, for such slender bars as thin fibers and wide (but thin) strips of film, equations of equilibrium whose solutions are in good qualitative accordance with the necks and drawing configurations observed in practice.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 20 (1986), S. 417-431 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Examination by light microscopy, scanning electron microscopy (SEM), and x-ray microanalysis of a clinical total artificial heart (TAH) implanted for 112 days revealed no evidence of calcification, pannus, or vegetative thrombus. A macroscopic thrombus was seen along the suture line in the right atrium but did not obstruct blood flow or valve function. Microscopic thrombi (〈0.1 mm) and evidence of microemboli were observed on the pumping diaphragm using SEM. Characterization of selected polyetherurethane (PEU) samples from the pumping bladders and housing by Curie-point pyrolysis mass spectrometry (Py-MS) revealed unexpected differences between postmortem retrieved ventricles. Although the origin of these differences could be traced back to batch-to-batch variations in the original PEU material (Biomer), the precise nature of the observed differences in chemical structure and/or composition is still unknown. Numerical comparison between pyrolysis mass spectra from PEU samples exposed to blood or tissue and unexposed samples from the same ventricles did not detect evidence of biodegradation. Continual improvements in fabrication and quality control should minimize surface imperfections and ensure polymer reproducibility; however, existing materials and design parameters appear to be adequate for continued clinical implantation.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 22 (1988), S. 119-123 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 28 (1986), S. 1241-1249 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Acoustic resonance densitometry (ARD) is reported as a method suitable not only for precise investigations into changes of specific gravity in bioreactor media but also as a technique able to provide an accurate wide range and direct determination of cellular mass in fermentation processes. It is further shown that this method can replace present optical procedures, minimizing dilution errors and operator involvement and is suitable for development as an on-line biomass monitoring system.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 33 (1989), S. 1379-1384 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Acoustic resonance densitometry (ARD) provides a highly reproducible and stable method for on-line measurement of culture biomass density. The technique provides a direct determination of changes in relative density of culture medium and cell mass. At cell concentrations higher than 106 cells mL-1this method can replace cell counts and provide a continuous measure of total cell mass. In cultures of hybridomas or U937 human lymphoma cells, the ARD value correlates well with cell number except when the average cell size changes during culture. It is argued that cell mass determined by ARD rather than cell number should be used as the basis for measurements of specific biological activity.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 20 (1986), S. 301-314 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have developed and quantitated a reproducible standardized granulomatous inflammatory reaction using divinyl copolymer beads. Approximately 10000 gas sterilized beads (43-53 μm in diameter) are injected into the tail veins of mice and embolize to the lungs where they evoke granuloma formation which is maximal at 48 h. The anti-inflammatory effects of both steroidal and nonsteroidal agents, namely, bacterial levan, hydrocortisone acetate, polyanetholsulfonate, indomethacin, acetylsalicylic acid, ellagic acid, and aminophylline were determined by comparing granuloma size in treated animals with those in untreated controls. Granulomas in paraffin sections were traced on the ground glass screen of a light microscope and the area of each granuloma measured with a digitizer-computer programmed to prepare histograms and merge data from replicate experiments. Of the agents tested, the greatest reductions in granuloma size occurred after treatment with bacterial levan (71%), hydrocorticone (70%), polyanetholsulfonate (58%), and indomethacin (55%).
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 683-700 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study examines the interaction of human low density lipoprotein (LDL) with a select group of biomedical polymers. The adsorption characteristics of LDL on cured filler-free poly(dimethyl Siloxane) (C-PDMS), Biomer, Cardiomat 610, Kraton 1650, poly(hydroxyethyl methacrylate) (PHEMA) and glass are presented. Adsorption of LDL to charged hydrophilic glass control surfaces occurred rapidly, reaching plateau concentrations within one minute (0.19 ± 0.01 ug/cm2). Adsorption of LDL to polymer surfaces appeared to be dependent upon both the polymer hydrophobicity (or apolar nature), and flexibility (or dynamic nature) at the interface. Increased surface concentrations were observed for Biomer (0.32 ± 0.01 ug/cm2) as well as other polymers which exhibited both hydrophobic and elastomeric próperties. Temperature changes between 25°C and 37°C were found to significantly influence the surface concentration of LDL on Biomer (0.16 ± 0.01 ug/cm2 at 25°C versus 0.32 ± 0.01 ug/cm2 at 37°C). A lipid core phase transition at 36°C was believed to be responsible for the temperature influence. Preliminary competitive adsorption studies of LDL with albumin (HSA) and serum on silicone surfaces suggests that LDL adsorption occurred rapidly and preferentially (0.25 ± 0.01 ug/cm2 for LDL alone; 0.33 ± 0.01 ug/cm2 for LDL + HSA; 0.15 ± 0.01 ug/cm2 LDL + serum). Preliminary studies on the role of LDL in calcification were not conclusive. It can be concluded that LDL adsorption is dependent upon polymer hydrophobicity, flexibility and temperature. Competitive adsorption experiments suggests that LDL may have substantial influence on protein adsorption.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...